Windows Vista, Windows 7)
Max. program size 1024steps (The internal storage capacity of the inverter is 1024 steps or 6 Kilobytes.)
Programming support
function (programming
software)
-Editing (on Windows) / - Display (on Windows)
-Program syntax check (on Windows)
-Downloading, uploading, and full clearance of program
Execution format Execution by interpreter in an execution cycle of 2ms per instruction (possible subroutine call with
nesting in up to 8 layers)
Input/output-related functions
External input
Contact Signal 24v open – collector input (using intelligent input terminals)
Program run signal input RX: Assign to the PRG terminal / Always run
MX2: Assign to the PRG terminal / Always run
Multifunction terminals RX: Up to 8 terminals (X(00) to X(07))
MX2: Up to 8 terminals (X(00) to X(07))
General-purpose analog input XA(0): 0 to 10V (O terminal)
XA(1): 4 to 20mA (OI terminal)
XA(2): 0 to 10V (O2 terminal) (Only RX)
External Output
General-purpose output terminal RX: Up to 6 terminals (Y(00) to Y(05))
MX2: Up to 3 terminals (Y(00) to Y(02))
General-purpose analog output YA (0): Assignable to the
terminal (FM terminal for RX)
YA (1): Assignable to the AM terminal
YA (2): Assignable to the AMI terminal (Only RX)
Reserved Words
Instructions
(1) Program control instructions
-Loop (For) / - Unconditional branching (Goto) / -Time control (Wait)
-Conditional branching (If Then, Ifs Then Else, Select Case, Until, and While)
-Subroutine (call, sub) / - Others (Entry, End, Sub, End Sub, Inc, and Dec)
(2) Arithmetic instructions
-Arithmetic operation (+,-,*,/) / - Remainder (Mod) / -Substitution (=)
-Absolute value (Abs) / - Logic operation (Or, And, Xor, and Not)
(3) Input/Output control
-General-purpose input/output (bit input, word input, bit output, and word output)
- Reading of inverter input terminal.
(4) Timer control: - Delay operation / -Timer control
(5) Parameter control: - Rewriting of parameters by reselecting code on the operator’s display
Number of variables
User-defined variable U (00) to U (31) (32 variables)
Internal user variable UL (00) to UL (07) (8 variables)
Set frequency SET-Freq
Acceleration time ACCEL
Deceleration time DECEL
Monitoring variable FM, Iout, Dir, PID-FB, F-CNV, Tmon, Vout, Power, RUN-Time, ON-
Time, PlsCnt (Only RX), POS, STATUS, DCV, ERR CNT, ERR(1),
ERR(2), ERR(3), ERR(4), ERR(5), and ERR(6)
Bit commands
FW, RV, CF1, CF2,CF3,CF4,JG,DB,SET,TCH,FRS,EXT,USP,CS,SFT,
AT, RS, STA, STP, F/R, PID, PIDC, UP, DWN, UDC, OPE, SF1, SF2,
SF3, SF4, SF5, SF6, SF7, OLR, TL, TRQ1-2, BOK, LAC, PCLR, ADD,
F-TM, ATR, KHC, AHD, CP1-3, ORL, ORG, SPD, RS485, HLD, ROK,
DISP.
Output Functions
RUN, FA1, FA2, OL, OD, AL, FA3, OTQ, UV, TRQ, RNT, ONT, THM,
BRK, BER, ZS, DSE, POK, FA4, FA5, OL2, ODc, OIDc, FBV, NDc,
LOG1, LOG2, LOG3, WAC, WAF, FR, OHF, LOC, IRDY, FWR, RVR,
MJA, WCO, WCOI, FREF, REF, SETM, EDM.
General-purpose input
contact
LX : X(00) to X(06) (7 contacts)
RX : X (00) to X (07) (8 contacts)
MX2 : X(00) to X(07) (8 contacts)
Extended IO option input
contact
LX : X(07) to X(11) (3G3AX-EIO-E expansion card)
RX : -----
MX2 : -----
General-purpose output
contact
LX : Y(00) to Y(03) (4 contacts)
RX :Y(00) to Y(05) (6 contacts)
MX2 : Y(00) to Y(02) (3 contacts)
Extended output contact LX: Y(04) to Y(06) (3G3AX-EIO-E expansion card)