Objecto A2 User manual

USER MANUAL
AromaA2W2.indb1AromaA2W2.indb1 2016/12/1615:44:122016/12/1615:44:12

2
English
Safety Information
Before use, be sure to carefully read this information on safety to ensure that you use this•
product correctly.
This section presents important safety information. Always follow this information when using•
this product.
After reading this information, keep it in a safe, easily accessible place to the user.•
WARNING
Do not scratch, damage, modify, forcibly bend, pull, twist, or bind the
power cord, or place heavy objects on or clamp the power cord.
This could damage the power cord and result in a fire or electrical shock.
Do not use when the power cord or AC adapter is damaged, or the
plug is inserted loosely into the outlet.
This can result in an electrical shock, short-circuit, or start a fire.
Do not allow children to use this product by themselves, and keep out
of the reach of small children.
Otherwise, this could result in an injury or electrical shock.
Do not insert metal objects, such as pins, wires, or other foreign
objects inside the gaps in the product.
This can result in an electrical shock or injury.
Do not disassemble. This product may only be disassembled by
qualified repair technicians.
Attempting to disassemble this product can cause a fire, electrical shock, or injury. To
request repair, please contact your dealer or our FACTORY SERVICE CENTER (see the
back cover).
CAUTION
When cleaning the product, be sure to unplug the AC adapter from
the outlet as a safety measure.
Do not use in locations with high humidity (85% or higher).
Do not use in locations where the mist directly contacts furniture,
walls, curtains, ceiling, or other objects.
Do not place on slanted surfaces, high locations such as bookshelves,
or on unstable surfaces.
Do not block the mist outlet.
Use clean water only.
AromaA2W2.indb2AromaA2W2.indb2 2016/12/1615:44:122016/12/1615:44:12

3
English
Do not use hot water.
Use of hot water that is 104°F or higher can cause deformation or malfunction of the
product.
Do not use the product by placing it directly onto a carpet or other
object with soft fibers.
When unplugging the AC adapter, always unplug by grasping the AC
adapter, not by pulling on the power cord.
Discard the water when not using the product.
Replace the water in the water tank with new water everyday. Clean
regularly to ensure that the inside of the product is always clean.
Do not place cell phones, computers, or other electronic devices near
the product.
Be careful that the product does not freeze.
Do not tilt the product.
If you leave water in the water tank and tilt the body, the water may spill.
This appliance is not intended for use by persons (including children)
with reduced physical, sensory or mental capabilities, or lack of
experience and knowledge, unless they have been given supervision
or instruction concerning use of the appliance by a person responsible
for their safety.
Children should be supervised to ensure that they do not play with
the appliance.
If the supply cord is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualified persons in order
to avoid a hazard.
AromaA2W2.indb3AromaA2W2.indb3 2016/12/1615:44:122016/12/1615:44:12

4
English
Names of Parts and Their Functions
Mist outlet
Cover
Aroma diffuser
MAX line (capacity: 80 ml)
Fan outlet
Ultrasound vibration plate (ceramic disc)
Water tank
Drain direction (pour spout)
CAUTION
Drain water from the water tank prior to moving the diffuser.
AromaA2W2.indb4AromaA2W2.indb4 2016/12/1615:44:122016/12/1615:44:12

5
English
Accessories
AC adapter
Power cord
Plug
Measuring cup
The water level scale is printed*
on both sides. Use the 80 ml cup
measurement.
Correct Use of the Aroma Diffuser
Preparation Before Use
Remove the cover from the body.1.
Cover
AromaA2W2.indb5AromaA2W2.indb5 2016/12/1615:44:122016/12/1615:44:12

6
English
Insert the plug of the AC adapter into its socket.2.
Plug
Plug socket
Place the diffuser on a flat, level, stable surface.3.
CAUTION
Place the diffuser at least 6.5 ft. from televisions, radios, and other
electronics.
Otherwise, static interference can result.
Fill with water.4.
Fill the measuring cup with 80 ml of room temperature clean water.1
Pour water from the measuring cup into the water tank up to its MAX line.2
Put two or three drops of your favorite aroma or essential oil into the tank.3
Put the cover back in place, wipe up any spilled water and make sure there are no leaks.4
Measuring cup
Oil bottle
Measuring cup
MAX line
AromaA2W2.indb6AromaA2W2.indb6 2016/12/1615:44:122016/12/1615:44:12

