logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Notifier
  6. •
  7. Power Supply
  8. •
  9. Notifier APS-6R User manual

Notifier APS-6R User manual

Other manuals for APS-6R

1

Other Notifier Power Supply manuals

Notifier ACPS-2406 User manual

Notifier

Notifier ACPS-2406 User manual

Notifier HLSPS25-XP User manual

Notifier

Notifier HLSPS25-XP User manual

Notifier FCPS-24S6 User manual

Notifier

Notifier FCPS-24S6 User manual

Notifier APS-6R User manual

Notifier

Notifier APS-6R User manual

Notifier MPS-24A User manual

Notifier

Notifier MPS-24A User manual

Popular Power Supply manuals by other brands

Monacor PS-12CCD instruction manual

Monacor

Monacor PS-12CCD instruction manual

VOLTIMA MagicBox 15 Installation and operating instructions

VOLTIMA

VOLTIMA MagicBox 15 Installation and operating instructions

Miller Auto Deltaweld 452 owner's manual

Miller

Miller Auto Deltaweld 452 owner's manual

BCP PUOUBK How to install

BCP

BCP PUOUBK How to install

HC 2210 manual

HC

HC 2210 manual

Agilent Technologies 6032A Service manual

Agilent Technologies

Agilent Technologies 6032A Service manual

Puls CT5.241 installation manual

Puls

Puls CT5.241 installation manual

OCZ ZX1250W Technical specifications

OCZ

OCZ ZX1250W Technical specifications

iseg ECH 238 manual

iseg

iseg ECH 238 manual

Agilent Technologies 6631B Service manual

Agilent Technologies

Agilent Technologies 6631B Service manual

Power XXL A Series instruction manual

Power

Power XXL A Series instruction manual

Renogy PHOENIX 300 user guide

Renogy

Renogy PHOENIX 300 user guide

HP 6200B Operating and service manual

HP

HP 6200B Operating and service manual

Epson Stylus Scan 2500 Product information sheet

Epson

Epson Stylus Scan 2500 Product information sheet

Pulsar GREEN POWER CCTV PoE POE044816 manual

Pulsar

Pulsar GREEN POWER CCTV PoE POE044816 manual

Puls MiniLine ML50.100 instruction manual

Puls

Puls MiniLine ML50.100 instruction manual

Puls AS-Interface SLA4.100 installation manual

Puls

Puls AS-Interface SLA4.100 installation manual

Kenwood PS-60 instruction manual

Kenwood

Kenwood PS-60 instruction manual

https://manuals.online logo
https://manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

