NTI AG LinMot E14 0 Series User manual

PRELIMINARY
E14x0 Servo Controller
Installation Guide
Eine Deutsche Version kann unter http://www.linmot.com ezogen werden!
Please visit http://www.linmot.com to check for the latest version of this document!
This document applies to the following controllers:
E1400-GP-QN
E14 0-DP-QN
E1450-PL-QN
E1450-EC-QN
E1450-PN-QN
E1450-IP-QN
E1450-SC-QN

E1400 Installation Guide preliminary
© 2011 NTI AG
This work is protected by copyright.
Under the copyright laws, this publication may not be reproduced or transmitted in any form, electronic or mechanical, including
photocopying, recording, microfilm, storing in an information retrieval system, not even for didactical use, or translating, in whole or in
part, without the prior written consent of NTI AG.
LinMot® is a registered trademark of NTI AG.
The information in this documentation reflects the stage of development at the time of press and is therefore without obligation.
NTI AG reserves itself the right to make changes at any time and without notice to reflect further technical advance or product
improvement.
Document version 4.2 / FM, June 2011
Page 2/24 www.LinMot.com NTI AG / LinMot®

Preliminary E1400 Installation Guide
Table of Content
1 Important Safety Instructions.........................................................................................4
2 System Overview.............................................................................................................
3 Functionality and Interfaces...........................................................................................7
4 IP Address Selection.......................................................................................................7
5 Power Supply and Grounding........................................................................................8
Description of the connectors / Interfaces....................................................................9
6.1 X1................................................................................................................................9
6.2 X 0..............................................................................................................................9
6. X2................................................................................................................................9
6.4 X ..............................................................................................................................10
6.5 X4 .............................................................................................................................10
6.6 X7 - X8......................................................................................................................11
6.7 X9..............................................................................................................................11
6.8 X10 - X11..................................................................................................................12
6.9 X1 ............................................................................................................................12
6.10 X15 - X16................................................................................................................1
6.11 X17 - X18................................................................................................................1
6.12 X19..........................................................................................................................1
6.1 X20..........................................................................................................................14
6.14 X29..........................................................................................................................14
6.15 S5............................................................................................................................14
6.16 LEDs.......................................................................................................................15
6.17 RT BUS LEDs.........................................................................................................15
6.18 S1 - S2....................................................................................................................15
7 Error Codes....................................................................................................................1
8 Safety Wiring..................................................................................................................17
9 Physical Dimensions.....................................................................................................18
10 Power Supply Requirements......................................................................................19
11 Regeneration of Power / Regeneration Resistor......................................................19
12 Ordering Information...................................................................................................20
13 International Certifications.........................................................................................20
14 Declaration of Conformity CE-Marking......................................................................21
15 Contact Addresses......................................................................................................24
NTI AG / LinMot®www.LinMot.com Page 3/24

