manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Omnitec
  6. •
  7. Water Filtration System
  8. •
  9. Omnitec OWF115 User manual

Omnitec OWF115 User manual

Other Omnitec Water Filtration System manuals

Omnitec OmniAire 1000 Series User manual

Omnitec

Omnitec OmniAire 1000 Series User manual

Omnitec OmniAire 18000 User manual

Omnitec

Omnitec OmniAire 18000 User manual

Omnitec OmniFlow User manual

Omnitec

Omnitec OmniFlow User manual

Popular Water Filtration System manuals by other brands

Atlantic Ultraviolet Mighty Pure MP16A owner's manual

Atlantic Ultraviolet

Atlantic Ultraviolet Mighty Pure MP16A owner's manual

SunSun CBG-500 Operation manual

SunSun

SunSun CBG-500 Operation manual

Hayward XStream Filtration Series owner's manual

Hayward

Hayward XStream Filtration Series owner's manual

Contech DownSpout StormFilter Operation and maintenance

Contech

Contech DownSpout StormFilter Operation and maintenance

Teka Airfilter MINI operating instructions

Teka

Teka Airfilter MINI operating instructions

Wisy LineAir 100 Installation and operating instructions

Wisy

Wisy LineAir 100 Installation and operating instructions

Schaffner Ecosine FN3446 Series User and installation manual

Schaffner

Schaffner Ecosine FN3446 Series User and installation manual

Pentair FLECK 4600 SXT Installer manual

Pentair

Pentair FLECK 4600 SXT Installer manual

H2O International H20-500 product manual

H2O International

H2O International H20-500 product manual

Renkforce 2306241 operating instructions

Renkforce

Renkforce 2306241 operating instructions

Neo-Pure TL3-A502 manual

Neo-Pure

Neo-Pure TL3-A502 manual

STA-RITE VERTICAL GRID DE FILTERS S7D75 owner's manual

STA-RITE

STA-RITE VERTICAL GRID DE FILTERS S7D75 owner's manual

Applied Membranes W-G844EM Operation and maintenance manual

Applied Membranes

Applied Membranes W-G844EM Operation and maintenance manual

BEGA 116 Instructions for use

BEGA

BEGA 116 Instructions for use

WATA Standard operating instructions

WATA

WATA Standard operating instructions

Price FFU series Installation and service manual

Price

Price FFU series Installation and service manual

Gaggenau BRITA INTENZA 467873 manual

Gaggenau

Gaggenau BRITA INTENZA 467873 manual

Brita SAFF-100 user guide

Brita

Brita SAFF-100 user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Maintenance:
The WFS will require frequent cleaning of the inlet mesh
screen and periodic filter replacement. Watch for the follow-
ing indications of required service caused by plugged screen
or filters:
- Reduced water flow
- Pump is surging and straining
- Pump shuts down when filters are loaded and discharge
pressure reaches 45 psi
Troubleshooting
Pump will not start
- Check power is ON
- Check the circuit breaker on the WFS unit is not tripped
- Check that GFCI on WFS unit is not tripped
- Correct voltage 115 VAC (+/- 10%)
- Check if pump is hot - thermo protection shuts down motor
at 230° F and restarts automatically when cooled down
- Check that outlet hose is not kinked
Pump will not prime
- Out of water supply
- Inlet screen is plugged - Clean inlet screen; operation with-
out this screen is not recommended
- Check for a large amount of sediment in filter housing.
Replace the 20 and 5 micron filters if required
- Suction hose has a serious vacuum leak
- Inlet or outlet hose has a sharp kink
- Pumping housing is cracked
4640 Campus Place #110 - Mukilteo, WA 98275
www.omnitecdesign.com
Water Filtration
Model OWF115
This commercial and industrial water filtration system is
designed for purification of waste water from portable
showers and similar sources at construction sites.
Omnitec Design, Inc.
4640 Campus Place #110 - Mukilteo, WA 98275
www.omnitecdesign.com
SPECIFICATIONS
Power: 115 VAC, 1 amp
Controls: ON/OFF Switch; 1 amp Circuit Breaker; GFCI
First Filter: 20 micron, 9¾” x 2¾”
Final Filter: 5 micron, 9¾” x 2¾”
Housing: Aluminum 0.080”, mill finish, size 15”H x 8”W x
23”L
Weight: 25 lbs.
ORDERING INFO............................... PART #
Water Filtration System 115 VAC................................. OWF115
Filter, 20 micron, (Qty 2) ............................................. OWF20
Filter, 5 micron, (Qty 2)................................................ OWF5
The Omnitec Design Water Filtration System is a self priming,
positive displacement pump with up to 9 feet vertical lift. The
unit has a #50 mesh screen on the inlet side with 20 and 5
micron filters downstream of the pump to remove fine
suspended impurities. When properly used, the OWF System
can be used for intermittent or continuous service.
CAUTION - Pump Limitations
DO NOT USE TO PUMP FLAMMABLE LIQUIDS
NEVER OPERATE THE PUMP IN AN EXPLOSIVE
ENVIRONMENT
DO NOT ASSUME FLUID COMPATIBILITY
DO NOT ADJUST PRESSURE SWITCHES WITHOUT
CONSULTING WITH PUMP MANUFACTURER
DO NOT USE PUMP WITH FLUIDS AT
TEMPERATURES HIGHER THAN 130° F
OPERATING INSTRUCTIONS
Unpacking: Check unit for damage.
Operation: Place the Water Filtration System (WFS) close
to the waste water source on a level, dry surface standing up-
right. WFS pump is self priming and the discharge pressure is
factory set at 45 psi.
To start the machine:
1. Connect the suction hose (garden hose thread) from the
waste water source to WFS inlet connection, and from WFS
outlet to drain. Make sure the hose is not kinked or damaged.
2. Connect power cord to 115VAC grounded circuit. Keep the
cord out of water and do not route it under the unit.
3. Turn unit ON and wait for the pump to prime the system.
Check that the water is discharging from the unit.
Note: New filters take longer to fill with water.
4. When the water source is depleted, turn the pump OFF.
The pump can operate dry without damage, but it is better to
shut it down.