manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. nvent
  6. •
  7. Power Distribution Unit
  8. •
  9. nvent Schroff RackPower RP 2325 Quick start guide

nvent Schroff RackPower RP 2325 Quick start guide

Other nvent Power Distribution Unit manuals

nvent SCHROFF Rack Safety Plus User manual

nvent

nvent SCHROFF Rack Safety Plus User manual

nvent SCHROFF Rack Safety Plus User manual

nvent

nvent SCHROFF Rack Safety Plus User manual

nvent SCHROFF 21270 Series User manual

nvent

nvent SCHROFF 21270 Series User manual

Popular Power Distribution Unit manuals by other brands

Lightcorp Nik installation instructions

Lightcorp

Lightcorp Nik installation instructions

hager SP 015 User instructions

hager

hager SP 015 User instructions

Pakedge PowerPak 9 user guide

Pakedge

Pakedge PowerPak 9 user guide

Pts 9042 Series installation guide

Pts

Pts 9042 Series installation guide

Shure WA405 user guide

Shure

Shure WA405 user guide

CORNING CCH 4U quick start guide

CORNING

CORNING CCH 4U quick start guide

Panamax M4LT-EX datasheet

Panamax

Panamax M4LT-EX datasheet

PANCONNECT FLAT 3M Assembly instruction

PANCONNECT

PANCONNECT FLAT 3M Assembly instruction

Raytheon 138-118 manual

Raytheon

Raytheon 138-118 manual

StarTech.com RKPW161915 Spec sheet

StarTech.com

StarTech.com RKPW161915 Spec sheet

D&R ELECTRONICS PDU-6SS user manual

D&R ELECTRONICS

D&R ELECTRONICS PDU-6SS user manual

Botex PSA 322-6 DL quick start guide

Botex

Botex PSA 322-6 DL quick start guide

GE QuiXtra 4000 Assembly and mounting instructions

GE

GE QuiXtra 4000 Assembly and mounting instructions

Vertiv Knürr DI-Strip Rack PDU manual

Vertiv

Vertiv Knürr DI-Strip Rack PDU manual

ABB PSBS0065 Instruction handbook

ABB

ABB PSBS0065 Instruction handbook

Baumuller BFN 3-1-0007-001 Instruction handbook

Baumuller

Baumuller BFN 3-1-0007-001 Instruction handbook

Eaton StructuredWiringSolutions ESWT41600 Instruction leaflet

Eaton

Eaton StructuredWiringSolutions ESWT41600 Instruction leaflet

GE GEK-45404F instructions

GE

GE GEK-45404F instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

UNLESS NOTED, DIMENSIONS ARE IN
MILLIMETERS & TOLERANCES ARE:
ENGINEER:
SIZE:
REV.
DRAWN BY:
X.
X.X
X.XX
X.X
X.XX
1 MM
0.5 MM
0.20 MM
0.3 MM
0.10 MM
X
1
X.X
0.5
INTERPRET PER ASME Y14.5M-1994
BRACKETED DIMENSIONS ARE IN
INCHES FOR REFERENCE ONLY
THRID ANGLE PROJECTION
LRF
APPROVED BY:
PART NO:
TITLE:
PROJECT:
A3
THIS DRAWING AND SPECIFICATIONS HEREIN ARE THE PROPERTY OF CIS
GLOBAL AND SHALL NOT BE COPIED, REPRODUCED OR USED IN WHOLE OR IN
PART, AS THE BASIS FOR THE MANUFACTURE OR SALE OF ITEMS WITHOUT
WRITTEN PERMISSION FROM CIS GLOBAL. THIS DRAWING IS BASED UPON
LATEST AVAILABLE INFORMATION AND IS SUBJECT TO CHANGE WITHOUT NOTICE
E1
2022/05/13
RP2325WXYZ_DA
Rack
Power
SHEET
1 OF 3
SCALE:N/A
ECN/ECO
REV.
DESCRIPTION
DATE
APPROVED
REVISIONS
E1
INITIAL DRAFT REVIEW
2022/05/13
LRF
$ $
% %
& &
' '
( (
) )
* *
+ +
- -
. .
/ /
0 0
