E1400 Installation Guide preliminary
1 Important Safety Instructions
For your personal safety
Disregarding the following safety measures can lead to severe injury to persons and
damage to material:
•Only use the product as directed.
•Never commission the product in the event of visible damage.
•Never commission the product before assembly has been completed.
•Do not carry out any technical changes on the product.
•Only use the accessories approved for the product.
•Only use original spare parts from LinMot.
•Observe all regulations for the prevention of accidents, directives and laws applicable on site.
•Transport, installation, commissioning and maintenance work must only be carried out by qualified
personnel.
•Observe IEC 64 and CENELEC HD 84 or DIN VDE 0100 and IEC report 664 or
DIN VDE 0110 and all national regulations for the prevention of accidents.
•According to the basic safety information, qualified, skilled personnel are persons who are
familiar with the assembly, installation, commissioning, and operation of the product and who
have the qualifications necessary for their occupation.
•Observe all specifications in this documentation.
•This is the condition for safe and trouble−free operation and the achievement of the specified
product features.
•The procedural notes and circuit details described in this documentation are only proposals.
It is up to the user to check whether they can be transferred to the particular applications.
NTI AG / LinMot does not accept any liability for the suitability of the procedures and circuit
proposals described.
•LinMot servo controllers and the accessory components can include live and moving parts
(depending on their type of protection) during operation. Surfaces can be hot.
•Non−authorized removal of the required cover, inappropriate use, incorrect installation or
operation create the risk of severe injury to persons or damage to material assets.
•For more information, please see the documentation.
•High amounts of energy are produced in the controller. Therefore it is required to wear personal
protective equipment (body protection, headgear, eye protection, hand guard).
Application as directed
•Controllers are components which are designed for installation in electrical systems or machines.
They are not to be used as domestic appliances, but only for industrial purposes according to EN
61000− −2.
•When controllers are installed into machines, commissioning (i.e. starting of the operation as
directed) is prohibited until it is proven that the machine complies with the regulations of the EC
Directive 98/ 7/EC (Machinery Directive); EN 60204 must be observed.
•Commissioning (i.e. starting of the operation as directed) is only allowed when there is compliance
with the EMC Directive (2004/108/EC).
•The technical data and supply conditions can be obtained from the nameplate and the
documentation. They must be strictly observed.
Transport, storage
•Please observe the notes on transport, storage, and appropriate handling.
•Observe the climatic conditions according to the technical data.
Page 4/24 www.LinMot.com NTI AG / LinMot®

Preliminary E1400 Installation Guide
Installation
•The controllers must be installed and cooled according to the instructions given in the corresponding
documentation.
•The ambient air must not exceed degree of pollution 2 according to EN 61800−5−1.
•Ensure proper handling and avoid excessive mechanical stress. Do not bend any components and
do not change any insulation distances during transport or handling. Do not touch any electronic
components and contacts.
•Controllers contain electrostatic sensitive devices which can easily be damaged by inappropriate
handling. Do not damage or destroy any electrical components since this might endanger your
health!
Electrical connection
•When working on live controllers, observe the applicable national regulations for the prevention of
accidents.
•The electrical installation must be carried out according to the appropriate regulations (e.g. cable
cross−sections, fuses, PE connection). Additional information can be obtained from the
documentation.
Operation
•If necessary, systems including controllers must be equipped with additional monitoring and
protection devices according to the valid safety regulations (e.g. law on technical equipment,
regulations for the prevention of accidents). The controllers can be adapted to your application.
Please observe the corresponding information given in the documentation.
•After the controller has been disconnected from the supply voltage, all live components and power
connections must not be touched immediately because capacitors can still be charged. Please
observe the corresponding stickers on the controller. All protection covers and doors must be shut
during operation.
Protection of persons
•Before working on the controller, check that no voltage is applied to the power
terminals:
•The power terminals U, V, W, DC+, DC-, RR+, and RR- remain live for at
least 5 minutes after disconnecting from mains.
•The power terminals L1, L2, L ; U, V, W, DC+, DC-, RR+ and RR- remain
live when the motor is stopped.
•The leakage current to earth (PE) is > .5 mA. According to EN 50178 a fixed
installation is required and a double PE connection is required.
•The heat sink of the controller has an operating temperature of > 80 °C: Contact with
the heat sink results in burns.
NTI AG / LinMot®www.LinMot.com Page 5/24

E1400 Installation Guide preliminary
2 System Overview
Typical Servo System E14x0-XX: Servo Controller, Motor and Power Supply.
Page 6/24 www.LinMot.com NTI AG / LinMot®

