Ten digit: function
digitas: data
0
1
1.
0-3 load work mode
0: pure light control
1: light+time control
2: continuation output
3: test mode
0-4. 0-14H×1H
0-0. 0-100% ,increase by 1 0 % ×10%
Function
0-4. 0-14H×1H
0-0. ×10%
2
2.
3
3.
0-4. ×1H
0-0. ×10%
0-4. ×1H
0-0. ×10%
4
4.
1-0. The number of LED in parallel 1-10 parallel
5
6
7
0-9. load current 200-390mA, 10mAincrease by 10 % 200+ digit×10 mA
1-1.
Light ON/O FF th re shold volta ge
1-11V ,(×2/24V) ×1V
0-4. LVD 10.6-12V(precision 0.1V).(×2/24V)
0-9
Turn on the lights delay time 0-27minute ×3,minute
8
9
10.6+ digit×0.1V
0-100% ,increase by 1 0 %
0-14H
0-100% ,increase by 1 0 %
0-14H
0-100% ,increase by 1 0 %
-
-
NOTE:
1. Radix point of LED segment display indicate the value added"10",for example 4.=14
2. Test mode is as same as light control mode but no delay,therefore,test mode is only
used to test load switch. select the other one to exit the test load mode manually.
Digital Display
Ten digit
digits
Function
(Ten digit)(digits)
Function parameters The formula
(digits)
The first period time(H1)
The first period power
The second period time(H2)
The second period power
The third period time(H3)
The third period power
The four period time(H4)
The four period power
Settings
Press the Settings button, the digital tube on, cycle display the current setup parameters,Choose the
functionality you need to set Digital digits flashes, choose the function you need.
the digital tube no flashes when successfully set
The same method to set the next parameter
Short press
long press Short press
wait for tree seconds
LED lamp arrangement method
LED parallel number(K)LED series number(N)LED Power range(P)
5≤N14≤1≤K≤5 P≤30W
System voltage
12V
24V 9≤N14≤1≤K≤5 P≤60W