O3 ehanddryers Sterizen X4 User manual

Contents
Install & Operation Manual
EN
2Introduction
3 Technical Specication
3 X4 Dimensions
4 X5 Dimensions
5 Electrical Diagram
6 Installation
6 Major Components
7 Before Installation
7 Mounting
8 Commissioning
9 User Instructions
9 Operation
9 Functions and Control
10 Maintenance
10 Relling the X4 X5 Unit
11 Replacing the Batteries
12 Silicone Hose and Outlet
12 Stainless Steel Care
14 Fault Finding
15 Spares

X4 & X5 Install & Operation Manual 500475 v051120Sterizen EN2
Introduction
Models
The X4/X5 model is a free standing hand sanitiser station. It is a self-contained machine with a robust stainless
steel frame cabinet and an attractive acrylic front.
This hand sanitiser unit is manufactured to the highest standards and has been designed to meet all the latest
relevant safety specications. Please read and understand these instructions before starting work. Please leave
these instructions with the user following installation. Particular attention should be paid to the section headed
installation.
The hand sanitising station must not be sited outside or in any location where it could be exposed to the
weather. It must be installed in a dry environment.
In the Box - X4
- X4 Unit
- Base with xing screws
- 4 x Adjustable Feet
- 1 x Hand Sanitiser Container
- 4 x C Type Batteries
In the Box - X5
- X5 Unit
- Base with xing screws
- 4 x Adjustable Feet
- 2 x Hand Sanitiser Containers
- 8 x C Type Batteries
4 x 1.5V +
8 x 1.5V +
4 x 1.5V +
8 x 1.5V +

X4 & X5 Install & Operation Manual 500475 v051120Sterizen EN3
Technical Specication
360mm
353mm
1387mm
102mm
1110mm
ø250mm
X4 Dimensions

Sterizen EN4X4 & X5 Install & Operation Manual 500475 v051120
360mm
710mm
1110mm
ø250mm
353mm
1387mm
102mm
Technical Specication
X5 Dimensions

Sterizen EN5X4 & X5 Install & Operation Manual 500475 v051120
Technical Specication
Electrical Diagram
WIRE COLOUR LEGEND
B R
B
R
Red
BlackB
R
PCB
RB
6V Pump
RB
PCB
RBRB
6V Pump
6V Battery
6V Battery
Barell Jack

X4 & X5 Install & Operation Manual 500475 v051120Sterizen EN6
Major Components
1ACRYLIC PANEL 5ADJUSTABLE FEET
2DISPENSE OUTLET 6SERVICE PANEL
3TOP APERTURE 7ACCESS PANEL LOCK
4LOWER APERTURE 8POWER JACK SOCKET
Installation
1
2
3
5
8
4
7
6
Note: Model shown is X5

Sterizen EN7X4 & X5 Install & Operation Manual 500475 v051120
Before Installation
Mounting
Due to it being battery operated the X4/X5 is a free standing model designed to t in any space. Where it
requires to be mains powered ensure there is a nearby power socket.
Before installation allow adequate space to install the appliance. Rear access is required to rell the unit or
change the batteries.
12
The cabinet can then be levelled using the 4
adjustable feet on the underside of the base.
Lay down the cabinet on its side on
a soft surface to avoid scratching. Fit
the base to the underside of the unit
and x with the 4 screws provided.
Note: Ensure the grommet is located to the
rear of the unit.
Installation

X4 & X5 Install & Operation Manual 500475 v051120Sterizen EN8
Commissioning
123
5
4
Sit the containers into the
base. Remove the lids and
peel back the safety cap.
Insert the hoses into the
containers ensuring they are
pushed to the bottom.
Fit rear panel back on and
lock.
Remove the rear access cover
located at the rear of the unit
by unlocking the catch and
then lifting up the cover.
NOTE: PLEASE REFER TO PAGE 11 FOR FULL INFORMATION ON BATTERY OPERATION.
For rst time use it is required to prime the pump so the sanitiser gel is close to the outlet. To do this,
repeatedly place your hands under the sensor until the unit starts to dispense the sanitiser gel.
The unit is now ready for use.
Insert the provided batteries
into the battery holder. Take
care to ensure all batteries
are inserted with the correct
polarity as shown inside the
battery compartment.