Preliminary E1400 Installation Guide
3 Functionality and Interfaces
E1450-PL-QN
E1450-PN-QN
E1450-SC-QN
E1450-IP-QN
E1450-EC-QN
E1430-DP-QN
E1400-GP-QN
Supply Voltage
Motor Supply x400 VAC / x480 VAC ● ● ● ● ● ● ●
Logic Supply 24VDC (22...26VDC) ● ● ● ● ● ● ●
Motor Phase Current (preliminary)
28A rms peak ●●●●●●●
4 A rms continuous (without forced cooling) ● ● ● ● ● ● ●
12 A rms continuous (with fan option EV01-E1400) ● ● ● ● ● ● ●
18 A rms continuous (cold plate 20°C) ● ● ● ● ● ● ●
Controllable Motors
LinMot P10-70x…(Motor Link C) ● ● ● ● ● ● ●
Selected motors (contact support) ● ● ● ● ● ● ●
Command Interface
CANopen ● ● ● ● ● ● ●
LinRS ● ● ● ● ● ● ●
POWERLINK ●
PROFINET ●
SERCOS III ●
ETHERNET IP ●
ETHERCAT ●
PROFIBUS-DP ●
Programmable Motion Profiles (Curves)
Up to 100 Motion Profiles ● ● ● ● ● ● ●
Programmable Command Table
Command Table with up to 255 entries ● ● ● ● ● ● ●
External Position Sensor
Incremental (RS422 up to 25 M counts/s) ● ● ● ● ● ● ●
SinCos (1Vpp differential)1●●●●●●●
Absolute (BiSS)2●●●●●●●
Synchronisation
Master Encoder In/Out
(RS422 up to 25 M counts/s) ●●●●●●●
Configuration Interface
RS2 2 ● ● ● ● ● ● ●
Ethernet 10/100 Mbit/s
(2-Port Switch integrated) ●●●●●●●
4 IP Address Selection
The default mode for acquiring an IP address is via DHCP. If no servers respond on
the connected network, the controller switches to the Ipv4 Link-Local addressing
scheme (also known as APIPA on Windows systems). This way the controller
automatically assigns itself an address within the range of 169.254.0.1 through
169.254.255.254 (Subnet Mask 255.255.0.0).
Please note that this process can take up to a minute until a valid address is
assigned to the controller.
1 Firmware support planned
2 Firmware support planned
NTI AG / LinMot®www.LinMot.com Page 7/24

E1400 Installation Guide preliminary
5 Power Supply and Grounding
In order to assure a safe and error free operation, and to avoid severe
damage to system components, all system components must be well
grounded to protective earth PE. This includes both LinMot and all
other control system components on the same ground bus.
The leakage current to earth (PE) is > .5 mA. According to EN 50178 a
fixed installation is required and a double PE connection is required.
One PE connection is on X 0, the second one is an M5 bolt on top of
the housing.
Each system component should be tied directly to the ground bus (star
pattern), rather than daisy chaining from component to component.
(LinMot motors are properly grounded through their power cables when
connected to LinMot controllers.)
Page 8/24 www.LinMot.com NTI AG / LinMot®

Preliminary E1400 Installation Guide
Description of the connectors / Interfaces
.1 X1
X1 DC Busbar/ Regeneration Resistor
DC+: DC busbar +
DC-: DC busbar -
RR+: Positive connection for Regeneration Resistor
RR-: Negative connection for Regeneration Resistor
Screw Terminals:
- Tightening torque: 0.7 - 0.8 Nm
- Use a cross-head screw driver (PH1)
- Use 60/75°C copper conductors only
- Conductor cross-section: 0.25 – 4 mm2 (depends on Motor current) / AWG 24 -12
- Stripping length 10mm
.2 X30
X30 Motor Supply Mains
L1 – L : x400 / x480VAC 50/60 Hz
PE: PE, Protective Earth
Screw Terminals:
- Tightening torque: 0.7 - 0.8 Nm
- Use a cross-head screw driver (PH1)
- Use 60/75°C copper conductors only
- Conductor cross-section: 2.5 – 4 mm2 (depends on Motor current) / AWG 24 -12
- Stripping length 10mm
.3 X2
X2 Motor Phases
W: Motor Phase W
V: Motor Phase V
U: Motor Phase U
Br+: Motor Break positive
Br-: Motor Break negative
PE: Protective Earth and Cable Shield
Screw Terminals:
- Tightening torque: 0.7 - 0.8 Nm
- Use a cross-head screw driver (PH1)
- Use 60/75°C copper conductors only
- Conductor cross-section: 0.25 – 4 mm2 (depends on Motor current) / AWG 24 -12
- Stripping length 10mm
NTI AG / LinMot®www.LinMot.com Page 9/24

