Novalynx 200-WS-01B User manual

DOC 200-WS-01 UM 20210413
200-WS-01x
User Manual
WeatherPort
Wind Speed Sensors
Wind Run Sensors
Phone (530) 823-7185
Email nova@novalynx.com Website www.novalynx.com

NovaLynx Corporation
200-WS-01 Page 2 April 2021
Receiving and Unpacking
Carefully unpack all components and compare to the packing list. Notify NovaLynx Corporation
immediately concerning any discrepancy. Inspect equipment to detect any damage that may have
occurred during shipment. In the event of damage, any claim for loss must be filed immediately with
the carrier by the consignee. Damages to equipment sent via Parcel Post or UPS require the consignee
to contact NovaLynx Corporation for instructions.
Returns
If equipment is to be returned to the factory for any reason, call NovaLynx between 8:00 a.m. and 4:00
p.m. Pacific Time to request a Return Authorization Number (RA#). Include with the returned
equipment a description of the problem and the name, address, and daytime phone number of the
sender. Carefully pack the equipment to prevent damage or additional damage during the return
shipment. Call NovaLynx for packing instructions in the case of delicate or sensitive items. If packing
facilities are not available take the equipment to the nearest Post Office, UPS, or other freight service
and obtain assistance with the packaging. Please write the RA# on the outside of the box.
Warranty
NovaLynx Corporation warrants that its products are free from defects in material and workmanship
under normal use and service for a period of one year from the date of shipment from the factory.
NovaLynx Corporation's obligations under this warranty are limited to, at NovaLynx's option: (i)
replacing; or (ii) repairing; any product determined to be defective. In no case shall NovaLynx
Corporation's liability exceed product's original purchase price. This warranty does not apply to any
equipment that has been repaired or altered, except by NovaLynx Corporation, or that has been
subjected to misuse, negligence, or accident. It is expressly agreed that this warranty will be in lieu of
all warranties of fitness and in lieu of the warranty of merchantability.
Address
NovaLynx Corporation
431 Crown Point Circle, Suite 120
Grass Valley, CA 95945-9531 USA
Phone: (530) 823-7185
Email: nova@novalynx.com
Website: www.novalynx.com
Copyright © 1988-2021 by NovaLynx Corporation

NovaLynx Corporation
200-WS-01 Page 3 April 2021
CONTENTS
1 FORWARD ....................................................................................................................................................................... 4
2 INTRODUCTION ............................................................................................................................................................... 4
3 PRECAUTIONS ................................................................................................................................................................. 4
4 SPECIFICATIONS .............................................................................................................................................................. 5
5 MODEL NUMBERS AND FEATURES ................................................................................................................................. 5
5.1 Wind Run Sensors ................................................................................................................................................... 5
5.2 Wind Speed Sensors ................................................................................................................................................ 6
6 SITE SELECTION ............................................................................................................................................................... 6
7 MOUNTING OPTIONS ...................................................................................................................................................... 7
8 INSTALLATION ................................................................................................................................................................. 8
9 MAINTENANCE ................................................................................................................................................................ 8
10 FUNCTIONAL TESTS ..................................................................................................................................................... 9
APPENDIX A Tripod Dimensions ............................................................................................................................................ 10

NovaLynx Corporation
200-WS-01 Page 4 April 2021
1 FORWARD
Thank you for purchasing NovaLynx products. NovaLynx has been designing and manufacturing
weather instruments since 1988. NovaLynx represents several well-known brands of quality
manufacturers, including Gill Instruments, RM Young, Kipp & Zonen, and Vaisala. It is our hope that our
products will meet all your monitoring requirements.
2 INTRODUCTION
WeatherPort 200-WS-01 Wind Sensors are moderately priced anemometers designed for general
applications up to 125 mph (56 m/s). The sensors are easy to install and maintain. They are
constructed of injection molded thermoplastic, anodized aluminum, and stainless steel for reliable
operation in adverse environments.
The base of the sensor is designed to mount on a vertical 1.07" (27 mm)
diameter mast. If the sensor cannot be mounted at the top of the mast,
an optional side-mount boom (NovaLynx 200-153) is available.
Most versions of the 200-WS-01x sensor include 40 feet (12 m) of cable.
The cable is attached to the side of the sensor, as shown in the photo, or
it exits the base. Be aware that if the cable exits the base, it must be
threaded through the supporting mast. Cable (Side Exit)
The 200-WS-01 is a cup-style anemometer. One or more permanent magnets in the rotating cup
assembly cause a reed switch in the base to close momentarily, so that the frequency of pulses is
proportional to wind velocity, and the number of pulses is proportional to distance.
Sensors designed for monitoring wind speed output 3 pulses per revolution (3 ppr).
Sensors designed for monitoring wind run output 1 pulse per revolution (1 ppr).
3 PRECAUTIONS
Handle the sensor carefully as the cup assembly is fragile. Do not lay the sensor on its side which would
place strain on the cup assembly.
The shield wire in the sensor cable is electrically connected to the shaft holding the bearing / cup
assembly. The purpose is to bleed off static that would otherwise affect the sensor output. Therefore it
is important to earth ground the shield wire for best results.
Installations where nearby lightning strikes are likely should include a properly grounded lightning rod
above the level of the sensor, preferably on a separate tower.

