1
2
A
B
ELECTRICAL CHARACTERISTICS 12V - 15W a.c.
CABLE SIZE Use cable with secon in accordance with the lenght of electric circuit.
ISM-05-00 UR0719
ASSEMBLING INSTRUCTIONS FOR
HORIZONTAL ELECTRIC LOCKS
LATCH REVERSIBILITY Operate the throw “1” with the key, use a screwdriver “A” to unscrew and extract the 2 screws
from
the latch bolt, extract the latch bolt and turn it 180°, then insert it back into the faceplate.
Fig.1
RELOADING PISTON REVERSIBILITY Use a screwdriver “B” as a lever to let out the reloading piston “2”
from the faceplate,
turn it 180° and then release to let it back into the faceplate.
Fig.1
THROW EXCLUSION (except art.1777)
Use a screwdriver to move the lever “3” upward unl it engages.
Fig.1
LATCH REVERSIBILITY Use a screwdriver “A” as a lever to let out the latch bolt “1” from the faceplate, turn it
180° and then release to let it back into the faceplate. Fig.2
RELOADING PISTON REVERSIBILITY Use a screwdriver “B” as a lever to let out the reloading piston “2” from the faceplate,
turn it 180° and then release to let it back into the faceplate.
Fig.2
LATCH REVERSIBILITY Use a screwdriver “A” as a lever to let out the latch bolt “1” from the faceplate, turn it
180° and then release to let it back into the faceplate. Fig.3
RELOADING PISTON REVERSIBILITY Use a screwdriver “B” as a lever to let out the reloading piston “2” from the faceplate,
turn it 180° and then release to let it back into the faceplate.
Fig.3
Art. series 377-388-777-788-877-888-1777
Art. series 788-878
Art. series 799-899-999
CABLE
SECTION mm2 0,75 1,50 2,50 4,00
CIRCUIT
LENGTH m 0 ÷ 50 > 50 ÷ 100 > 100 ÷ 150 > 150
2
1
3
A
B
1
2
A
B
Fig.1
Fig.2 Fig.3