E1400 Installation Guide preliminary
.4 X3
X3 Motor Encoder (Motor Link C)
1
9
2
10
11
4
12
5
1
6
14
7
15
8
case
+5V
Sin+
Sin-
Cos+
Cos-
+5V Sense
GND Sense
-
GND
-
-
-
-
Motor Link C +
Motor Link C -
shield
DSUB-15 (f) Motor Link C is a high speed serial communication protocol to the motor encoder.
.5 X4
X4 Logig Supply / IO Connection
16
15
14
1
12
11
10
9
8
7
6
5
4
2
1
Ksr +
Ksr -
Ksr f+
Ksr f-
Input SVE
Input Quickstop
I/O X4.10
I/O X4.9
I/O X4.8
I/O X4.7
I/O X4.6
I/O X4.5
I/O X4.4
I/O X4. /Brk
+24VDC Supply
GND Supply
Safety Relay Input positive
Safety Relay Input negative
Safety Relay feedback positive
Safety Relay feedback negative
Power Stage Enable (HW Enable)
Quickstop, PTC2 Input
Configurable IO, PTC1 Input
Configurable IO
Configurable IO
Configurable IO
Configurable IO, Trigger Input
Configurable IO
Configurable IO, Analog Input (configurable as high imp. Input)
Configurable IO, Brake Driver 1A
Logic Supply 22-26 VDC
Ground
Screw terminals Inputs (X4. .. X4.12): 24V / 5mA (Low Level: –0.5 to 5VDC, High Level: 15 to 0VDC)
Outputs (X4.4 .. X4.10): 24V / max.100mA, Peak 70mA (will shut down if exceeded)
Brake Output (X4. ): 24V / max.1.0A
To enable the power stage the input SVE (X4.12) and the integrated safety relay Ksr (X4.1 – X4.16) must
be correctly wired. Please refer to chapter 8 Safety Wiring.
Input X4.12: SVE (Safety Voltage Enable) must be high for enabling the power stage. If it goes low for
more than 0.5ms the PWM generation of the power stage is disabled by hardware.
To disable the internal safety features, connect X4.16 and X4.12 to +24VDC and X4.15 to GND.
Supply 24V / type. 500mA / max. 2.5A (if all outputs “on” with max. load.)
- Tightening torque: min 0.22Nm
- Screw thread: M2
- Use 60/75°C copper conductors only
- Conductor cross-section max. 1.5mm2
- Internal Fuse (F2): AT (slow blow, Schurter OMT125, 404.0118.xx, UL File Number: E41599)
CAUTION: For continued protection against risk of fire, replace only with same type and rating of fuse.
Page 10/24 www.LinMot.com NTI AG / LinMot®

Preliminary E1400 Installation Guide
. X7 - X8
X7 - X8 CMD (RS485/CAN)
1
2
X
4
5
6
7
8
case
RS485_Rx+ A
RS485_Rx- B
RS485_Tx+ Y
GND
GND
RS485_Tx- Z
CAN_H
CAN_L
Shield
RJ-45 Use twisted pair (1-2, -6, 4-5, 7-8) cable for wiring.
The built in RS485 and CAN terminations can be activated by S5.2 and S5. .
X7 is internally connected to X8 (1:1 connection)
.7 X9
X9 PROFIBUS DP (only available on E1430-DP-QN)
1
6
2
7
8
4
9
5
case
Not connected
+5V (isolated)
Not connected
Not connected
RxD/TxD-P
RxD/TxD-N
CNTR-P
Not connected
GND (isolated)
Shield
DSUB-9 (f) Max. Baud rate: 12Mbaud
NTI AG / LinMot®www.LinMot.com Page 11/24

