NuAge Beauty OxyOasis User manual

Page | 1
©2014 NuAge Beauty, Inc. All Rights Reserved. 206485 NA.OO.10.1.0814.7.U

Page | 2
NuAge Beauty, Inc.
9220 James Avenue South, Minneapolis, MN 55431
Dear OxyOasisOwner:
Congratulations! We welcome you as a new owner of an OxyOasis System. Enclosed
you’ll find your OxyOasis Owner’s Manual. In it, you’ll find set-up and operating
instructions, facial protocols as well as service and troubleshooting tips. If you have
questions, please feel free to contact your Sales Representative or our Customer
Service Department.
We look forward to the opportunity of offering additional products and services to you.
Please contact us at 1 (877) 818-9988 or visit us at www.nuagebeauty.com.
In order to offer the highest quality products and services to our customers, we welcome
your feedback regarding your new OxyOasis System. Thank you for your business!
______________________________________________________________________
USA Distribution Contact NuAge Beauty, Inc. info@nuagebeauty.com
Tel 1 (952) 888-2088 I Toll free: 1 (877) 818-9988 I Fax: 1 (952) 888-8887
© 2014 Mpls. MN 55431 USA

Page | 3
TABLE OF CONTENTS
Page
Section 1 Introduction
1.1 Purpose of the Manual 4
1.2 Customer Service 4
1.3 Disclaimer 4
1.4 Copyright 4
Section 2 Safety
2.1 Precautionary Safeguards 6
2.2 Warnings ______________________________________________ 7
Section 3 Product Introduction
3.1 System Description 8
Section 4 Installation
4.1 Operational Components 9
4.2 Starting Up/Testing ______________________________________ 10
4.3 Connecting Tubing ______________________________________ 10
4.4 Assembling and Connecting the Micro Mist Air Spray Brush _______ 11
Section 5 Operation
5.1 Operating Your OxyOasis 12
5.2 Operating your Micro Mist Air Spray Brush _____________________ 12
5.3 Right/Wrong Ways to Use your OxyOasis System ________________ 14
Section 6 OxyOasis Protocols, featuring Oxygen Botanicals™
6.1 “Mini Blast” 15
6.2 “Super Blast” 16
6.3 “Secret Glow” 17
Section 7 Troubleshooting
7.1 Minor Troubleshooting Guide 18
Section 8 Maintenance
8.1 Cleaning 19
Section 9 Specification Information
9.1 General 21
Product Warranty 22

Page | 4
SECTION 1: INTRODUCTION
1.1 Purpose of the Manual
This manual explains how to correctly install, operate, and get the best performance
from your OxyOasis System. It will ensure you are utilizing the OxyOasis properly and
effectively. It also includes troubleshooting guidelines for mechanical and electrical
difficulties. This owner’s manual is organized as a quick reference guide. Any additional
updated or supplemental information for this reference guide may be distributed to you
as needed. Please read this owner's manual carefully before installing your device.
Keep your manual near your device for quick reference.
1.2 Customer Service
We welcome and appreciate your comments, questions, and suggestions in order to
continually offer the highest quality products, accessories, and services to our
customers. Our qualified professional teams are ready to assist you with a prompt
response to any question that you may have.
1.3 Disclaimer
While every attempt is made to ensure the accuracy and completeness of the
information in this document, some errors may exist. The distributor and manufacturer
do not accept responsibility of any kind for customer loss due to use of or reliance upon
this document.
The distributor and manufacturer reserve the right to make changes without notice in
the product described or contained herein in order to improve design and/or
performance. The distributor and manufacturer assume no responsibility or liability for
the use of the product, convey no license or title under any patent, copyright, or
trademark right to this product or process and make no representation or warranty that
this product is free from patent, copyright, or trademark right infringement, unless
otherwise specified. Applications that are described herein for the product are for
illustrative purposes only. The distributor and manufacturer make no representation or
warranty that such applications are suitable for the specified use without further testing
or modifications.
1.4 Copyright
This manual is protected by copyrights. All rights are reserved. No part of this
publication may be reproduced, stored in a retrieval system, or transmitted in any form
or by any means: electronic, mechanical, photocopying, recording, or otherwise without
the prior written permission from the author and publisher. All inquiries should be

Page | 5
addressed at the headquarters listed inside the front cover of this manual, along with a
date from a copy of the original purchase receipt of the OxyOasis System. No attempt
has been made to designate as trademarks or service marks all words or terms in which
proprietary rights might exist. The inclusion, exclusion, or definition of a word or term is
not intended to affect, or to express a judgment on, the validity or legal status of the
word or term as a trademark, service mark, or other proprietary term.

