Page 1
MODEL QTNLEDB
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer at the address
or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service
panel and lock the service disconnecting means to prevent
power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a
prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a
qualified person(s) in accordance with all applicable codes
and standards, including fire-rated construction codes and
standards.
4. Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equipment
to prevent backdrafting. Follow the heating equipment
manufacturer’s guideline and safety standards such as those
published by the National Fire Protection Association (NFPA),
and the American Society for Heating, Refrigeration and
Air Conditioning Engineers (ASHRAE), and the local code
authorities.
5. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. Acceptable for use over a tub or shower when connected to
a GFCI (Ground Fault Circuit Interrupter) - protected branch
circuit.
8. This unit must be grounded.
CAUTION
!
1. For general ventilating use only. Do not use to exhaust
hazardous or explosive materials and vapors.
2. This product is designed for installation in ceilings up to a
12/12 pitch (45 degree angle). Duct connector must point up.
DO NOT MOUNT THIS PRODUCT IN A WALL.
3. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power
unit.
4. The LED light source is designed for this specific application
and can overheat if serviced by untrained personnel. If any
servicing is required, the product should be returned to an
authorized service facility for examination or repair.
5. Please read specification label on product for further
information and requirements.
READ AND SAVE THESE INSTRUCTIONS
CLEANING & MAINTENANCE
For quiet and efficient operation, long life, and attractive
appearance - lower or remove grille and vacuum interior of unit
with the dusting brush attachment.
To clean the LED plate:
1. Remove grille from
ceiling and unplug
wiring from housing.
2. Remove lens.
3. Remove three (3)
screws from retention
ring.
4. Remove LED plate and
wash plate with a mild
detergent solution.
DO NOT USE
ABRASIVE
CLOTH, STEEL WOOL
PADS, SCOURING
POWDERS, CLEANING
SPRAYS OR
SOLVENTS.
5. Re-assemble grille
assembly and re-install
to fan housing.
The motor is permanently lubricated and never needs oiling. If the
motor bearings are making excessive or unusual noises, replace
the blower assembly (includes motor and impeller).
OPERATION
The fan, light, and night light can be operated separately. Use a
3-function wall control. Do not use a dimmer switch to operate
the light. See “Connect Wiring” for details. Use of speed controls
other than the NuTone Models 78V and 78W may cause a motor
humming noise.
Installer: Leave this manual with
the homeowner.
MODEL QTNLEDB
FAN / LIGHT / LED NIGHT LIGHT
LENS
SCREWS RETENTION
RING
LED
PLATE
GRILLE
Page 2
MODEL QTNLEDB
TYPICAL INSTALLATIONS
Housing mounted to I-joists.
Housing mounted anywhere be-
tween trusses using hanger bars.
PLAN THE INSTALLATION
Housing mounted anywhere be-
tween I-joists using hanger bars.
Housing mounted to joists. Housing mounted anywhere be-
tween joists using hanger bars.
Housing mounted anywhere between
trusses using hanger bars.
Cooking
Equipment
Floor
COOKING AREA
Do not install above or
inside this area.
45
o
45
o
NOT FOR USE IN
A COOKING AREA.
The ducting from this fan to the outside of the building has
a strong effect on the air flow, noise and energy use of the
fan. Use the shortest, straightest duct routing possible for
best performance, and avoid installing the fan with smaller
ducts than recommended. Insulation around the ducts can
reduce energy loss and inhibit mold growth. Fans installed
with existing ducts may not achieve their rated airflow.
6-inch round rigid metal duct is recommended for best
performance.
Use a roof cap or wall cap that has a built-in damper to
reduce backdrafts.
Plan to supply the unit with proper line voltage and
appropriate power cable.
INSTALL HOUSING & DUCT
1a.Mount
housing
to joist or
I-joist.
Use a pliers to
bend housing
TABS out
to 900. Hold
housing in
place so that
the housing
tabs contact
the bottom
of the joist.
The housing
mounts with
four (4) screws
or nails. Screw
or nail housing
