Omega DP20 User manual

To view the DP20 spec sheet and manuals visit us at hps://www.omega.com/pptst/DP20.html
3. Addional documentaon
1. Front view
1. Open the instrument (see secon 7).
2. Select the jumpers for the desired signal range (see secon 8).
3. Close the instrument (see secon 7).
4. Connect the signal and the power (see secon 6).
5.
Congure the instrument
from the ‘
Conguraon menu’ (see secon 9).
6. If you need addional informaon, see secon 3.
5. Installaon and start-up
6. Connecons
7. How to open the instrument
DP20
Model
-
Opon 1
-A1 (1 relay)
-M1 (analog output)
-S1 (Modbus RTU)
-(empty)
-
Opon 2
-A2 (1 relay)
-(empty)
4. How to order
2. Dimensions and panel cut-out (mm)
8. Internal structure and jumpers for range selecon
MQS5802_0618
Key ‘LE’ Key ‘SQ’
1. Exit the menu
Key ‘UP’
1. Enter into ‘Fast access’
2. Next value
Units
Alarm 1 and 2
Fuse
Opon M1 (4/20 mA)Opon A1 (relay)
Protecon fuse value :
250 mA me-lag for power voltage > 50 Vac/dc
400 mA me-lag for power voltage < 50 Vac/dc
ABC
Common
Vexc.
4/20 mA
ABC
NC
Com.
NO
Opon S1 (Modbus RTU)
ABC
Common
B
A
Opon 2 Opon 1
12345 890
-Vdc / Neutral
+Vdc / Phase
Not Connected
ABC
Opon A2 (relay)
NC
Com.
NO
G IH
G IH
~Vac, ±Vdc, resistance, mA, pot
thermocouple+, Pt+, Ni+, PTC+, NTC+
~600 Vac, ~200 Vac
±600 Vdc, ±200 Vdc
~5 Aac, ±5 Adc
neutral, 0 V, common
Vexc, Pt100 3 wires, pot+
external control
NTC probes ‘R25’
(congurable)*
Jumpers
‘S’
Jumper
‘T’
Range
of measure
Accuracy
(% of reading)
Beta
(congurable)
10K F K 4-5 -60ºC to
150ºC
<1.5 % of
reading
3500
*‘Beta’ congurable (2000 to 5500). R25 congurable. Resistance measure from 100R to 1MR.
AC ranges Scalable Jumpers
‘S’
Jumper
‘T’
Accuracy
(% FS)
~ 600 Vac
from 9999
to -1999
G I
4-5
<0.30 %
(up to 150 Hz)
~ 200 Vac I
~ 20 Vac A I
~ 2 Vac B I
~ 200 mVac C I
~ 60 mVac E I
~ 5 Aac I <0.50 %
(up to 150 Hz)
~ 20 mAac D I
DC ranges Scalable Jumpers
‘S’
Jumper
‘T’
Accuracy
(% FS)
±600 Vdc
from 9999
to -1999
G
4-5
<0.20 %
±200 Vdc ---
±20 Vdc A
±2 Vdc B
±200 mVdc C
±60 mVdc E <0.25 %
±5 Adc - - -
±20 mAdc D<0.15 %
PTC probes
Family
Jumpers
‘S’
Jumper
‘T’
Range in ºC
(in ºF)
Total error
KTY-121 F
4-5 -55 / 150 ºC
(-67 / 302 ºF) <1 º
KTY-210 F H K
KTY-220 F H K
Pt and Ni
probes
Jumpers
‘S’
Jumper
‘T’
Range in ºC
(in ºF)
Total
error
Current at
sensor
Pt100
(3 wires) F H J 5-6 -200 / 700 ºC
(-328 / 1292 ºF)
<1º
< 900 uA
Pt100
(2 wires) F H
4-5
-200 / 700 ºC
(-328 / 1292 ºF) < 900 uA
Pt500 F -150 / 630 ºC
(-238 / 1166 ºF) < 90 uA
Pt1000 F -190 / 630 ºC
(-310 / 1166 ºF) < 90 uA
Ni100 F H -60 / 180 ºC
(-76 / 356 ºF) < 900 uA
Ni200 F H -60 / 120 ºC
(-76 / 248 ºF) < 900 uA
Ni1000 F -60 / 180 ºC
(-76 / 356 ºF) < 90 uA
Thermocouples
Jumpers
‘S’
Jumper
‘T’
Range in ºC
(in ºF)
Total error
(
cold juncon included
)
tc. K
E
4-5
-100 / 1350 ºC
(-148 / 2462 ºF)
<3 º 
tc. J -100 / 1200 ºC
(-148 / 2192 ºF)
tc. E -100 / 1000 ºC
(-148 / 1832 ºF)
tc. N -100 / 1300 ºC
(-148 / 2372 ºF)
tc. L -100 / 900 ºC
(-148 / 1652 ºF)
tc. R
E J
0 / 1768 ºC
(32 / 3214 ºF)
tc. S 0 / 1768 ºC
(32 / 3214 ºF)
tc. T -100 / 400 ºC
(-148 / 752 ºF)
tc. C E0 / 2300 ºC
(32 / 4172 ºF)
<5 º
tc. B E J 700 / 1820 ºC
(1292 / 3308 ºF)
Resistance
ranges
Scalable Jumpers
‘S’
Jumper
‘T’
Accuracy
(% reading)
0 to 5 K from 9999
to -1999
F H K
4-5
<1.5 % of
reading
0 to50 K F K
Process
signals
Scalable Jumpers
‘S’
Jumper
‘T’
Accuracy
(% FS)
4/20 mA from 9999
to -1999
D1-2*<0.15 %
0/10 Vdc A <0.20 %
* Place jumper ‘T’ at posion 1-2 for +15 Vdc excitaon voltage at terminal 5. Oponally,
place jumper ‘T’ at posion 4-5 to work with ‘external contact’ at terminal 5.
Potenometers
nominal value
Scalable Jumpers
‘S’
Jumper
‘T’
Accuracy
(% FS)
500 R to 20 K from 9999
to -1999 A 2-3
<0.5 %
!
(acve output A-B)
(passive output B-C)
Risk of electric shock. Removing the front cover will grant access to internal
circuits which may be at dangerous voltage. Disconnect the input signal and
the power supply to prevent electric shock to the operator. Operaon must be
performed by qualied personnel only.
Use a at screwdriver to unlock clips ‘D’, C’, ‘B’
and ‘A’, in this order. Remove the front lter.
Gently let the internal boards slide out of the
instrument.
To reinsert the boards in the housing :
1. make sure that the boards are correctly con-
nected to the displays pins
2. slide the boards into the housing guides
3. place the front lter at corner X, and then
insert clips ‘A’, ‘B’, ‘C’ and ‘D’ in this order. XA
C
BD
Internal Jumpers
Opt.1
Opt.2