7
English
Handling of aroma and essential oils
Do not expose the oils to open flame.• Store in a location that is out of the reach of children.• If oils are spilled on clothes or other objects, rinse with a lot of water and allow to air dry.• Do not use a dryer. This could cause the object to ignite.
If any oil gets on your hands, wash them immediately.• For further details about the handling of aroma and essential oils, refer to the supplied• manual.
Keep the diffuser an appropriate distance from walls and
surrounding objects
Pay attention to the following points when using the diffuser.
At least 20 inches above the diffuser
At least 8 inches to the left At least 8 inches behind
At least 8 inches to the right
At least 8 inches in front
Do not place on carpets or other materials with a thick pile. These could block the air•
inlet and result in a malfunction of the device or leak to the surrounding area.
•
Never place cell phones, computers, or other electronic devices that are sensitive to
humidity near the diffuser.
AromaA2W2.indb7AromaA2W2.indb7 2016/12/1615:44:122016/12/1615:44:12

8
English
AC adapter
WARNING
If you are going outside or will be away from the diffuser for an extended period of time,
unplug the AC adapter from the outlet.
CAUTION
Use clean water only.• Do not lift up or tilt the diffuser while it is working.• Do not put water in the fan outlet.•
This could result in malfunction. If water gets in the fan outlet, immediately turn
the diffuser off and unplug the AC adapter from it. Then drain the water from
the water tank, wipe it with a dry cloth. Shake the diffuser well to get moisture
out of the air inlet and then let the unit sit at room temperature to dry for at least
24 hours before using it again.
Take care not to get aroma or essential oils on anything except the inside of the water tank.•
Immediately wipe them off if they get on anything else.
Do not fill directly from a faucet.•
Starting and Stopping Operation
Starting operation1.
Once you press the LIGHT button, the diffuser turns on and the LED lamp lights up.1
If you press the MIST button, the CONT. lamp lights and the diffuser starts in continuous2 operation. If you press the MIST button again, the 10SEC. lamp lights and the mist starts the
intermittent operation.
After making sure the AC adapter is securely plugged in, start the diffuser.*
Stopping operation2.
Pressing the LIGHT button again turns the LED lamp off.1
Pressing the MIST button again stops diffuser operation.2 When the water in the water tank gets low, mist operation stops automatically.
MIST button
LIGHT button
AromaA2W2.indb8AromaA2W2.indb8 2016/12/1615:44:122016/12/1615:44:12

9
English
CAUTION
When removing the cover after operation, water drops inside the cover may
drip. Wipe the wet part or floor with towels if they get wet.
Continuous
operation
Intermittent
operation Stop
Cleaning and Storage
WARNING
Do not touch the metal parts inside the aroma diffuser. This could result in an injury or• malfunction.
Before cleaning, always stop operation, unplug the power cord, and drain the water inside• of the water tank as indicated by the drain direction arrow.
Cleaning the Aroma Diffuser
Fully drain the water left inside the water tank.1
* When discarding the water, pour it from the pour spout, so no water gets into
the fan outlet.
* If water gets into the fan outlet, it may cause malfunction.
* Drain the water, and dry thoroughly.
Wipe the ultrasound vibration plate (ceramic disc: white part in the middle) and metal parts with2 a disinfecting alcohol-soaked cotton swab.
Cotton swab
MAX line
Pour spout
Storage
Perform care and cleaning by following the procedures in “Cleaning the
Aroma Diffuser”, and fully wipe up any moisture inside the water tank,
and then allow it to dry completely in the shade. Put in a plastic bag then
pack it back in the original product box with the User’s Manual and store
in a place with low humidity.
AromaA2W2.indb9AromaA2W2.indb9 2016/12/1615:44:122016/12/1615:44:12