Page | 6
SECTION 2: SAFETY
2.1 Precautionary Safeguards
Use of Oxygen
Oxygen is not a flammable gas, but it accelerates the combustion of materials.
To avoid all risks of fire, the OxyOasis should be kept away from all flames,
incandescent sources and sources of heat (cigarettes), as well as any
combustible products such as oil, grease, solvents, aerosols, etc.
Do not use in an explosive atmosphere.
Avoid letting oxygen accumulate on an upholstered seat or other fabrics. In the
event that the concentrator is operating while not supplying oxygen to a patient,
position it so that the gas flow dilutes in the ambient air.
Place the device in a ventilated area free from smoke and atmospheric pollution,
at least 2 feet from any other object.
Use and Maintenance of the Device
Do not modify the OxyOasis System.
Use the cable provided and check that the electrical characteristics of the main
socket used match those indicated on the manufacturer’s plate on the rear panel
of the machine.
We recommend avoiding the use of extension cables or even adapters as they
are sources of sparks and therefore of fire.
The OxyOasis must only be used for oxygen air spray facial sessions.
Do not use in a specifically magnetic environment (MRI, etc.).
Do not carry out any facial session in areas exhibiting broken skin.
Do not use the micro-mist air spray brush with a humidifier bottle.
Do not use any essential oils with the humidifier bottle.
Do not use any flammable substance such as alcohol or acetone to prepare the
skin for facial.
Shut device off when not in use.
The manufacturer, assembler, installer or importer are not considered to be responsible
themselves for the consequences on the safety, reliability and characteristics of the
device unless:
The assembly, fitting, extensions, adjustments, modifications, or repairs have
been performed by persons authorized by the party in question.
The electrical installation of the corresponding premises complies with local
regulations.

Page | 7
The device is used in accordance with the instructions for use.
If the replacement parts used for the periodic servicing by an approved
technician do not comply with the manufacturer’s specification, the latter is
absolved from all responsibility in the event of electrical shock.
Only persons who have read and understood this entire
manual are authorized to use the OxyOasis.
2.2 Warnings
IMPORTANT SAFETY INFORMATION
This manual uses the following convention to highlight information relating to hazards
and precautions associated with your oxygen concentrator:
! DANGER –FIRE HAZARD, NO SMOKING
This device supplies high concentrations of oxygen which promotes rapid burning. Do
not allow smoking, open flames, or other ignition sources within 5 feet of this device or
its accessories. Oil, grease, or other petroleum products should NEVER be used on or
around the unit.
Do not use extension cords with this unit.
! WARNING –Risk of Electric Shock
Do not remove the cover or attempt to disassemble this product. Contact your
equipment provider if service is required.
Unplug the power cord from the AC wall outlet before cleaning.
Do not use if the power cord is damaged.
Note: The distributor and the manufacturer accept no responsibility for damages to
person or property resulting from improper use of the OxyOasis System.

Page | 8
SECTION 3: PRODUCT INTRODUCTION
The OxyOasis is an aesthetic oxygen concentrator. It provides a continuous flow of
oxygen-enriched air by separating the oxygen and nitrogen contained in ambient air.
This is not a medical device.
OxyOasis is a device that filters ambient air to provide the user with an uninterrupted
flow of enriched oxygen.
A compressor pulls in air and raises the air pressure in order to prepare the oxygen and
nitrogen for filtration. The compressed air is then delivered to one of two airtight
cylinders, where it is passed through a special, porous filter called zeolite. When
compressed air is passed through the zeolite, the nitrogen molecules chemically bond
to the zeolite while the oxygen flows through unimpeded to the user.
The machine enables a continuous flow of oxygen to the user by alternating the use of
each cylinder. When compressed air is directed to one cylinder, the air pressure in the
other cylinder is reduced to 0 PSI. The reduction in air pressure 'purges' the nitrogen
from the zeolite and prepares the cylinder for the next cycle. This process allows the
user to enjoy a steady flow of oxygen-enriched air.
3.1 System Description
The OxyOasis is easy to use and ergonomic. The single flow adjustment knob allows:
The device to be easily adjusted to the desired flow rate.
Technicians to limit flows to a specific range of flow rates with an internal locking
device.
Note: The performances described only relate to the use of the OxyOasis with the
accessories recommended by the manufacturer.