X4 & X5 Install & Operation Manual 500475 v051120Sterizen EN9
Operation
The X4/X5 is a touchless operation unit.
To operate you simply place your hands through the centre of either the top or bottom aperture to dispense the
hand sanitiser. A blue LED indicator will light up when in operation.
Function and Controls
User Instructions
Dispense Outlet
Sensor
Blue LED Indicator

X4 & X5 Install & Operation Manual 500475 v051120Sterizen EN10
Maintenance
Relling the X4 X5 Unit
The X4 X5 has been designed so it can be quickly and easily relled. To do so please follow the below
instructions.
1
3
2
Remove the rear access cover located at the
rear of the unit by unlocking the catch and
then lifting up the cover.
Fit rear panel back on and lock.
Remove silicone hoses and either replace the
sanitiser containers or top up as required.
Insert the hoses back into the bottom of the
containers.

Sterizen EN11X4 & X5 Install & Operation Manual 500475 v051120
Replacing the batteries
Battery Operation
1. Remove the rear access cover located at the rear of the unit by unlocking the catch and then lifting up the
cover.
2. Insert four C Type batteries into the spaces in the compartment. Take care to ensure all batteries are
inserted with the correct polarity as shown inside the battery compartment.
3. If the pump or LED starts to stutter or stop this is signs that the batteries may need replacing.
4. If the unit is not to be used for any extended period of time it is recommended that the batteries are
removed from the unit.
Caution: Replace batteries only with the same or equivalent type. Danger of explosion if the batteries are
incorrectly replaced.
13
2
Correct disposal of the batteries in this product
(Applicable in countries with separate collection systems)
This marking on battery, manual or packaging indicates that the batteries in this
product should not be disposed of with other household waste at the end of their
working life. If batteries are not properly disposed of, these substances can cause harm to
human health or the environment.
To protect natural resources and to promote material reuse, please separate batteries
from other types of waste and recycle them through your local, free battery return
system.

Sterizen EN12X4 & X5 Install & Operation Manual 500475 v051120
Silicone Hose and Outlet
If left for a sustained period of time the hand sanitiser gel can start to congeal in the hoses and around the
stainless steel outlet. Regular cleaning of these components will help improve performance. To do this simply
disconnect the hoses and clean through with warm water. The outlet can be easily cleaned in situ.
Care and Maintenance of Stainless Steel
Introduction
All grades of stainless steel will stain and discolour due to surface deposits and can never be accepted as
completely maintenance free. In order to achieve maximum corrosion resistance the surface of the stainless
steel must be kept clean. Provided the grade of stainless steel and the surface nish are correctly selected,
and cleaning schedules carried out on a regular basis, good performance and long service life are assured.
Factors Affecting Maintenance
Surface contamination and the formation of deposits must be prevented. These deposits may be minute
particles of iron or rust from other sources used on the building of new premises and not removed until after
the stainless steel items have been xed. Industrial and even naturally occurring atmospheric conditions can
produce deposits which can be equally corrosive, e.g. salt deposits from marine conditions.
The working environment also offers more aggressive conditions e.g. hot humidity, such as in a swimming pool,
increases the speed of discolouration and therefore requires the maintenance to be on a more frequent basis.
Modern processes use many cleaners, sterilizers and bleaches for hygienic purposes. All these proprietary
solutions, when used in accordance with makers instructions are safe but if used incorrectly (e.g. warm or
concentrated) can cause discolouration and corrosion on the surface of any quality of stainless steel. Strong
acid solutions are sometimes used to clean masonry and tiling of buildings, but they should never be permitted
to come into contact with metals, including stainless steel. If this should happen the acid solution must be
removed immediately and copious applications of water.
Maintenance Programme
With care taken during fabrication and installation, cleaning before handling over to the Client should
present no special problems, although more attention than normal may be required if the installation period
has been prolonged. Where surface contamination is suspected, immediate attention to cleaning after site
xing will encourage a trouble-free product. Food handling, pharmaceutical, aerospace and certain nuclear
applications require extremely high levels of cleanliness applicable to each industry.
Advice is often sought concerning the frequency of cleaning stainless steel and the answer is quite simple
“clean the metal when it is dirty in order to restore its original appearance”. This may vary from once to four
times a year for external applications or it may be once a day for an item in hygienic or aggressive situations.
Frequency and cost of cleaning is lower with stainless steel than with many other materials and will often
outweigh the initial higher cost of this superior product.