to joist through
lowest holes in
each mounting
flange, then
through
highest holes.
SPACER
(use for mounting to I-Joist)
I-JOIST
NOTE: Mounting to I-JOIST (shown) requires use of
SPACERS (included) between the highest hole of
each mounting flange and the I-joist.
OR
*Purchase
separately.
INSULATION*
(Place around and
over Fan Housing.)
ROOF CAP*
(with built-in
damper)
FAN
HOUSING
POWER
CABLE*
ROUND
DUCT*
ROUND
ELBOWS*
Seal gaps
around
Housing.
Seal duct
joints with
tape.
OR
Keep duct
runs short.
WALL CAP*
(with built-in
damper)
TABS
Page 3
MODEL QTNLEDB
4. Connect electrical wiring.
Run 120 VAC house wiring to installation location. Use
proper UL approved connector to secure house wiring to
wiring plate. Connect wires as shown in wiring diagrams.
CONNECT WIRING
2. Attach
damper/duct
connector.
Snap damper /
duct connector
onto housing.
Make sure
connector is flush
with top of housing
and damper flap
falls closed.
3. Install
6-inch or
4-inch round
ductwork.
Connect 6-inch
or 4-inch round
ductwork to
damper/ duct
connector or
reducer. Run
ductwork to a roof
cap or wall cap.
Tape all ductwork
connections to make them secure and air tight.
1b.Mount housing anywhere between
trusses, joists, or I-joists using hanger
bars.
Sliding hanger bars are provided to allow for accurate
positioning of housing anywhere between framing.They can
be used on all types of framing (I-joist, standard joist, and
truss construction) and span up to 24”.
Attach the MOUNTING CHANNELS to the housing using
the SCREWS supplied. Make sureTABS face “up” as shown.
Use the set of channel mounting holes (marked “STD”) to
mount the housing flush with the bottom of the drywall. Use
the other set of holes (not marked) to mount the housing
flush with the top of the drywall.
HANGER
BAR (4)
SCREWS (4)
TAB
Extend HANGER BARS to the width of the framing.
Hold ventilator in place with the hanger bar tabs wrapping
around the BOTTOM EDGE OF THE FRAMING.
NAIL ventilator to framing or fasten with screws (not provided)
through HOLES near nails.
*To ensure a noise-free mount: Secure hanger bars together
with SCREWS or use a pliers to crimp mounting channels
tightly around hanger bars.
HOLE FOR OPTIONAL
SCREW MOUNTING (4)
STD
MOUNTING
CHANNEL (2)
NAIL (4)
BOTTOM EDGE
OF FRAMING
*SCREW (2)
Page 4
MODEL QTNLEDB
SERVICE PARTS
99045485B
KEY NO. PART NO. DESCRIPTION
1 SQTHB1 HANGER BAR KIT
2 475 DUCT REDUCER 6” TO 4”
3 97018562 DUCT CONNECTOR - 6”
4 99111293 SPACER (2 REQ’D)
5 97016466 HOUSING
6 98010102 WIRING PLATE
7 99170245 SCREW, #8-18 X .375
8 97018552 WIRE PANEL/HARNESS ASSEMBLY
9 97020045 CONTROL ASSEMBLY
10 97020046 SERVICE ASSEMBLY, BLOWER
(INCLUDES KEY NO. 11)
11 99420665 THUMBSCREW, #8-18 X .375
12 99140199 GRILLE SPRING (2 REQ’D)
13 97018561 GRILLE ASSEMBLY
14 99271381 BULB, GU24, 18W FLUORESCENT (2 REQ’D)
15 99111532 RING
16 99111529 LENS
* Not shown assembled.
Order service parts by “Part No.” - not by “Key No.”
INSTALL GRILLE
5. Finish ceiling.
Install ceiling material. Cut out around housing.
7. Attach grille to
housing.
Squeeze grille springs
and insert them into tabs
on each side of housing.
9. Remove light
lens.
Carefully insert a small
flat-blade screwdriver
between grille and lens.
Pry lens out.
8. Push grille
against ceiling.
SERVICE NOTE
To remove Blower
Assembly: Unplug motor.
Remove thumbscrew (11)
from motor plate flange.
Find the single TAB on the
motor plate (located next
to the receptacle). Push
up near motor plate tab
while pushing out on side
of housing. Or insert a
straight-blade screwdriver
into slot in housing (next to
tab) and twist screwdriver.
10. Install light bulbs.
Purchase (2) 18W (max.),
type GU24 fluorescent
lamps with M.O.L.
(maximum overall length)
of 3.9” (100mm) as
illustrated below.
Insert lamps and bulb into
their sockets. Replace lens.
3.9" (100mm) M.O.L.
6. Plug in wiring.
Plug wiring into proper receptacles.
DIAGONAL LED PLATE OPTION
To rotate LED plate to
diagonal position:
1. Remove grille from ceiling and
unplug wiring from housing.
2. Remove lens.
3. Remove three (3) screws from
retention ring.
4. Remove LED plate and rotate
plate clockwise to diagonal
position.
5. Re-assemble grille assembly
and re-install to fan housing.
LENS
SCREWS RETENTION
RING
LED
PLATE
GRILLE
Discover other home shop on our website.