NovaLynx Corporation
200-WS-01 Page 5 April 2021
4 SPECIFICATIONS
5 MODEL NUMBERS AND FEATURES
5.1 Wind Run Sensors
Wind run is the distance or length of flow of the air past a point during an interval of time. It is usually
measured in miles or kilometers. NovaLynx wind run sensors produce one switch closure per
Measurement Range 125 mph max (56 m/s max)
1.2 mph (0.54 m/s)
Except Model 200-WS-01B-TS, which has a slightly higher starting
threshold due to a characteristic of the Teflon bearing.
Speed Accuracy (3 ppr) 1 mph (0.4470 m/s) or ±3%
Speed Constant (3 ppr) 1.25 mph = 1 Hz (0.5588 m/s = 1 Hz)
960 pulses per mile (596.5 pulses per km)
0.001042 miles per pulse (0.001676 km per pulse)
Transducer Type Reed switch, magnet activated
Maximum Rating 10 mA @ 50 V (ac or dc)
Turning Radius 4 inch (10.16 cm)
40 feet (12 m), 2 conductor, 24 AWG, shielded, tinned leads
Except Model 200-WS-01C, which has 1' (0.3 m) hookup wire.
1.07 inch diameter by 0.82 inch socket (27 mm dia x 21 mm)
Note: Standard 3/4" IPS pipe is 1.05" o.d. and fits the socket.
Dimensions 4.5" H x 8.2" W x 8.2" D (12 x 21 x 21 cm)
Weight / Shipping 0.95 lbs (0.43 kg) / 2 lbs (0.9 kg)
200-WS-01x Anemometer Specification
Speed Threshold
Cable
Mounting
Distance Constant (1 ppr)
Model Pulses/Rev Cable Exit Cable Type Cable Length Feature / Use With
200-WS-01B-C1 1 Side 2-Conductor, 24 AWG 40 feet (12 meter) General Purpose
200-WS-01C 1 Bottom 22 AWG Hookup Wire 1 foot (0.3 meter) 200-2510-B, 200-2511-B
Model Pulses/Rev Cable Exit Cable Type Cable Length Feature / Use With
200-WS-01A 3 Bottom 2-Conductor, 24 AWG 40 feet (12 meter) General Purpose
200-WS-01B 3 Side 2-Conductor, 24 AWG 40 feet (12 meter) General Purpose
200-WS-01B-TS 3 Side 2-Conductor, 24 AWG 40 feet (12 meter) Teflon Bearing
200-WS-01MB 3 Side 2-Conductor, 24 AWG 40 feet (12 meter) Metal Base
Wind Run
Wind Speed
Other manuals for 200-WS-01B
1
This manual suits for next models
6
Table of contents
Other Novalynx Accessories manuals

Novalynx
Novalynx 225-HMP60A User manual

Novalynx
Novalynx 255-100 User manual

Novalynx
Novalynx 200-WS-22 User manual

Novalynx
Novalynx 200-WS-23 User manual

Novalynx
Novalynx 200-WS-03D User manual

Novalynx
Novalynx 200-WS-01B User manual

Novalynx
Novalynx 200-WS-04 User manual

Novalynx
Novalynx 200-WS-23-DP User manual

Novalynx
Novalynx 260-2520 User manual

Novalynx
Novalynx 225-WS-32THA User manual