iConverter
iConverter®4Tx
4-Port 10/100BASE-TX Managed Ethernet Switch
iConverter
TheiConverter 4Tx10/100EthernetSwitchmoduleisamember
ofthe managed iConverter productfamily. The4Tx provides a
compact 4-Port 10/100 Ethernet switch that is expandable
across the iConverter 19-Module, 5-Module and 2-Module
chassis backplanes, as well as being supported as a
standalone switch with the iConverter 1-Module Chassis.
The iConverter 4Tx UTP ports feature 10/100Mbps, Half or
Full-Duplex and auto-negotiation with both hardware and
software controls. Hardware control is available for two ports
whileallfour portsare undersoftware controlfor thesefeatures.
RJ-45crossover support eliminatesneed for acrossover cable
and facilitates connectivity to different types of network
equipment. The 4Tx crossover switch is supported on Port 1.
Ports 2, 3 and 4 support an automatic crossover detection
mode. The 4Tx also features two Ethernet backplane ports to
provideconnectivityto adjacentmodules fornetwork expansion
and for in-band connectivity to an iConverter Network
ManagementModule.
4Tx enhanced features include Port VLAN which allows
complete control of traffic flow between a module’s ports, and
PortAccess Control which incorporates remote enabling and
disablingof each individual port.The4Tx supports reporting of
MIBstatisticsthatareavailablefor32variablesperport,reporting
a wide range of real-time packet statistics to provide
performanceand operationalmonitoring.
iConverter 4Txmodulesarehot-swappableandcanbemounted
ina19-Module (2Uhigh) or5-Module (1Uhigh) rack-mountable
chassis(19-inch or23-inch)with anycombinationof redundant
AC,24VDCor48VDCpowersupplies.Theycanalsobemounted
in a 2-Module AC or 18 to 60VDC powered chassis, or in a
1-ModuleAC/DCpowered chassis.
The iConverter 4TxManaged Ethernet Switch supports
10BASE-Tor 100BASE-TX on fourUTP ports
Enhanced features include Port VLAN, Port Access
Control and MIB Statistics
Multiple 4Tx modules can be installed to expand the
port concentration in a single chassis
SupportsHalf or Full-Duplex andauto-negotiation
RJ-45crossover support eliminates needfor
differentcables in connecting to various devices
Ethernet backplane ports for connectivity to adjacent
modules
Management is available with the addition of a
management module to the chassis
SNMPmanagement via NetOutlook™providesreal-time
port and module information, remote parameter
configurationand trap notification
Conformsto IEEE 802.3, 10BASE-T and 100BASE-TX
specifications
Modules are hot-swappable in 19-Module, 5-Module,
2-Moduleor 1-Module chassis
LifetimeWarranty and free 24/7TechnicalSupport
800-675-8410 • 949-250-6510 • www.omnitron-systems.com • [email protected] • 140 Technology Dr. • Irvine, CA 92618
Trademarksareowned bytheir respectivecompanies. iConverterisa registeredtrademark ofOmnitron SystemsTechnology,Inc.
NetOutlook isa trademarkof OmnitronSystemsTechnology,Inc. Specificationssubject tochange withoutnotice.
©2003-2007Omnitron SystemsTechnology,Inc. All rightsreserved.
091-18480-004E 9/07
Managementisaccomplished byusing aNetworkManagement
Module (NMM) or a media converter with integrated management
(such as an iConverter 10/100M2) that provides monitoring,
remote configuration and trap notification. The management
modulecan beaccessed via SNMP,Telnetandviaa serialport.
TheSNMP-basedmanagement isaccomplishedvia Omnitron’s
intuitive,graphic-oriented NetOutlook management software or
third party SNMP management software, while the Telnet and
theserialinterfaceshave aneasy-to-use,menu-driveninterface.
Some of the real-time 4Tx parameters that can be monitored
include link and data receive status. Other parameters include
moduletypeand model,hardware andsoftwarerevisions, serial
numbersandauser-defined identifier.
Theusercan overridethe 4Txmodule’s physicalswitch settings
byusingSNMPorTelnet toremotelyconfigure switch-selectable
parameters such as auto-negotiation, Half or Full-Duplex and
BackplaneSelection.
InadditiontoallstandardiConverter SNMPtrapssuchasmodule
insertion and removal, the 4Tx modules can generate traps on
port state changes including link-up and link-down. Trap
monitoring of specific events can be selectively enabled or
disabledby the network administrator.
Configuration 19-Module 5-Module 2-Module 1-Module
AC 24VDC 48VDC AC 24VDC 48VDC AC 18-60
VDC US AC Universal
AC
One (1) Power Supply 8200-1 8206-1 8205-1 8220-1 8226-1 8225-1 8230-0 8235-0 8240-1 8240-2
One (1) Power Supply
w/ Dying Gasp Support -- -- -- -- -- -- 8230-1 8235-1 8241-1 8241-2
Two (2) Power Supplies 8200-2 8206-2 8205-2 8220-2 8226-2 8225-2 -- -- 8245-111* 8245-112*
Three (3) Power Supplies 8200-3 8206-3 8205-3 -- -- -- -- -- -- --
Spare Power Supply 8200-9 8206-9 8205-9 8220-9 8226-9 8225-9 -- -- -- --
23" Rack Mounting Kit 8091-2 8091-2 8091-2 8092-2 8092-2 8092-2 -- -- -- --
Blank Module Panel 8090-0 8090-0 8090-0 8090-0 8090-0 8090-0 8090-0 8090-0 -- --
Wall-Mounting Hardware Kit -- -- -- -- -- -- 8249-0 8249-0 8249-0 8249-0
DIN-Rail Mounting Kit -- -- -- -- -- -- -- -- 8250-0 8250-0
*Please refer to the iConverter 1-Module Redundant Power Chassis data sheet for additional model numbers and ordering options.
For wide (-40 to +60º C) and extended (-40 to +75º C) temperature range chassis, contact Omnitron for details.
Model Type 4Tx
Protocols 10BASE-T, 100BASE-TX
UTP Connectors RJ-45
Controls UTP X-over (Port 1), BP Enable,
Auto/Man, 10/100, FDX/HDX
LED Displays Power, 10/100 UTP Link
Dimensions W:0.85" x D:4.5" x H:2.8"
Weight 8 oz.
Compliance UL, CE, FCC Class A
Power Requirement 0.9 @ 3.3VDC (typical)
Temperature Standard: 0 to 50º C
Wide: -40 to 60ºC
Storage: -40 to 80º C
Humidity 5 to 95% (non-condensing)
Altitude -100m to 4000m
MTBF (hrs) 910, 000
Model Type Connectors Distance
8480-4 RJ-45 x 4 100m
For wide temperature (-40 to 60º C) modules, add a "W" to the end of
the model number. Consult factory for other configurations and
extended temperature (-40 to +75ºC) modules.