E1400 Installation Guide preliminary
.8 X10 - X11
X10 - X11 Master Encoder IN (X10) / Master Encoder OUT (X11)
1
2
4
5
6
7
8
case
Incremental: Step/Direction:
A+ Step+
A- Step-
B+ Direction+
Z+ Zero+
Z- Zero-
B- Direction-
CAN_H CAN_H
CAN_L CAN_L
Shield Shield
EIA/TIA 568A colors:
Green/White
Green
Orange/White
Blue
Blue/White
Orange
Brown/White
Brown
RJ-45 Use twisted pair (1-2, -6, 4-5, 7-8) cable for wiring.
Master Encoder Inputs: Differential RS422, max. 25 M counts/s, 40ns edge separation
Master Encoder Outputs: Amplified RS422 differential signals from Master Encoder IN (X10)
The CAN bus can be terminated with S5.4.
All devices, which are connected to X10/X11 must be referenced to the same ground.
.9 X13
X13 External Position Sensor Differential Hall Switches
1
9
2
10
11
4
12
5
1
6
14
7
15
8
case
+5V DC
A+
A-
B+
B-
Z+
Z-
Encoder Alarm
GND
U+
U-
V+
V-
W+
W-
Shield
DSUB-15 (f) Position Encoder Inputs ( RS422):
Max Input Frequency: 25 M counts/s with quadrature decoding, 40ns edge separation
Encoder Simulation Outputs (RS422):
Max Output Frequency: 25 M counts/s with quadrature decoding, 40ns edge separation
Differential Hall Switch Inputs (RS422):
Input Frequency: <1kHz
Enc. Alarm In:
5V / 1mA
Sensor Supply:
5VDC max. 100mA / 9VDC 100mA (SW selectable)
Page 12/24 www.LinMot.com NTI AG / LinMot®

Preliminary E1400 Installation Guide
.10 X15 - X1
X15 - X1 Config Ethernet 10/100 Mbit/s
X15
X16
Internal 2-Port 10BASE-T and 100BASE-TX Ethernet Switch with Auto MDIX.
LEDs on the lower side of the device indicate “Link/Activity” per port, the upper ones
are not used.
RJ-45
.11 X17 - X18
X17 - X18 RealTime Ethernet 10/100 Mbit/s
X17 RT ETH In
X18 RT ETH Out
Specification depends on RT-Bus Type. Please refer to according documentation.
RJ-45
.12 X19
X19 System
1
2
4
5
6
7
8
case
Do not connect
Do not connect
RS2 2 Rx
GND
GND
RS2 2 Tx
Do not connect
Do not connect
Shield
RJ-45 Use adapter cable AC01-RJ45/Df-2.5-RS1 (Art.-No. 0150-2143) for configuration over RS2 2.
NTI AG / LinMot®www.LinMot.com Page 13/24

E1400 Installation Guide preliminary
.13 X20
X20 Analog In (+-10V Differential Analog Input)
1
2
4
5
6
7
8
case
Do not connect
Do not connect
Analog In -
GND
GND
Analog In +
Do not connect
Do not connect
Shield
RJ-45
.14 X29
X29 Connector for Fan Option
Spring cage terminal block for connecting the external fan option (Art. Nr. 0150-xxxx).
Output: 24 VDC / 0.4 A (Short circuit protected, current monitored)
Stripping length: 8mm
Conductor cross section: 0.2 – 1.5 mm2 (AWG 24 - 16)
.15 S5
S5 Bus Termination / AnaIn2 Pull Down
S5 Switch 6: Override Configuration Ethernet to DHCP
Switch 5: Bootstrap: Must be off for normal operation
Switch 4: CAN termination on ME (120R between pin 7 and 8 on X10/X11) on/off
Switch : CAN termination on CMD (120R between pin 7 and 8 on X7/X8) on/off
Switch 2: Termination resistor for RS485 on CMD (120R between pin 1 and 2 on X7/X8) on/off
Switch 1: AnIn2 pull down (4k7 Pull down on X4.4). Set to ON, if X4.4 is used as digital output.
Factory setting: all switches “on” except S5.5 (Bootstrap) and S5.6 (Override to DHCP)
Page 14/24 www.LinMot.com NTI AG / LinMot®

