O.Y.L. Technology AX1 LED User manual

Security
&
Home Automation System
AXI LED
USER MANUAL
(REV. 1.0)

AX1 LED User Manual Rev 1.0

AX1 LED User Manual Rev 1.0
CONTENTS
PREFACE
FEATURES
LED KEYPAD OUTLOOK
1.0 LIGHT INDICATION
CHAPTER 1: ALARM SYSTEM CONTROL
1.0 USING LED KEYPAD
1.0.1 ARMING
1.0.1.1 QUICK ARMING
1.0.2 DISARMING
1.0.2.1 IN ARMED MODE
1.0.2.2 IN ALARM MODE
1.0.3 ALARM REPORT
1.0.4 CLEAR ALARM MEMORY
1.0.5 BYPASSING ZONE
1.0.5.1 QUICK BYPASSING ZONE
1.1 ARM/DISARM USING TELEPHONE
1.1.1 ARM/DISARM WITH VOICE ACTIVE
1.1.2 ARM/DISARM WITH BEEPER
CHAPTER 2: HOME AUTOMATION CONTROL
2.0 INTRODUCTION
2.1 HOME AUTOMATION CONTROL USING LED KEYPAD
1
2
4
6
7
7
7
7
8
8
8
9
9
10
10
11
11
12
13
13
14

AX1 LED User Manual Rev 1.0
2.2 HOME AUTOMATION CONTROL USING TELEPHONE
2.2.1 WITH VOICE ACTIVE
2.2.2 WITH BEEPER
CHAPTER 3: VIEW TIMER MODE
CHAPTER 4: USER PROGRAMMING
4.0 PIN CODE EDIT
4.0.1 MASTER USER
4.0.2 USER
4.0.3 GUEST
4.0.4 DURESS
4.0.5 TIMER
4.0.5.1 IO ON
4.0.5.2 IO OFF
4.0.5.3 ARM
4.0.5.4 DISARM
4.0.6 CLOCK
4.0.7 INSTALLER ACCESS
4.0.8 FAST KEY ACCESS
4.0.9 PHONE LINE LOSS DETECTION
CHAPTER 5: KEYPAD SETTINGS
5.1 DOOR CHIME
5.2 KEYPAD SETTING VIEW
15
15
16
17
18
20
20
20
21
21
22
22
22
23
23
23
24
24
25
26
26
26

AX1 LED User Manual Rev 1.0
CHAPTER 6: WHEN THERE IS AN EMERGENCY
6.0 EMERGENCY ALARM
6.1 DURESS ALARM (CALLING FOR HELP)
6.2 TAMPER LOSS AND PHONE LINE LOSS ALARM
6.3 SYSTEM ALERT TO USER THROUGH TELEPHONE
6.3.1 WITH VOICE ACTIVE
6.3.2 WITH BEEPER
CHAPTER 7: SYSTEM CHECKING
7.0 TROUBLE VIEW
7.0.1 QUICK TROUBLE VIEW
7.1 TESTING SYSTEM
7.1.1 LOCAL SYSTEM TEST (WALK TEST)
7.1.2 BELL TEST
7.1.3 MANUAL TEST REPORTING FOR CMS
7.1.4 BATTERY TEST
GLOSSARY
LIMITATIONS
SYSTEM INFORMATION
QUICK REFERENCE
27
27
27
27
28
29
30
31
31
31
32
32
32
32
32
33
34
35
37

AX1 LED User Manual Rev 1.0
PREFACE
Thank you for selecting the new AX1 system. This manual will explain to you on how to
operate your AX1 alarm and home automation system. This system is made up of a control
panel, keypads, integrated switch module and telephone voice module. Specific areas of
detections are called zones. Zones can be programmed to have different characteristics. Some
zones may be 24-hour zones; they remain armed even when the alarm system is in disarm
mode. (This setting is done during the installer programming as per user‟s request). In
addition, some zones can be programmed by the users to allow zone bypassing. When you
bypass a zone, the zone is temporarily removed from the alarm system. But always remember
that bypassed zones are not protected.
How your AX1 alarm and home automation system works?
When a detection device is triggered, the zone indicator will light up. If the alarm system is
armed, the control panel responds by reporting an alarm condition. The control of the system
can be done either through keypad or telephone. If the alarm system is triggered, the signal
can be transmitted to a central monitoring station (CMS). (Provided the AX1 system is
connected to CMS)
For safety purposes, the operation of the AX1 system requires the users to enter the personal
identification number (PIN). User is advised to disable the installer access whenever
necessary. (i.e. after the commissioning and servicing of alarm system.)
1