Opt.1
Display module Oponal modules
Housing
Front lter
Input signal terminal
Jumpers ‘S’
for signal range selecon
Displays
F
E
G
H
I
J
D
B
C
A
K
Jumpers not used can be
stored in the following three
‘no contact’ posions.
F
E
G
H
I
J
D
B
C
A
K
6
5
4
3
2
1
Jumper ‘T’
for terminal 5 funcon selecon
DP20 shown smaller
than actual size
Quick installaon guide DP20 (page 1/2) www.omega.com/ DP20.html
Detail of the female
terminal provided.
96 mm
48 mm
91 mm
(including terminal)
16
8
75
(0.63)
(0.31)
(2.95)
Panel
cut-out
92
(3.63)
44
(1.74)
(3.78)
(1.89)
(3.58)
TM
Frequency Scalable Jumpers ‘S’ Jumpers ‘T’ Accuracy
(% of reading)
15 Hz to 100 Hz from 9999
to -1999
select Vac or
Aac range
4-5 <0.15%
of reading
10. Regulaons
This instrument conforms to the actual CE regulaons. For a copy of the ‘CE declaraon
of conformity’ see secon 3. Applicable regulaons are :
Security regulaons EN-61010-1 (‘Fixed’ equipment, ‘Permanently connected’.
‘Double’ isolaon. ‘CAT-II’ category)
Electromagnec compability regulaons EN-61326-1
According to direcve 2012/19/EU, electronic equipment must be re-
cycled in a selecve and controlled way at the end of its useful life.
This instrument does not provide a general mains switch and will start operaon as
son as power is connected. The instrument does not provide protecon fuse, and the
fuse must be added during installaon.
Risk of electrical shock. Instrument terminals can be connected to
dangerous voltage.
Instrument protected with double isolaon. No earth connecon
required.
Instrument conforms to CE rules and regulaons.
Range, scaling and decimal point 0/600 Vac = 0/600
Alarm 1 as maximum
Setpoint 1000
Hysteresis 0 counts
Alarm 2 as maximum
Setpoint 1000
Hysteresis 0 counts
External control o
Fast access all o
Tools
Opon 1 o (retains last conguraon value)
Step 1
Average 0
Manual oset 0
Second scaling 0/600
‘Eco’ mode o
Temperature resoluon 1º
Degrees ºC
Alpha 385
cJc on
AC ‘deadband’ 20
Luminosity 3
Password o
Opon
Analog output 0/100.0=4/20 mA
Serial Modbus RTU 9600 bps, address 1, format 8n1
Jumpers ‘S’ range for 600 Vac
Jumper ‘T’ external contact ‘EK’ funcon
11. Factory conguraon
9. Conguraon menu
Press ‘SQ’ (<) for 1 second to access
the ‘Conguraon menu’.
Input AC signals
600 V
200 Vac
20 Vac
2 Vac
200 mVac
60 mVac
5 Aac
20 mAac
DC signals
±600 Vdc
±200 Vdc
±20 Vdc
±2 Vdc
±200 mVdc
±60 mVdc
±5 Adc
±20 mAdc
Process
4/20 mA
0/10 Vdc
Thermocouples
thermocouple
K
thermocouple
J
thermocouple
E
thermocouple
N
thermocouple
L
thermocouple
R
thermocouple
S
thermocouple
B
thermocouple
T
thermocouple
C
NTC probes
Resistances
0 to 5 K
0 to 50 K
Alarm 1
Setpoint
Hysteresis
Type
Alarm 2
Setpoint
Hysteresis
Type
Temp.
resoluon.
1º resoluon
0.1º resoluon
Scaling 2 Decimal
Display Low
Display High
‘Eco’ mode 5 to 255 sec.
Filter 0 a 100
Steps
Oset
Decimal 1
Decimal 2
Decimal 0
Scaling 2
Decimal 3
Opon 1
analog
relay
NoneTools
Modbus RTU
enters the
analog output
calibration
menu
Scaling Decimal
Display Low
Display High
Key UP
Maximum
Minimum
Setpoint 1
Setpoint 2
Minimum
Hold
Maximum
External
control
Disabled
Alpha
Alpha 385
Alpha 390
Front keypad menu operaon
Key SQ (<) - 1. Press to access the ‘Conguraon menu’.
2. Press to enter into the actual menu entry.
3. Press to accept a value.
Key UP (5) - 1. Press to access the ‘Fast access’ menu.
2. Press to move through available menu opons.
3. Press to increase the value of a numerical parameter.
Key LE (3) - 1. Without funcon.
2. Press to return to a previous level of the menu, discarding changes (to
validate changes, use SQ (<)).
3. Move through the digits of a numerical parameter.
To save the conguraon changes, press key LE (3) unl exing the menu (shown by
ashing decimal points). Instrument shows the signal range selected and starts opera-
on with the new conguraon.
PTC probes
KTY 121
KTY 210 and 220
Minimum
Brightness
Maximum
Standard
Password
Version
Factory reset
‘AC deadband’
‘Deadband’ on AC
ranges. Value 0 to 100.
Opon 1
conguraon
Analog Display Low
Display High
Modbus RTU Address
Speed
1 to 247
9600 bps
4800 bps
Format
Cold juncon Thermocouple cold juncon
compensaon ‘on’ or ‘o’
Degrees
Celsius
Fahrenheit
RTD probes
Pt100
(2 wires)
Pt500
Pt1000
Ni100
Ni200
Ni1000
Pt100
(3 wires)
Potenometer
If you need addional informaon, see secon 3 to download
the full User’s Manual.
12. User’s manual !
www.omega.com/ DP20.html
600U
600U
tArE
Tare funcon
Frequency
FrEq
Note: The AC powered units cannot be shipped to Canada.