Preliminary E1400 Installation Guide
.1 LEDs
LEDs State Display
Green
Yellow
Yellow
Red
24V Logic Supply OK
Motor Enabled / Error Code Low Nibble
Warning / Error Code High Nibble
Error
.17 RT BUS LEDs
RT Bus LEDs RT Bus State Display
Green
Red
OK
Error
The use of these LEDs depends on the type of fieldbus which is used. Please see the corresponding
manual for further information.
.18 S1 - S2
S1 - S2 Address Selectors
S1 (5..8)
S2 (1..4)
Bus ID High (0 … F). Bit 5 is the LSB, bit 8 the MSB.
Bus ID Low (0 … F). Bit 1 is the LSB, bit 4 the MSB.
The use of these switches depends on the type of fieldbus which is used. Please see the corresponding
manual for further information.
NTI AG / LinMot®www.LinMot.com Page 15/24

E1400 Installation Guide preliminary
7 Error Codes
Error Codes
Error Warn EN Description
Off Warning Operation
Enabled
Normal Operation:
Warnings and operation enabled are displayed.
On ● ~2Hz
0..15 x
Error Code
High Nibble
● ~2Hz
0..15 x
Error Code
Low Nibble
Error:
The error code is shown by a blink code with “WARN” and “EN”.
The error byte is divided into low and high nibble (= 4 bit).
”WARN” and “EN” are blinking together.
The error can be acknowledged.
(e.g.: WARN blinks x, EN blinks 2x; Error Code = 2h)
● ~2Hz ● ~2Hz
0..15 x
Error Code
High Nibble
● ~2Hz
0..15 x
Error Code
Low Nibble
Fatal Error:
The error code is shown by a blink code with “WARN” and “EN”.
The error byte is divided into low and high nibble.
”WARN” and “EN” are blinking together.
Fatal errors can only be acknowledged by a reset or power cycle.
(e.g.: WARN blinks x, EN blinks 2x; Error Code = 2h)
● ~4Hz ● ~2Hz
0..15 x
Error Code
High Nibble
● ~2Hz
0..15 x
Error Code
Low Nibble
System Error:
Please reinstall firmware or contact support.
● ~0.5Hz ● ~0.5Hz On Signal Supply 24V too low:
The error and warn LEDs blink alternating if the signal supply +24V (X4.2) is
less than 18VDC.
The meaning of the error codes can be found in the
Usermanual_MotionCtrl_Software_SG5 and the user manual of the installed
interface software. These documents are provided together with LinMot-Talk
configuration software and can be downloaded from www.linmot.com.
Page 16/24 www.LinMot.com NTI AG / LinMot®

Preliminary E1400 Installation Guide
8 Safety Wiring
The E1400 Controller has internal safety functions:
•SVE (Safety Voltage enable): Fast reacting inhibition of power pulses.
•Safety relay Ksr, which supports the 15 V for the IGBT drivers. It has two
feedback contacts.
Safety Relay Ksr
Nominal voltage 24 VDC
Min. pick-up voltage at 20°C ≤ 16.8V
Drop-out voltage at 20°C ≥ 2.4 V
Coil resistance at 20°C 2'100 Ω ± 10%
Type EN 50205, type A
NTI AG / LinMot®www.LinMot.com Page 17/24