Other Omnitron Systems Technology Switch manuals

Omnitron Systems Technology OmniConverter 10GPoE+/Sx User manual

Omnitron Systems Technology

Omnitron Systems Technology OmniConverter 10GPoE+/Sx User manual

Omnitron Systems Technology FlexSwitch 6540-FK User manual

Omnitron Systems Technology

Omnitron Systems Technology FlexSwitch 6540-FK User manual

Omnitron Systems Technology RuggedNet GPoE+/Si User manual

Omnitron Systems Technology

Omnitron Systems Technology RuggedNet GPoE+/Si User manual

Omnitron Systems Technology 1Fx+4U User manual

Omnitron Systems Technology

Omnitron Systems Technology 1Fx+4U User manual

Omnitron Systems Technology FlexSwitchTM 8U 6700-FK User manual

Omnitron Systems Technology

Omnitron Systems Technology FlexSwitchTM 8U 6700-FK User manual

Omnitron Systems Technology OmniConverter 10GPoEBT/M User manual

Omnitron Systems Technology

Omnitron Systems Technology OmniConverter 10GPoEBT/M User manual

Omnitron Systems Technology OmniConverter 10GPoE+/M User manual

Omnitron Systems Technology

Omnitron Systems Technology OmniConverter 10GPoE+/M User manual

Omnitron Systems Technology OmniConverter GPoE+/SX User manual

Omnitron Systems Technology

Omnitron Systems Technology OmniConverter GPoE+/SX User manual

Omnitron Systems Technology FlexCenter 10 User manual

Omnitron Systems Technology

Omnitron Systems Technology FlexCenter 10 User manual

Omnitron Systems Technology iConverter 8481-4 User manual

Omnitron Systems Technology

Omnitron Systems Technology iConverter 8481-4 User manual

Omnitron Systems Technology RuggedNet GPoE+/Mi User manual

Omnitron Systems Technology

Omnitron Systems Technology RuggedNet GPoE+/Mi User manual

Omnitron Systems Technology iConverter GX/X User manual

Omnitron Systems Technology

Omnitron Systems Technology iConverter GX/X User manual

Omnitron Systems Technology RuggedNet 10GPoE+/Si User manual

Omnitron Systems Technology

Omnitron Systems Technology RuggedNet 10GPoE+/Si User manual

Popular Switch manuals by other brands

SMC Networks SMC6224M Technical specifications

SMC Networks

SMC Networks SMC6224M Technical specifications

Aeotec ZWA003-S operating manual

Aeotec

Aeotec ZWA003-S operating manual

TRENDnet TK-209i Quick installation guide

TRENDnet

TRENDnet TK-209i Quick installation guide

Planet FGSW-2022VHP user manual

Planet

Planet FGSW-2022VHP user manual

Avocent AutoView 2000  AV2000BC AV2000BC Installer/user guide

Avocent

Avocent AutoView 2000 AV2000BC AV2000BC Installer/user guide

Moxa Technologies PT-7728 Series user manual

Moxa Technologies

Moxa Technologies PT-7728 Series user manual

Intos Electronic inLine 35392I operating instructions

Intos Electronic

Intos Electronic inLine 35392I operating instructions

Cisco Catalyst 3560-X-24T Technical specifications

Cisco

Cisco Catalyst 3560-X-24T Technical specifications

Asante IntraCore IC3648 Specifications

Asante

Asante IntraCore IC3648 Specifications

Siemens SIRIUS 3SE7310-1AE Series Original operating instructions

Siemens

Siemens SIRIUS 3SE7310-1AE Series Original operating instructions

Edge-Core DCS520 quick start guide

Edge-Core

Edge-Core DCS520 quick start guide

RGBLE S00203 user manual

RGBLE

RGBLE S00203 user manual

Thrustmaster FLIGHT SIMULATOR X quick guide

Thrustmaster

Thrustmaster FLIGHT SIMULATOR X quick guide

Southwire SURGE GUARD 41390 RVC troubleshooting guide

Southwire

Southwire SURGE GUARD 41390 RVC troubleshooting guide

Buhler Nivotemp NT 61 Brief instructions

Buhler

Buhler Nivotemp NT 61 Brief instructions

Kramer VS-41HDCP user manual

Kramer

Kramer VS-41HDCP user manual

Techly IDATA AU-270 user manual

Techly

Techly IDATA AU-270 user manual

Belkin F1U109 user manual

Belkin

Belkin F1U109 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.