Other manuals for DP20

1

Other Omega Touch Panel manuals

Omega TX82B User manual

Omega

Omega TX82B User manual

Omega DP400TP User manual

Omega

Omega DP400TP User manual

Omega DP400TP User manual

Omega

Omega DP400TP User manual

Omega DP41-S User manual

Omega

Omega DP41-S User manual

Omega DP41-TC Operating and maintenance instructions

Omega

Omega DP41-TC Operating and maintenance instructions

Omega DP41-E User manual

Omega

Omega DP41-E User manual

Omega DFG-RS3 User manual

Omega

Omega DFG-RS3 User manual

Omega DP41-S User manual

Omega

Omega DP41-S User manual

Popular Touch Panel manuals by other brands

Beijer Electronics X2 pro Hardware and installation guide

Beijer Electronics

Beijer Electronics X2 pro Hardware and installation guide

Cincoze CO-100/P1001 Series user manual

Cincoze

Cincoze CO-100/P1001 Series user manual

Xinje XP3-16R manual

Xinje

Xinje XP3-16R manual

ero electronic LHI R Addendum

ero electronic

ero electronic LHI R Addendum

YASKAWA VIPA HMI TP 608C manual

YASKAWA

YASKAWA VIPA HMI TP 608C manual

Avalue Technology RPC-0801-910 Quick reference guide

Avalue Technology

Avalue Technology RPC-0801-910 Quick reference guide

Icop PPC-150-D2 Series user manual

Icop

Icop PPC-150-D2 Series user manual

AMX AXM-CP Dimensional drawing

AMX

AMX AXM-CP Dimensional drawing

GETT InduSmart Panel-PC GreenLine 10,1 operating instructions

GETT

GETT InduSmart Panel-PC GreenLine 10,1 operating instructions

Rotronic HygroPalm AW1 instruction manual

Rotronic

Rotronic HygroPalm AW1 instruction manual

Siemens TP27 Equipment manual

Siemens

Siemens TP27 Equipment manual

weintek cMT-iPC15 Installation instruction

weintek

weintek cMT-iPC15 Installation instruction

Boser BPC-6690 manual

Boser

Boser BPC-6690 manual

Carrier Evergreen 19XR Installation and start-up instructions

Carrier

Carrier Evergreen 19XR Installation and start-up instructions

Smartbox Touch Pad manual

Smartbox

Smartbox Touch Pad manual

Orion OLS-3201PGB user guide

Orion

Orion OLS-3201PGB user guide

Siemens SIMATIC HMI TP1200 Comfort quick start guide

Siemens

Siemens SIMATIC HMI TP1200 Comfort quick start guide

Avalue Technology RITY122 Quick reference guide

Avalue Technology

Avalue Technology RITY122 Quick reference guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.