Other NuTone Fan manuals

NuTone 758NT User manual

NuTone

NuTone 758NT User manual

NuTone 769RL User manual

NuTone

NuTone 769RL User manual

NuTone PFCH42 Series User manual

NuTone

NuTone PFCH42 Series User manual

NuTone RDF2 User manual

NuTone

NuTone RDF2 User manual

NuTone PFC-48 User manual

NuTone

NuTone PFC-48 User manual

NuTone QT150 User manual

NuTone

NuTone QT150 User manual

NuTone GF900N User manual

NuTone

NuTone GF900N User manual

NuTone 768CHNT Owner's manual

NuTone

NuTone 768CHNT Owner's manual

NuTone PH416 User manual

NuTone

NuTone PH416 User manual

NuTone ROOMSIDE AERN110SLW Installation guide

NuTone

NuTone ROOMSIDE AERN110SLW Installation guide

NuTone F305C User manual

NuTone

NuTone F305C User manual

NuTone 754RBNT User manual

NuTone

NuTone 754RBNT User manual

NuTone QTXE080 User manual

NuTone

NuTone QTXE080 User manual

NuTone 349BR User manual

NuTone

NuTone 349BR User manual

NuTone QTXEN080FLT User manual

NuTone

NuTone QTXEN080FLT User manual

NuTone ROOMSIDE Series User manual

NuTone

NuTone ROOMSIDE Series User manual

NuTone ARP6 User manual

NuTone

NuTone ARP6 User manual

NuTone ULTRA Pro RB80L User manual

NuTone

NuTone ULTRA Pro RB80L User manual

NuTone 770F User manual

NuTone

NuTone 770F User manual

NuTone ILF-120 Service manual

NuTone

NuTone ILF-120 Service manual

NuTone 765hl User manual

NuTone

NuTone 765hl User manual

NuTone 671R User manual

NuTone

NuTone 671R User manual

NuTone XN80L User manual

NuTone

NuTone XN80L User manual

NuTone ZB110HL User manual

NuTone

NuTone ZB110HL User manual

Popular Fan manuals by other brands

ERA TEVIN CV Service instruction

ERA

ERA TEVIN CV Service instruction

Master DF 48 P User and Maintenance Book

Master

Master DF 48 P User and Maintenance Book

ETL 40829 manual

ETL

ETL 40829 manual

Overland Storage NEO Series Assembly instructions

Overland Storage

Overland Storage NEO Series Assembly instructions

FläktGroup EQAZ-04 Installation instruction

FläktGroup

FläktGroup EQAZ-04 Installation instruction

Siegenia AEROMAT midi Installation and operating instructions

Siegenia

Siegenia AEROMAT midi Installation and operating instructions

Lincoln Electric SF2400 STATIONARY FAN IM622 Operator's manual

Lincoln Electric

Lincoln Electric SF2400 STATIONARY FAN IM622 Operator's manual

TJERNLUND HSJ manual

TJERNLUND

TJERNLUND HSJ manual

Litex E-GD52ABZ5C installation guide

Litex

Litex E-GD52ABZ5C installation guide

Helios GigaBox GBW EC Series Installation and operating instructions

Helios

Helios GigaBox GBW EC Series Installation and operating instructions

Exhausto VEX310T Assembly and installation

Exhausto

Exhausto VEX310T Assembly and installation

MiniSun 19500 manual

MiniSun

MiniSun 19500 manual

Power Breezer PB20-C-00-B-CE/EMI user manual

Power Breezer

Power Breezer PB20-C-00-B-CE/EMI user manual

CANVAC Q AIR CPF4360S user manual

CANVAC

CANVAC Q AIR CPF4360S user manual

Olimpia splendid SITALI CXRA 120 Instructions for installation, use and maintenance manual

Olimpia splendid

Olimpia splendid SITALI CXRA 120 Instructions for installation, use and maintenance manual

Vannus VC3-3B/52 LED instruction manual

Vannus

Vannus VC3-3B/52 LED instruction manual

Modern Forms Mykonos 5 installation instructions

Modern Forms

Modern Forms Mykonos 5 installation instructions

Hunter 23348 Installation and operation manual

Hunter

Hunter 23348 Installation and operation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.