AX1 LED User Manual Rev 1.0
FEATURES
AX1 LED
1. 8 fully programmable zones
2. Expandable up to 8 output controls (with feedback capability)
3. Supports up to 4 LED keypads
4. 1 Real time ARM/DISARM timer on Daily Basis only.
5. 4 Real time ON/OFF timer on daily basis
6. 7 user codes & 1 guest code
7. 3 Soft Zones (Emergency/Fire/Panic)
8. 2 Programming Mode- Installer Programming and User Programming
9. 5 User Arming type (Auto home arming/ Day arming/ Away arming/ Force arming/
Night arming)
10. Real time clock function
11. Programmable Entry/Exit Delay Time
12. 4 bell types (Steady/ Pulse/ Chirp/ Silent)
13. 3 zone types [End-of-line (EOL) / Normally Open (NO) / Normally Close (NC)]
14. Adjustable loop response sensitivity
15. Resetable auxiliary power supply upon Alarm Clearing
16. Key Switch function (Latch/ Momentary)
17. Dedicated Tamper zone
18. AC power supply monitoring
19. Low battery indication
20. Short circuit indication & protection
21. Bell Loss indication
22. Bell Test function
23. Telephone line loss detection
24. Programmable Event Reporting Code
25. Telephone Voice Module
26. RS485 ready (to support longer distance communication)
27. Report events to 4 phone numbers with 4 account numbers
28. Ademco® Contact ID CMS reporting format
29. Voice reporting format (direct to user) or tone reporting format
30. Interactive Voice menu or tone beepers during user call in
31. Support Remote programming via touch tone telephone
32. Programmable event trigger
2

AX1 LED User Manual Rev 1.0
33. Fast Key on Keypad for Easy menu access
34. Duress code
35. Walk test function
36. Double Call-in Feature for Fax Machine telephone line sharing
37. 16 Event Trigger Outputs with programmable countdown timer
3

LED KEYPAD OUTLOOK
Key Indication
Auto-Home Arming /
Testing
Day Arming / Keypad
Setting
Night Arming / View
Timer
Fire
Force Arming
Home Automation
Clear Alarm Memory
Emergency
Door Chime on/off
View Trouble
Zone Bypass Mode
Panic
Cancel
Enter
Command
4
ZONE
STATUS
INDICATORS
SYSTEM STATUS
INDICATORS
Power –Green
Armed –Red
Service –Yellow
KEYPAD
ACCESS

AX1 LED User Manual Rev 1.0
ARMING MODE
Arming Type
Zone Status
Information
When To Use
Auto home
Arming
Normal Status
To arm the system with delay time in
order for the user to exit the house
To arm the system in delay time with the
interior zone bypassed provided that the
user does not leave the premises
When user
leaves the house
and no one is at
home.
Day Arming
Normal Status
The perimeter zone is armed instantly
while the user stays at home
The interior zones are automatically
bypassed
When user is at
home.
Away Arming
Normal Status
To arm the system instantly through
telephone when the user are away from
the house.
The interior zones are not bypassed
When user are
outside.
Force Arming
Normal Status
or
Abnormal
Status
To force arm the system instantly
regardless of the zone status.
The interior zones are not bypassed
When there are
zone still open &
user is at home.
Night Arming
Normal Status
The perimeter zone is armed instantly
while user stays at home.
The interior zones are automatically
bypassed. The delay zones become instant
zones.
When everyone
come back to
home & user
want to sleep.
NOTE:
Zone refers to the designated areas that are protected by the AX1 system. Zone status refers to the
condition of the area. Normal status means door, window or detectors are in good/close condition.
While abnormal status means the door/window may have been opened or the detector is not
functioning.
SOUND INDICATION
Sound Indication
Description
Acceptance / Acknowledgement tone
2 fast beeps
Error tone
Continuous buzz for about 2 seconds
Entry delay
Continuous beeping, fast beep for the last 10 sec
Exit delay
Continuous slow beep, fast beep for the last 10 sec
Door chime
Continuous tone for about 2 seconds
Alarm
Chirp (1 second ON/ 4 seconds OFF)
Pulse (2 seconds ON/ 2 seconds OFF)
Continuous Tone
Silent
5

