CALIBRATING SENSORS:
We recommend calibrating during daytime, because in the evening all ora emits CO2, which raises the level of CO2 to 450ppm.
For calibration a level of 400ppm is needed. Before calibration, the sensor needs to be warmed up by inserting it in an electrical output
for at least 5 minutes. The CO2 sensor should be placed in a CO2 neutral environment, like a garden, a balcony or if these are not available,
a sealed and well ventilated room for at least 8 hours. If the value of the sensor is between 370ppm and 420ppm, there is no need to
calibrate the sensor, because the level of CO2 in clean air is between 380ppm and 430ppm. A 5% variance is acceptable for this kind
of measuring equipment. Take this into account when CO2 values are programmed. If the variance is greater than the acceptable values,
the sensor must be calibrated
CO2 AUTO CALIBRATE:
Press setting key, choose “CO2 AUTO CALIBRATE”, then choose YES, press setting key again and return to the main menu.
The “CO2 SENSOR” is now calibrated at 400ppm and ready for use!
CO2 MANUAL CALIBRATE:
Press setting key, choose “CO2 manual CALIBRATE”, the controller will now show the correct
value. You can now calibrate the CO2 value using the up and down key. After conrmation, press setting key and return to the main menu.
If not, please press ESC key.
CO2 SET PPM:
Press setting key, choose “CO2 SET”, press setting key again, you will enter the CO2 setup.
You can now set CO2 using the up and down key. After conrmation, press setting key and
return to the main menu. If not, please press ESC key.
CO2 RATE: 300-2750ppm