Page | 9
SECTION 4: INSTALLATION
4.1 Operational Components
1. Power Switch
2. Oxygen Outlet
3. Flow Meter with Control Knob
4. Air Filters
5. Place for Humidifier bottle (not to use
with the air spray brush)
6. LED Display
6.a Time Counting System
(CU= current use session time/total use)
6.b Power Disconnection
6.c Abnormal Voltage
6.d Power “ON” Indicator Light
7. Circuit Breaker Reset Button
8. Handle
1
7
6
3
6
5
2
4
8
6a
6b
6c
6d

Page | 10
4.2 Starting Up/Testing
1. Carefully unpack the concentrator and place upright on the floor.
2. Position the unit away from curtains or drapes, hot air registers and heaters. Be
certain to place the unit so all sides are at least 2 feet away from a wall or other
obstruction. Do not place the unit in a confined area.
CAUTION: Always operate the unit in an upright position.
3. Turn the unit so that the operating controls are within easy reach and the air
intake is not obstructed.
4. Remove the power cord completely from around the device (if wrapped around
the device).
5. Install the power cord into an appropriate power receptacle in the wall. Double
check to make sure the wall receptacle specifications match the power
requirements stated on the unit (110V or 220V).
6. Unpack the tubing found inside the concentrator shipping carton.
7. Air enters the oxygen concentrator through two air intake gross particle filters
located on the right side and underneath the oxygen concentrator. These filters
remove dust particles and other impurities from the air. Before you operate the
unit, make sure these filters are clean and positioned correctly (see Section 8
Maintenance for cleaning instructions).
8. Test the concentrator by pressing the power switch ON.
9. Next, turn the knob of the flow valve counter clockwise allowing oxygen to flow.
This should cause the steel ball inside the flow meter to “float” on the flow of
oxygen in accordance with the flow rate set. Check for oxygen flow at the output
fitting on the front side of the unit by placing glass of water under the nozzle. The
flow should disturb the surface of the water.
10.After the test, TURN THE UNIT POWER SWITCH “OFF”. The oxygen-enriched
airflow continues for approximately one (1) minute after the device is stopped.
11.If the unit fails to operate properly, refer to the troubleshooting section of this
manual for a list of probable causes and solutions.
4.3 Connecting tubing
1. Connect oxygen administration tubing to air outlet on OxyOasis.
2. Connect the other end of the tubing to dispensing method (air spray brush,
capsule, etc.). The tube between the customer and the OxyOasis should
be less than 5 feet long, in order to ensure that the oxygen flow rate
remains satisfactory.
3. Ensure that all of the parts are connected correctly so as to avoid leaks.

Page | 11
4.4 Assembling and Connecting the Micro Mist Air Spray Brush
Attention: never use your humidifier bottle with the use of the air spray brush
1. Attach tail piece to the base on the bottom of the spray brush.
2. Follow all steps from section 4.3 to connect oxygen administration tubing.
3. Connect the open tube end to the tail piece input fitting on the air spray
brush.
Serum/fluid cup
Tail piece
Spray brush base
Dropper
Oxygen & serum trigger
Trigger adjustment knob
Screw tail piece here

Page | 12
SECTION 5: OPERATION
5.1 Operating your OxyOasis
Follow the steps outlined in section 4.2 to test and connect the oxygen administration
tubing.
1. After initializing the oxygen concentrator, press
the power switch to turn ON the concentrator.
For best results, turn on the device 5 minutes
before you intend to use it.
2. Open the flow valve of the concentrator
by turning the flow meter knob counter-
clockwise. Adjust to 3.5 LPM for best results.
5.2 Operating your Micro Mist Air Spray Brush
Follow the steps outlined in section 4.4 to assemble the spray brush and connect the
oxygen administration tubing.
1. Fill the serum/fluid cup reservoir with liquid activators and desired serums (see
protocols for product suggestions). NEVER use essential oils for oxygen
spray.
2. Pull the trigger halfway for oxygen-enriched air only application.
3. Pull the trigger all the way for oxygen-enriched air plus product spray application.
4. Follow protocols for specifics on application and duration.