AX1 LED User Manual Rev 1.0
LIGHT INDICATION
AX1 LED Keypad Display’s Reference Table
NOTE:
* : When AC power ON, LED is ON; When AC power failure, LED is OFF
** : When armed, LED = ON
When Emergency/Fire/Panic, LED = Flash
When disarmed, LED = OFF
*** : When trouble occurs, LED is ON; when no trouble occurs, LED is OFF
Flash : 0.5 second ON, 0.5 second OFF
Fast flash : 0.1 second ON, 0.1 second OFF
KEYPAD NAVIGATION KEY FUNCTION
[COM] Key : Command
[#] Key : Enter
[*] Key : Cancel
No
Description
Power
Armed
Service
Zones
1
Normal Mode
*
OFF
***
Pending
2
Arming
*
ON
***
Pending
3
Home Automation
Mode
Flash
OFF
Flash
Pending
4
User Programming
Mode
Flash
Flash
Flash
Pending
5
AC power failure
OFF
**
ON
Pending
6
Trouble occurs
*
**
ON
Pending
7
View Trouble Mode
*
**
Flash
ON according to the type
of trouble
8
Zone Status
(Triggered)
(Bypassed)
(Alarmed)
*
*
*
**
**
**
***
***
***
ON
Flash
Fast flash
9
Tamper zone triggered
*
Fast flash
***
All zone‟s LEDs
Fast flash
10
Telephone line loss
alarm triggered
*
Fast flash
Fast flash
Pending
11
Walk test
*
Flash
Flash
Pending
6

AX1 LED User Manual Rev 1.0
[CHAPTER 1] ALARM SYSTEM CONTROL
1.0 USING LED KEYPAD
1.0.1 ARMING
1.0.1.1 QUICK ARMING
Command
Information
Press and hold the button [
]for 2 seconds
Auto Home Arming
Press and hold the button [ ] for 2 seconds
Day Arming
Press and hold the button [ ] for 2 seconds
Night Arming
Press and hold the button [ ] for 2 seconds
Force Arming
7
Press [User
PIN] and #
Exit delay starts
to count down
with sound.
Press [User
PIN] and hold
[ ] for 2 sec.
Press [User
PIN] and hold
[] for 2 sec.
Press [User
PIN] and hold
[ ] for 2 sec.
System is now armed.

AX1 LED User Manual Rev 1.0
1.0.2 DISARMING
1.0.2.1 IN ARMED/ALARM MODE
Command
Information
To disarm the system, press
[User PIN] [#].
The keypad will beep twice upon
confirmation. Otherwise, the error tone will
sound if PIN numbers are entered wrongly.
The ARMED light will go OFF once the
system is disarmed.
8
System is now disarmed
Press [User PIN] [#]
to disarm

AX1 LED User Manual Rev 1.0
1.0.3 ALARM REPORT
When alarm occurs, the strobe lights and the bells will be turned ON. If the system is
disarmed, it could only turn OFF the bell but not the strobe light. Zone LED fast flashes
indicate that the designated zone has been triggered by alarm.
During the state of alarm, only PIN entry is allowed. In other words, only DISARM is
allowed.
1.0.4 CLEAR ALARM MEMORY
When alarm occurs, the strobe lights and the bells will be turned on. If the system is
disarmed, it could only turn off the bell but not the strobe light. Thus, the user needs to clear
the alarm memory to turn OFF the strobe light. Besides that, once the alarm memory is
cleared, the auxiliary power supply 1 will be reset for 3 seconds before restoring it again.
9
Press and hold
[ ] for 2 sec.
Alarm Cleared

AX1 LED User Manual Rev 1.0
1.0.5 BYPASSING ZONE
Bypassing a zone means removal of one or more protection zones from the system. In order
to perform bypassing, the system must be in normal mode. Once the system is disarmed, the
entire zone will be unbypassed.
1.0.5.1 QUICK BYPASSING ZONE
Command
Information
Press and hold for 2 seconds
Bypassing zone
10
Press and Hold for 2 sec.
Screen will show the current
bypassed zone status. Zone
LED turn ON to indicate
zones are bypassed.
To toggle ON/ OFF, press
relevant zone number (1 to 8).
Press to return back to
normal mode.