Sterizen EN13X4 & X5 Install & Operation Manual 500475 v051120
Precautions
Acids should only be used for on-site cleaning when all other methods have been proved unsatisfactory.
Rubber gloves should be used and care taken to see that acid cleaners are not spilt over adjacent areas.
Special precautions are necessary with oxalic acid. Solvents should not be used in closed places. Smoking
must be avoided when using solvents.
PROBLEM CLEANING AGENT COMMENTS
Routine cleaning Soap or mild detergent and water. (Such as Fairy
Liquid) Sponge, rinse with clean water,
wipe dry if necessary
Fingerprints Soap or warm water or organic solvent (e.g. Usher/
Walker Thinners No PF8017, acetone, alcohol). Rinse with clean water, wipe dry if
necessary
Stubborn stains and
discolouration Mild cleaning solutions i.e Jiff, Goddard Stainless
Steel Care Rinse well with clean water, wipe
dry if necessary
Rust and other
corrosion products.
Oxalic Acid. The cleaning solution should be ap-
plied with a swab and allowed to stand for 15-20
minutes before being washed away with water. May
continue using Jiff to give nal clean
Rinse well with clean water.
(precautions for acid cleaners
should be observed)
Scratches on surface
Slight scratches. Impregnated nylon pads. Polishing
with scuffs dressed with iron free abrasives. For
deeper scratches; apply in direction of polishing.
Then clean with soap or detergent as per routine
cleaning
Do not use ordinary steel wool
- iron particles can become
embedded in stainless steel and
cause further surface problems

X4 & X5 Install & Operation Manual 500475 v051120Sterizen EN14
Fault Finding
Problem/Report Possible Cause Suggested Action
No sanitiser dispenses
Sanitiser container empty Check and rell sanitiser
container.
Pump not working Check probes connected/
Leads attached. Check power
supply to pump.
No electricity/power supply Check batteries and replace if
necessary. Check power cord
is connected and live.
Blocked outlets/pipes Check and unblock or replace
as needed.
Sensor PCB not working Check/replace control PCB
Sanitiser lying in machine
Leak from outlet Locate and repair accordingly
Faulty sensor Locate and repair accordingly
If you need further assistance, please contact our technical support team.

X4 & X5 Install & Operation Manual 500475 v051120Sterizen EN15
Spares
700859
700614
700693 700820
700840
700729
700885
700652
700842

Sterizen EN16X4 & X5 Install & Operation Manual 500475 v051120
Parts List
Accessories List
Sterizen
Part No
Description
500679 1L Rell Container - Mighty Mint
500680 1L Rell Container - Energy Rush
500681 1L Rell Container - Citrus Zest
500682 1L Rell Container - Magenta Sky
700928 AC Mains Adapter
700899 Floor Fixing Kit
Sterizen
Part No
Description
700614 6V Pump with Connector Joints
700693 Stainless Steel Outlet
700820 Outlet Locking Nut
700859 Control Board with Sensor and LED
700840 PCB Mounting Supports
700885 Emka Lock and Cam
700729 Rear Access Door
700842 Adjustable Feet x 4
700652 Base Plate
700830 Silicone Hose
This manual suits for next models
1
Table of contents