Advantage Series
Metered Switched
(DEFAULT) TOP FEED = 0
BOTTOM FEED = 2
(DEFAULT) 3m [10'] = 0
(DEFAULT) BLACK = 0
RED = R
GREEN = G
MODEL IS SHOWN IN DEFAULT CONFIGURATION. FOR
OPTIONAL CONFIGURATIONS, USE ITEM IDENTIFIER
CODE IN PLACE OF EACH ASTERISK. ORDERABLE
BASED ON FORMAT: RP2325* * * *
DO NOT INCLUDE TRAILING ZEROS IN * * * * SUFFIX
OPTIONS LISTED ON THIS ROW ARE NON STANDARD,
CONTACT SALES FOR ADDITIONAL INFORMATION
RP 2325
0.5m [1.6'] = A
1.5m [4.9'] = B
2.5m [8.2'] = C
1.2m [4'] = G
1.8m [6'] = F
(DEFAULT) 332P6(IP44)=0 BLUE = B
WHITE = W
YELLOW = Y
IDENTIFICATION TABLE
INPUT PLUG CHASSIS COLOR CORD OPTION ORIEN
*
TATION
ORANGE = A
1m [3.2'] = 1
2m [6.6'] = 2
* * *
NOTES :
NATIONAL, STATE
1. INSTALLATION SHALL COMPLY WITH ALL APPLICABLE
AND LOCAL CODES.
2.
3.
PRIMARY DIMENSIONS ARE IN MILLIMETERS. SECONDARY DIMENSIONS
ARE IN [INCHES]
UNIVERSAL MOUNTING BRACKET IS AN ALTERNATIVE MOUNTING
METHOD TO THE TOOLLESS MOUNT FOR 3RD PARTY ENCLOSURES.
BRACKET IS PROVIDED WITH THE UNIT.
4. DETAILED INSTALLATION INSTRUCTIONS CAN BE FOUND IN THE QUICK
START GUIDE
5. CONNECT EXTERNAL EARTH GROUND TO THE 10-32 SIZE THREADED NUT
6.
7.
SEE PRODUCT DOCUMENTATION FOR FURTHER INFORMATION
INPUT PLUG CONFIGURATION (SEE IDENTIFICATION TABLE) FOR DUAL-
RATED UNITS, NEMA PLUGS ARE NAM RATED ONLY AND CAPTIVE AUS/NZ
PLUGS ARE EMEA RATED ONLY
MAX OPERATING
ELEVATION, ABOVE MSL
HUMIDITY
(OPERATING/STORAGE)
METERING ACCURACY
5-90% RH / 5-95% RH;
NON-CONDENSING
VOLTAGE(V), CURRENT(A), APPARENT
POWER(kVA), REAL POWER(kW),
POWER FACTOR, ENERGY(kWh)
3000M(9840FT)
RoHS COMPLIANT
COMPLIANCE
SAFETY&ENVIRONMENTAL
METERING ATTRIBUTES
FEATURES
INPUT POWER CORD:
METERED COMPONENTS
REMOTE OUTLET SWITCHING
ENVIRONMENTAL CONDITIONS
OPERATING TEMPERATURE
STORAGE TEMPERATURE
INPUT PLUG:
RATED POWER:
INPUT PHASE:
BREAKER QTY & TYPE:
INPUT CURRENT:
INPUT VOLTAGE:
OUTLET QTY & TYPE:
ORIENTATION:
UNIT TYPE:
TECHNICAL SPECIFICATIONS
MONITORED SWITCHED
VERTICAL, 0U FULL
(20)C13, (4)C19
200-240VAC
32A
(2) 16AMP, SINGLE-POLE
SINGLE-PHASE
7.4kVA
SEE NOTE 7
SEE IDENTIFICATION TABLE
+-1% TO ISO/ IEC 62052-21
INPUT(PHASE), CIRCUIT BREAKERS
YES
-5 TO 60 C (23 TO 140 F)
-20 TO 60 C (-4 TO 140 F)
FRONT VIEW BOTTOM VIEW
SIDE VIEW
1000
10
100
Reset
Senso
Port 2
r
RackPower
100
10
Senso
Port 1
r
INPUT CORD
LENGTH SEE
IDENTIFICATION
TABLE
LJB
Hanson
2022/10/08
LRF
E2
ECN-2210-0226
REVISE METER ACCURACY AND ATTRIBUTES CONTENT
2022/10/08
2022/10/08
UNLESS NOTED, DIMENSIONS ARE IN
MILLIMETERS & TOLERANCES ARE:
ENGINEER:
SIZE:
REV.
DRAWN BY:
X.
X.X
X.XX
X.X
X.XX
1 MM
0.5 MM
0.20 MM
0.3 MM
0.10 MM
X
1
X.X
0.5
INTERPRET PER ASME Y14.5M-1994
BRACKETED DIMENSIONS ARE IN
INCHES FOR REFERENCE ONLY
THRID ANGLE PROJECTION
LRF
APPROVED BY:
PART NO:
TITLE:
PROJECT:
A3
THIS DRAWING AND SPECIFICATIONS HEREIN ARE THE PROPERTY OF CIS
GLOBAL AND SHALL NOT BE COPIED, REPRODUCED OR USED IN WHOLE OR IN
PART, AS THE BASIS FOR THE MANUFACTURE OR SALE OF ITEMS WITHOUT
WRITTEN PERMISSION FROM CIS GLOBAL. THIS DRAWING IS BASED UPON
LATEST AVAILABLE INFORMATION AND IS SUBJECT TO CHANGE WITHOUT NOTICE
E1
2022/05/13
RP2325WXYZ_DA
Rack
Power
SHEET
2 OF 3
SCALE:N/A
ECN/ECO
REV.
DESCRIPTION
DATE
APPROVED
REVISIONS
E1
INITIAL DRAFT REVIEW
2022/05/13
LRF
$ $
% %
& &
' '
( (
) )
* *
+ +
- -
. .
/ /
0 0
