DN-5952:A1 • 08/20/09 — Page 1 of 2
APS-6R
6.0 Amp Auxilary Power Supply
Power Supplies
DN-5952:A1 • E-121
GENERAL
The APS-6R is a state-of-the-art, 150 watt, switching auxiliary
power supply providing 24 VDC of filtered DC power. The
APS-6R provides two 24 VDC output circuits, each rated for
3.0 Amps in alarm and 2.0 Amps continuous. It is used for the
operation of peripheral audible/visual devices (alarm signaling
appliances) for the NOTIFIER AM2020, AFP1010, NFS-3030,
NFS-640, AFP-400, AFP-300, AFP-200, System 5000, and
System 500 control panels.
FEATURES
• Lightweight, compact design.
• “Off-line” switching technology.
• Forward topology.
• Unique design — magnetic flux-sensed converter elimi-
nates need for opto-coupler feedback.
• 120 or 240 VAC (@ 50/60 Hz) field-selectable.
• Wide input voltage range: 90 – 132 VAC, 180 – 264 VAC.
• High efficiency.
• Output circuits with overload protection.
• Built-in “brown-out” circuitry.
• Diagnostic trouble LED.
• Plug-in connector for in cabinet applications and screw ter-
minals for remote device applications.
• Shares battery and charger circuit with control panel.
• Power-limited design, per UL requirements.
• Surface-mount technology conserves panel space.
• AC Fail supervision with field-selectable delay per UL 864.
• Heavy-duty clamp-type terminals accept up to 12 AWG (3.1
mm²) wire.
CONSTRUCTION AND OPERATION
When used with the CAB-3 or CAB-4 Series (CAB-A3/-A4, -
B3/-B4, -C3/-C4, or -D3/-D4), the APS-6R mounts to a CHS-4
or CHS-4L mounting chassis. If more than one APS-6R is nec-
essary to satisfy Audible/Visual (DC) power requirements, con-
nect additional APS-6R power supplies together as described
in the Installation Instruction Manual. When used with the
AFP-200, the APS-6R mounts in the lower portion of the cabi-
net where batteries would normally mount (BB-17 required).
When used with the System 500, only one APS-6R may be
mounted in the right-most position in the cabinet.
Underwriters Laboratories requires that all Signaling Appli-
ances be approved for use with the selected control system
due to voltage operating range criteria. Use only those appli-
ances listed for use with the associated control system. Refer
to Device Compatibility Document #15378.
SPECIFICATIONS
Compatible with: AM2020, AFP1010, NFS-3030, NFS-640,
AFC-600, AFP-400, AFP-300, AFP-200, System 5000, and
System 500 control panels.
DIMENSIONS:
6.125" (15.558 cm.) high x 4.25" (11.43 cm.) wide x 3.0" (7.62
cm.) deep at protruding edge, 2.25" (5.715 cm.) deep at box
edge on opposite side.
ELECTRICAL SPECIFICATIONS
AC primary input power (TB1): 120 VAC: 120 VAC, 60 Hz,
2.5 A. 240 VAC (cut JP1): 240 VAC, 50 Hz, 1.2 A.
DC secondary input power (TB3): TB3-1 (+), TB3-2 (–).
24 VDC output power (TB2): Total 6.0 A (4.0 A continuous).
Circuit 1 (TB2-1, TB2-2; or J1): 3.0 A @ 24 VDC power-lim-
ited. Circuit 2 (TB2-3, TB2-4; or J2): 3.0 A @ 24 VDC power-
limited.
Fuses: F1 (AC supervision): 250 VAC, 4.0 A, 3 AG. F2
(battery supervision): 32 VAC, 10.0 A, 3 AG.
Trouble supervision bus: J3 output: Form-A contact (open
collector). J4 input: Form-A contact (open collector).
NOTE: J3 and J4 can be interchanged.
Loss of AC indication: Immediate indication (default); 8-
hour delay (cut JP2); 16-hour delay (cut JP2 and JP3).
MECHANICAL SPECIFICATIONS
The APS-6R in its enclosure measures approximately 6"
(15.24 cm) x 4" (10.16 cm) x 3” (7.62cm).
CABINETS FOR MOUNTING
CAB-3/CAB-4 Series: Use CHS-4 and CHS-4L chassis, for
AM2020, AFP1010, NFS-3030, NFS-640, AFP-400, AFP-300,
and System 5000 control panels.
System 500: Can mount one APS-6R if the face module
expansion card (such as an ICE-4) is not installed.
5952cov.wmf
Page 2 of 2 — DN-5952:A1 • 08/20/09
NOTIFIER® is a registered trademark of Honeywell International Inc.
©2009 by Honeywell International Inc. All rights reserved. Unauthorized use
of this document is strictly prohibited.
This document is not intended to be used for installation purposes.
We try to keep our product information up-to-date and accurate.
We cannot cover all specific applications or anticipate all requirements.
All specifications are subject to change without notice.
For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118.
www.notifier.com
Made in the U.S. A.
CAB-400AA: For AFP-300 and AFP-400 control panels.
Mounts up to one APS-6R. An option module, without expan-
sion card, is allowed.
AFP-200 backbox. Mount up to one APS-6R in the lower
position of the box (where batteries mount). A BB-17 battery
box is required.
PRODUCT LINE INFORMATION
APS-6R: 24-volt, filtered power supply (120/220 VAC input).
EOLR-1: 12/24 VDC end-of-line relay.
CHS-4: Four-module chassis.
CHS-4L: Four-module chassis (low-profile).
Agency Listings and Approvals
The listings and approvals below apply to the basic APS-6R. In
some cases, certain modules may not be listed by certain
approval agencies, or listing may be in process. Consult fac-
tory for latest listing status.
•UL: S624
•ULC: CS118/CS733/CBP696 Vol. IX
•FM: Approved (AFP-200, AFP-300/400, AFC-600, NFS-
640, AFP-1010/AM2020, NFS-3030, System 500, Sys-
tem 5000)
•CSFM: 7315-0028:190, 7165-0028:214 (NFS-640);
7165:0028:224 (NFS-3030, NFS2-3030); 7170-0028:216
(NFS-640); 7170-0028:223 (NFS-3030, NFS2-3030)
•MEA: 195-97-E Vol. II, 447-99-E (AFC-600), 317-01-E
(NFS-640), 345-02-E (NFS-3030), 232-02-E (NFS2-
3030)
APS-6R
Assembly
Mounting APS-6R to the
CHS-4 Chassis
5952assy.wmf
5952mt1.wmf
APS-6R
Assembly