Page | 13
Holding Your Air Spray Brush
To hold the micro mist air spray brush effectively and ergonomically please
use the following steps:
•Firstly hold your hand flat with
your thumb facing upwards.
• Place the spray brush with
the nozzle sitting on your
middle finger and the end of
the spray brush cradled in
the groove of your thumb.
Keeping your hand relaxed:
• Fold your little, ring and
middle finger around the
base of the spray brush.
• Rest your index finger on the
side or base of the fluid cup.
• Leaving your thumb to rest on
the trigger enabling you to
control oxygen/serum flow.
Keeping your hand relaxed during
session reduces strain on your hand
and wrist.

Page | 14
Using the trigger on your Air Spray Brush
Your spray brush has 2 very simple actions you need to remember:
1. Using your thumb press down on the trigger to release the oxygen flow.
2. Keeping the trigger pressed down draw the trigger back, to release the serum from the fluid cup.
Please Note: You can regulate the amount of serum being sprayed by how far you pull the
trigger back (adjust from the back “trigger adjustment knob”)
Distance when spraying
1. When spraying large areas such as cheek or the forehead you must be 5 –6 cm (about 2 inches) away
from the surface of the skin.
2. When spraying smaller areas such as the eye, nose or upper lip you must be 1 cm (about ½ inch)
away from the surface of the skin.
5.3 Right/Wrong Ways to Use your OxyOasis System
Use of OxyOasis with Micro Mist Air Spray Brush
WRONG

Page | 15
SECTION 6: PROTOCOLS
“Mini Blast”
15 minutes
1. Skin has already been cleansed for facial
2. Prepare the micro mist air spray brush: fill up the fluid cup half-way with water based
products like activators or serums.
3. Turn on your OxyOasis and adjust flow meter to at least 3.5 LPM
4. Start by pulling the trigger halfway to release the gentle, adjustable flow of oxygen-enriched
air over the facial area with quick, back and forth motions: stay close to the skin at all times for best
results, work in small areas and spend more time on areas of concern
5. Pull trigger all the way back now to spray the solution over the area to soothe and refresh:
pull further away from skin and alternate with step 4 until the entire solution is released
6. Apply moisturizer
Page | 15

Page | 16
“super Blast”
45 minutes
1. Remove makeup first with Makeup Remover and rinse with a warm towel
2. Cleanse skin with a cleanser and rinse with a warm towel
3. Exfoliate skin
4. Turn on your OxyOasis and adjust flow meter to at least 3.5 LPM
5. Use the micro mist air brush without product in the fluid cup;
Work close to the skin in quick, back and forth motions
6. Apply mask
7. Prepare the micro mist air spray brush: fill the fluid cup halfway with water based activators or
serums
8. Start by pulling the trigger half way to release the gentle, adjustable flow of oxygen-enriched air
over the facial area with quick, back and forth motions: stay close to the skin at all time for best
results, work in small areas and spend more time on areas of concern
9. Pull trigger all the way back to spray the solution over the area to soothe and refresh: pull further
away from skin and alternate with step 10 until the entire solution is released
10. Apply small amount of Eye Cream
11. Apply moisturizer.
Page | 16

Page | 17
“secret glow”
60 minutes
1. Remove makeup first with Makeup Remover and rinse with a warm towel
2. Cleanse skin with small amount of cleanser and rinse with a warm towel
3. Exfoliate
4. Turn on your OxyOasis and adjust flow meter to at least 3.5 LPM
5. Take the micro mist air brush and use it without product in the fluid cup:
work close to the skin in quick, back and forth motions
6. Massage face, neck and décolleté
7. Apply masque
8. Prepare the micro mist air spray brush: fill up the fluid cup halfway with water based activator and
serums
9. Start by pulling the trigger half way to release the gentle, adjustable flow of
oxygen-enriched air over the facial area with quick, back and forth motions:
stay close to the skin at all time for best results, work in small areas
and spend more time on areas of concern
10. Pull trigger all the way back to spray the solution over the area to
soothe and refresh: pull further away from skin and alternate
with step 11 until the entire solution is released
11. Apply small amount of Eye Cream
12. Apply moisturizer
Page | 17