NOTES
:
1.
INSTALLATION SHALL COMPLY WITH ALL APPLICABLE NATIONAL,
STATE AND LOCAL CODES.
2.
SEE PRODUCT DOCUMENTATION FOR FURTHER INFORMATION
RECEPTA
STANDARD
CLES
INPUT PLUG
(DEFAULT)
RECEPTACLE RECEPTACLE
OPTIONAL
RECEPTACLE
EXTERNAL GROUND
IEC 60309, 2P 3W, 6H
IP44 (SPLASHPROOF)
32A, 200-250V MAX RATED
INPUT

NMC SHOWN IN DEFAULT
ORIENTATION
16 AMP, SINGLE-POLE ELECTRO
MECHANICAL SWITCH / BREAKER
(2) PLACES
IEC 60320/C19
16A, 250V MAX
RATED OUTPUT
IEC 60320/C13
10A, 250V MAX
RATED OUTPUT
IEC 60320/C19
16A, 250V MAX
RATED OUTPUT
IEC 60320/C13
10A, 250V MAX
RATED OUTPUT
2.2
.09
Ø
10.4
.41
2.0
.08
BUTTON MOUNTING SCREW
(INCLUDED)
18.4 [.60]
02817,1*%87721
$"$$"$
%-(- $'&-(-
$
!--'#&%--!"$ &"!-$!%$-






$ 
$ $+-!&)"$-" '!&"!%-
$$
'-"&%)#-"$-"$!&&"!-!%-
$$$
-$ -
%%+-!-$ -
,!($"! !& "!-
'$&+-$ -
$'&-$$-$ -
 $$"$



 





