4
Before use operators shall be provided with information, instruction and training for the use of the machine and the
substances for which it is to be used, including the safe method of disposing of material collected.
The dust container has to be emptied not only when necessary, but also after each time it is used.
This vacuum cleaner has a lamp that will ash when air velocity drops below a preset level, which indicates that the
bag must be changed.
All lters including the bag must be undamaged and in correct position before this machine can be used safely.
Do not pick up glowing embers or dust or any other ignition hazard
Do not use the power cable as a method of moving the machine.
WARNING:
1. This machine must only be operated by suitably trained and authorised personnel.
2. This machine or its accessories must not be modied.
3. The machine must not be stored or used in a wet environment.
4. Do not allow the dust collection bag to become so full as to reduce the effective pick-up of the
vacuum. (Lamp will ash at preset air velocity levels).
5. Only use the dust collection bag once.
6. This machine must only be repaired by suitably trained and authorised personnel.
7. Only use genuine Numatic International Ltd spare parts, for repairs.
8. This machine must not be installed as a xed extraction system or run unattended.
Do not re-use the essential lter element after removal out of the machine.
Do not pick up glowing dust or other ignition hazards.
Operators should observe any safety regulations appropriate to materials being handled.
This machine is for dry use only.
PREPARATION FOR USE
Unpack and identify each item of equipment from the delivery note.
Check that the details given match the information on the “rating plate” mounted on the head assembly.
Installation / Removal / Disposal of the dust bag.
The dust bag holding the dust and debris must be removed and renewed by authorised personnel only, wearing
appropriate personnel protective equipment, in a specied de-contamination area.
Never operate without the full ltration system in place.
Process of disposal:
Disconnect the hose, t the dust cap on the hose ange, un-clip the bottom two toggle clamps.
(Upper two toggle clamps have split pins that should not be removed by un-authorised personnel).
Remove the cloth lter in the drum.
Remove the dust bag from the hose ange inside the drum and seal the dust bag hole.
Place the dust bag inside an impervious plastic bag and seal the bag.
Dispose of the plastic bag, depending on contamination, in an appropriate manner.
Fit a new dust bag over the hose ange inside the drum assembly.
Fit the cloth lter and the head, plus interceptor assembly, re-applying the two Toggle clamps.
Important User Information
Only use accessories approved for Type ESD use.
The use of other accessories may cause electrostatic discharges.
Ensure that the tted plug and power socket meets national regulations for EPAs and ESD.
The use of other accessories may cause an explosion hazard.
Hepa Anti Static