10
English
CAUTION
Do not wipe with benzene or thinner. This could result in discoloration or deformation.• Before using a cloth containing chemical substances, check its safety information.• Otherwise, discoloration or scratches could result.
Replace the water in the water tank with new water everyday. Clean regularly to ensure• that the inside of the water tank is always clean.
Use clean water only.• Never use juice or other drinking fluids, hot water (104°F or higher), or water mixed with• chemical products, or cleanser.
This could damage the aroma diffuser.
AromaA2W2.indb10AromaA2W2.indb10 2016/12/1615:44:122016/12/1615:44:12

11
English
Before Requesting Repairs or Service
WARNING
This product can be disassembled and repaired by qualified repair
technicians only.
If you find any problems, follow the troubleshooting procedures below.
Problem Primary cause Solution
The power does not
turn on. The AC adapter is•
unplugged from the outlet.
Plug the AC adapter into the outlet.•
It does not work. No water in the water tank.• Fill with water.•
It smells of something
other than a
fragrance.
Using water other than•
clean water.
Drain the water left in the water•
tank, and clean by following
the procedure in “Cleaning and
Storage”.
Specifications
Product name Aroma Diffuser
Model AD-18
Power supply AC adapter 24 V dc (Use the specified AC adapter)
Power consumption 10.5 W (including AC adapter)
Water tank capacity 80 ml
External dimensions 4.5 inches Dia. × 5.7 inches H.
Weight 0.5 lb. (body only)
Accessories User’s Manual × 1, AC adapter × 1, Measuring cup × 1
Due to a continuous process of product improvement, the specifications and other information*
are subject to change without notice.
AromaA2W2.indb11AromaA2W2.indb11 2016/12/1615:44:122016/12/1615:44:12

12
English
LIMITED WARRANTY POLICY
Thank you for selecting our Products.
Please carefully read the User’s Manual furnished with this product. We believe that you will be very
satisfied with your purchase. We will provide the following LIMITED WARRANTY to you as the original
purchaser.
Should service be necessary for any reason due to manufacturing defect or malfunction during the
1 year warranty period, OBJECTO will provide carry-in repair service, no charge, at our FACTORY
SERVICE CENTER below:
Pack the unit in a well padded heavy corrugated box. Be certain that the unit is well protected.a) Enclose your check or money order payable to H.S.I REPAIR CORP, in the amount of $20.00 tob) cover return postage.
Enclose copy of proof of purchase.c) Ship the unit prepaid via UPS or parcel post insured.d)
NOTE: This warranty does not cover.
OBJECTO products which have been damaged by negligence, misuse or accident or which havea) been modified or repaired by anyone other than our FACTORY SERVICE CENTER.
Damage to OBJECTO equipment that has been improperly connected to the equipment of otherb) manufacturers
Costs incurred in the shipping of OBJECTO products to our FACTORY SERVICE CENTER.c)
This warranty is valid only to the original purchaser and does not extend to owners of the product
subsequent to the original purchaser. Under no circumstances shall OBJECTO be liable for any loss or
damage, direct or consequential, arising out of the use of, or inability to use this product. (Some states
do not allow limitation or implied warranties or exclusion of consequential damage, therefore these
restrictions may not apply to you.)
This warranty gives you specific legal rights and you may also have other rights which may vary from
state to state.
The Limited Warranty Registry Card must be completely filled out and mailed immediately, in ordera) to validate the Limited Warranty.
You must include copy of your purchase slip when you are returning the unit.b)
Register your new product online at WWW.OBJECTO.com
SERVICE INFORMATION:
OBJECTO
935 BROADWAY, 6TH FL.
NEW YORK, NY 10010
TELEPHONE: 844-OBJECTO
FAX: 800-433-9099
INTERNET WEBSITE ADDRESS: WWW.OBJECTO.COM
ZB16A
AromaA2W2.indb12AromaA2W2.indb12 2016/12/1615:44:122016/12/1615:44:12
Table of contents
Popular Accessories manuals by other brands

Scent Works
Scent Works Aura Purity user guide

Rcom
Rcom KINGSURO MAX 20 user manual

Paradox
Paradox ENVY NVX80 Installation quick guide

Heath Zenith
Heath Zenith 6180 Series user manual

HunterDouglas
HunterDouglas SW Instructions and warnings for installation and use

Astral Pool
Astral Pool HALO ORP installation manual