# $$
"$-$'!!+--%!-
! $$
'##"$&%-*&$!-%!%"$%--#$#$%-
1000
10
100
Reset
Senso
Port 2
r
RackPower
100
10
Senso
Port 1
r
Advantage Series
Metered Switched LJB
Hanson
2022/10/08
LRF
E2
ECN-2210-0226
REVISE METER ACCURACY AND ATTRIBUTES CONTENT
2022/10/08
2022/10/08
UNLESS NOTED, DIMENSIONS ARE IN
MILLIMETERS & TOLERANCES ARE:
ENGINEER:
SIZE:
REV.
DRAWN BY:
X.
X.X
X.XX
X.X
X.XX
1 MM
0.5 MM
0.20 MM
0.3 MM
0.10 MM
X
1
X.X
0.5
INTERPRET PER ASME Y14.5M-1994
BRACKETED DIMENSIONS ARE IN
INCHES FOR REFERENCE ONLY
THRID ANGLE PROJECTION
LRF
APPROVED BY:
PART NO:
TITLE:
PROJECT:
A3
THIS DRAWING AND SPECIFICATIONS HEREIN ARE THE PROPERTY OF CIS
GLOBAL AND SHALL NOT BE COPIED, REPRODUCED OR USED IN WHOLE OR IN
PART, AS THE BASIS FOR THE MANUFACTURE OR SALE OF ITEMS WITHOUT
WRITTEN PERMISSION FROM CIS GLOBAL. THIS DRAWING IS BASED UPON
LATEST AVAILABLE INFORMATION AND IS SUBJECT TO CHANGE WITHOUT NOTICE
E1
2022/05/13
RP2325WXYZ_DA
Rack
Power
SHEET
3 OF 3
SCALE:N/A
ECN/ECO
REV.
DESCRIPTION
DATE
APPROVED
REVISIONS
E1
INITIAL DRAFT REVIEW
2022/05/13
LRF
$ $
% %
& &
' '
( (
) )
* *
+ +
- -
. .
/ /
0 0
































NOTES
:
INSTALLATION SHALL COMPLY WITH ALL APPLICABLE NATIONAL,
1.
STATE AND LOCAL CODES.
SEE PRODUCT DOCUMENTATION FOR FURTHER INFORMATION
2.
THIS DRAWING DEPICTS THE POWER SYSTEM CONNECTIONS AND
3.
IS NOT REPRESENTATIVE OF THE PHYSICAL LAYOUT. PLEASE
REFER TO MECHANICAL DRAWINGS FOR PHYSICAL LAYOUT.
COMPLIANCE LABEL
SKU #: RP2325WXYZ
Model #: EP21032-0013
INPUT:200-240VAC, 1PHASE, 50/60Hz, 32A
OUTPUT:C13; 200-240VAC, 10A per outlet
C19; 200-240VAC, 16A per outlet
32A Total
MAC0 Address:XX-XX-XX-XX-XX-XX
MAC1 Address:XX-XX-XX-XX-XX-XX
RackPower Distribution Unit
Metered Switched
Mfr.Name:XXXXXXXXXXXXXXXXXXXXXXXXX
Made In XXXXX SKU#
:
R P2325WX Y Z
Serial Number
XXXXXXXX
XXXXX
PRODUCT CODE
INTERNAL WIRING SCHEMETIC
NOTES:
1. INTERNAL WIRING:
WIRE TYPE:
LINE 1/R/X COLOR:
EARTH GROUND COLOR:
NEUTRAL WIRE COLOR:
UL AWM 1015, 12 & 18AWG
BROWN
GREEN/YELLOW STRIPE
BLUE
2. FOR FINISHED GOOD PART NUMBER SEE IDENTIFICATION
Advantage Series
Metered Switched
nVent Electric plc
1665 Utica Ave, Suite 700
Minneapolis, MN 55416
LJB
Hanson
2022/10/08
LRF
E2
ECN-2210-0226
REVISE METER ACCURACY AND ATTRIBUTES CONTENT
2022/10/08
2022/10/08