Page | 18
SECTION 7: TROUBLESHOOTING
7.1 Minor Troubleshooting Guide
Problem
Probable Cause
Solution
Unit does not operate
The power cord
is disconnected.
No power at
outlet.
Concentrator
circuit breaker
has tripped.
Connect power cord to wall outlet.
Check power source, fuses,
breakers, switches, etc.
Remove filter door on left side of the
concentrator and momentarily press
the circuit breaker reset button.
Push the circuit breaker button and if
no results, contact your provider.
Any other problems
Turn off your unit, stop the device and wait
for it to cool down. Check that the patient
circuit is not obstructed. Start up again. If
the device does not start, contact your
provider.
Air brush doesn’t
operate correctly or the
machine makes a weird
beeping noise
The air brush is not
properly connected
Make sure the hose is strongly
connected on both ends
DO NOT USE THE HUMIDIFIER
BOTTLE WITH THE AIR BRUSH
Air brush doesn’t
release serum when
trigger pulled all the
way back
Product used is not
liquid enough
Air brush is clogged
Back adjustment
knob is not loose
enough
Make sure you use only liquid
serums and no gel or thick viscosity
products in the fluid cup
Make sure you follow cleaning
process after each session
Make sure the back adjustment knob
is not tight so you can pull the trigger
all the way back
Try to shake a little the air brush as
you spray to help the serum diffuse if
necessary to get it started.

Page | 19
SECTION 8: MAINTENANCE
8.1 Cleaning
Air Filters
The air filters located on the right side and underneath the cabinet
should be cleaned at least once a week to keep your concentrator
running properly.
1. Turn off your concentrator and remove
the foam filter inserts from the right
side and underneath the cabinet.
2. Wash the filters in warm water and
dishwashing soap, rinse thoroughly,
and dry with a towel. The filter should
be completely dry before reinstalling.
! CAUTION –Do not operate the concentrator without the filters installed or while
either filter is damp.
Oxygen Tubing, Accessories
1. Clean and/or replace your oxygen tubing and accessories as needed.
2. The micro mist air spray brush must be cleaned for each new customer.
Exterior Cabinet
You may clean the exterior of the concentrator cabinet as needed using a damp
cloth or sponge with a mild household cleaner and wipe dry.
! WARNING –Disconnect the power cord from the electrical outlet before cleaning.
! WARNING –Do not apply liquid directly to the cabinet or use any petroleum-
based solvents or cleaners.

Page | 20
Micro mist air spray brush cleaning instructions
Using a small bristle brush and the isopropyl alcohol, clean any residue from the
color cup. Once this is done you should back flush the airbrush by filling the product cup
with isopropyl alcohol, pull the trigger with your finger covering the air tip, as pictured
below in pic 1.
Pic 1
It is essential you clean the spray brush after every treatment.
Please follow the instructions below to best clean your spray brush.
• Using tap warm to hot water to rinse cup and lid thoroughly.
• Make sure you rub the inside of the cup and thoroughly remove all traces of serum.
• Fill the cup with water, hold your finger over the tip of the infuser, press down and pull
back on the trigger. This will create back flow causing the water in the cup to bubble.
• Let the liquid bubble for a few seconds then release your finger from the tip of the
serum cup. Keeping the trigger pressed down and pulled back spray water through.
• Repeat this process 3-4 times.
• Dry the cup and lid and make sure you have sprayed all water out.
• On the final rinse use a sterilizing solution or alcohol in place of water.
• Using a square alcohol swab scrunch a corner to create a point.
• Insert swab into the end of the infuser tip and wipe the inside.
Points to remember
• Never insert a cotton bud or anything stiff into the tip of the infuser as this will bend the
fine needle slightly protruding and prevent the infuser from spraying effectively.
• Use a sterilizing solution to complete the cleaning process, especially if you have
treated an open wound or infected pustule.
Table of contents
Other NuAge Beauty Personal Care Product manuals