E1400 Installation Guide preliminary
9 Physical Dimensions
E1400 Series single axis controller
Width mm (in) 50 (2)
Height mm (in) 00 (11.8)
Height with fixings mm (in) 45 (1 .6)
Depth mm (in) 240 (9.5)
Weight kg (lb) 4. (9.5)
Mounting 2 x M5
Case IP 20
Storage Temperature °C -25…40
Transport Temperature °C -25…70
Operating Temperature °C 0…40 at rated data
40...50 with power derating
Relative humidity 95% (non-condensing)
Pollution IEC/EN
60664-1
Pollution degree 2
Site altitude m amsl to be defined
Max. Case Temperature °C 90
Max. Power Dissipation W 100
Mounting place In the control cabinet
Mounting position vertical
Distance between Controllers
(passive convection cooling)
mm (in) ≥ 5 (1.4) left (heat sink side)
≥ 5 (0.2) right
≥ 200 (8) top / bottom
Distance between Controllers (with fan
option EV01-E1400)
mm (in) ≥ 40 (1.6) left (heat sink side)
≥ 5 (0.2) right
≥ 200 (8) top / bottom
Distance between Controllers (cold plate
cooling)
mm (in) ≥ 0 (0) left/right
≥ 200 (8) top / bottom
Page 18/24 www.LinMot.com NTI AG / LinMot®

Preliminary E1400 Installation Guide
10 Power Supply Requirements
Motor Power Supply
Direct AC mains connection: /PE AC 400V (±10%) / 50-60Hz / TN System
/PE AC 480V (±10%) / 50-60Hz / TN System
Only 3-phase supply is supported!
DC Supply (for example 72VDC) for initial test setups can be supplied through
the 3-phase supply connector.
Use a circuit breaker C20 and conductor cross section of 2.5mm2 for mains
connections!
Signal Power Supply
The logic supply needs a regulated power supply of a nominal voltage of 24 VDC.
The voltage must be between 22 and 26 VDC.
Current consumption:
min. 0.5A (no load on the outputs)
typ. 1.5A (all 10 outputs “on” with 100mA load and /Break with no load)
max. 2.5A (all 10 outputs “on” with 100mA load and /Break with 1A load)
11 Regeneration of Power / Regeneration Resistor
There are two possibilities to deal with power regeneration:
Option A: DC Link coupling or additional Capacitors
Option B: Install a regeneration resistor to X1 (RR+ and RR-). The threshold
value of the voltage depends on the used motor voltage power supply.
The max. threshold value must not exceed 780 VDC.
Item Description Art. No.
Regeneration Resistor RR01-68/100 (68 Ohm, 100 W) 0150- 7
NTI AG / LinMot®www.LinMot.com Page 19/24

E1400 Installation Guide preliminary
12 Ordering Information
Item Description Art. Nr.
E1450-PL-QN POWERLINK Controller ( x400/28A) 0150-1791
E1450-PN-QN PROFINET Controller ( x400/28A) 0150-178
E1450-EC-QN ETHERCAT Controller ( x400/28A) 0150-1784
E1450-SC-QN SERCOS III Controller ( x400/28A) 0150-1785
E1450-IP-QN ETHERNET IP Controller ( x400/28A) 0150-1782
E14 0-DP-QN PROFIBUS-DP Controller ( x400/28A) 0150-1786
E1400-GP-QN GENERAL PURPOSE Controller ( x400/28A) 0150-1779
RS2 2 PC config. Cable
2.5m
For E1200 / E1400 0150-214
RR01-68/100 Regeneration resistor (68R, 100W, 1000V) 0150- 7
EV01-E1400 Fan Option for E1400 0150-5055
-phase line filter (tbd)
13 International Certifications
Certifications
Europe See chapter “14 Declaration of Conformity CE-Marking“
UL UL508C pending
Page 20/24 www.LinMot.com NTI AG / LinMot®
This manual suits for next models
7
Table of contents
Other NTI AG Controllers manuals
Popular Controllers manuals by other brands

Salus
Salus PCSol 300 Installation and operation manual

Schrack Technik
Schrack Technik BLR-CX user manual

PIETRO FIORENTINI
PIETRO FIORENTINI APERFLUX 101 Technical manual

CAME
CAME TOP-432EE quick start guide

G-Scale Graphics
G-Scale Graphics RailBoss 4 Basic Operation and installation manual

Toshiba
Toshiba 2000 user manual