AX1 LED User Manual Rev 1.0
1.1 ARM/DISARM USING TELEPHONE
The AX1 alarm system is designed with the feature which allow system control by using
telephone, there are two methods. Firstly is using voice guided if voice module is installed into
the system and secondly is guided by beeper.
1.1.1 ARM/DISARM WITH VOICE ACTIVE
Press [1]
If wrong input key
Press [Master PIN] [ # ]within 1 minute
Correct Code
Invalid Code
Press [0]
Press [0]
Press [0]
Press [0]
System hangs up
Press [#]
Press [#]
Press [#]
Only 3 attempts
allowed.
System hangs up
Press [#]
Press [0]
Incorrect code!
Please enter your code
Main Menu
Press
1 for Security Menu
2 for Automation Menu
0 to Exit
Security Menu
Press
1 to ARM
2 to DISARM
# for Main Menu
0 to Exit
Arming Menu
Press
1 to arm Partition 1
# for Main Menu
0 to Exit
* AX1 LED only support
partition 1
Press [1]
Arming accepted.
Press
# for Main Menu
0to Exit
Thank you
Welcome
Please enter your code.
You are not an
authorized user. System
will now exit.
Arming Mode Menu
Press
1for Auto Home Arming
2for Night Arming
3for Day Arming
4for Away Arming
5for Force Arming
# for Main Menu
0to Exit
Invalid Input
If arming accepted,
keypad shows:
Press [1] to [5]
Press [1]
11

AX1 LED User Manual Rev 1.0
1.1.2 ARM/DISARM WITH BEEPER (Without voice module)
Press [Master PIN] [#] within 1 minute
Correct Code
Invalid Code
Acknowledgement
Tone (Beep Twice)
Error Tone
(Long Beep)
To arm the system with Auto Home Arming,
Press [1] [0] [1] [#]
To arm the system with Away Arming,
Press [1] [1] [1] [#]
To arm the system with Day Arming,
Press [1] [2] [1] [#]
To arm the system with Night Arming,
Press [1] [3] [1] [#]
To arm the system with Force Arming,
Press [1] [4] [1] [#]
To DISARM
Press [2] [1] [#]
Press [0] [#]
System
Hangs up
Acknowledgement
Tone (Beep Twice)
Error Tone
(Long Beep)
Invalid Code
Correct Code
5 Slow Tones
Only 3 attempts
allowed.
If arming accepted,
keypad shows:
12

AX1 LED User Manual Rev 1.0
2.0 INTRODUCTION
The system can support up to 8 outputs and can be controlled during system in normal and
armed state only. The outputs can be electrical appliances such as air-conditioners, fans or
lights. The outputs can be configured as event-triggered outputs or normal outputs which are
controlled either by LED keypad, real time clock timer or telephone remote control.
Recommended air conditioner with memory backup or last state memory in Malaysia is as
below:
Wall Mounted Split Air Conditioner (Brand : Acson)
Model: AWM101 –(1.0 HP)
AWM151 –(1.5 HP)
AWM201 –(2.0 HP)
AWM251 –(2.5 HP)
AWM301 –(3.0 HP)
Ceiling Cassette Split Air Conditioner (Brand : Acson)
Model: ACK15B –(1.5 HP)
ACK20B –(2.0 HP)
ACK25B –(2.5 HP)
ACK30B –(3.0 HP)
CHAPTER 2: HOME AUTOMATION CONTROL
13

AX1 LED User Manual Rev 1.0
2.1 HOME AUTOMATION CONTROL USING LED KEYPAD
Press and hold for 2 sec
Press the relevant module number
(1 to 8) to toggle output
Zone LED will show the current
output status.
Press [ 0 ] to ON all outputs
Press to return back to
normal mode.
Zone LED turn ON to indicate
outputs are on.
14
Press [ 0 ] again to OFF all
outputs

AX1 LED User Manual Rev 1.0
2.2 HOME AUTOMATION CONTROL USING TELEPHONE
For home automation control by using telephone, there are two methods. One is using voice
guided if voice module is installed into the system and secondly is guided by beepers.
2.2.1 WITH VOICE ACTIVE
15
Welcome
Please enter your code.
Incorrect code!
Please enter your code
Main Menu
Press
1for Security Menu
2for Automation Menu
0to Exit
Press [Master PIN] [#] within 1 minute
Correct Code
Invalid Code
Press [2]
Automation Menu
Press
1to ON Output
2to OFF Output
3to ON ALL Output
4to OFF ALL Output
#for Main Menu
0to Exit
Press
01 for Output 1
02 for Output 2
03 for Output 3
04 for Output 4
……
08 for Output 8
#for Main Menu
0to Exit
Press [1] to [4]
(All) Output # is now ON /OFF
Press
#for Main Menu
0to Exit
Press [x] [x]
Thank you
Press [0]
Press [0]
Press [0]
Press [0]
System hangs up
Press [#]
Press [#]
Press [#]
Table of contents
Other O.Y.L. Technology Security System manuals