9
V600V600
■IDSC Series
Note Refer to the applicable ID Controller Operation Manual for details.
■ID Sensor Units
Note The C500-IDA02 must be used with the C500-IDS02-V1. The cable can be extended to a maximum of 200 m.
Item IDSC Series
IDSC-CIDR-A
IDSC-CIDT-A
Host interface RS-232C
Possible number of R/W Heads 1
Power supply voltage 100 to 240 VAC, 50/60 Hz
Acceptable power supply voltage 85 to 264 VAC
Power consumption 60 VA max.
Insulation resistance 20 M
W
min. (at 500 VDC) between power terminals and case, between I/O terminals and case,
or between the power supply terminals and I/O terminals
Dielectric strength 2,300 VAC, 50/60 Hz for 1 min between the points listed above;
Leakage current: 10 mA max.
Noise immunity 1,500 V (p-p) pulses of 100 ns to 1 µs pulse width with a 1 ns rise time
Vibration resistance 10 to 57 Hz, 0.075-mm double amplitude, 57 to 150 Hz, 9.8 m/s2acceleration for 80 min each
in X, Y, and Z directions
Shock resistance 150 m/s23 times each in X, Y, and Z directions
Ambient temperature Operating: 0
to 55
C
Storage:
-
20
to 75
C (excluding the battery pack)
Ambient humidity 10% to 90% (with no condensation)
Operating conditions No corrosive gases
Memory back–up The battery life is 5 years regardless of whether an RTC is provided.
The period that data is retained after a power interruption depends on the ambient temperature.
Replace the battery within one week of the battery low indicator flashing.
Diagnostic functions Checks for CPU errors, memory errors, power interruptions, and transmission errors
Ground Ground to 100
W
or less.
Construction For inter-panel installation
Weight Approx. 1,500 g
Item C500-IDS01-V2 (for general use)
C500-IDS02-V1 (for long-distance
transmission)
(See note)
C200H-IDS01-V1
Communications control Dedicated time sharing
Possible number of R/W Heads 1 R/W Head
DC memory format 8–bit dedicated format
Commands The following 7 commands are used: Read, Write, Auto read, Auto write, Abort, Cancel auto–com-
mand, Data management processing
Transmission capacity Up to 502 bytes (251 words) of data can be
batch–transferred using the Intelligent I/O in-
structions (READ/WRITE)
Up to 1024 bytes (512 words) of data can be
transferred (at 20 words/PLC cycle)
Diagnostic functions 1. CPU watchdog timer
2. Detects transmission error with DC, absence of DC
3. Error log function, records transmission errors (with capacitor back-up)
Monitoring functions A Handheld Programming Console (with a special keysheet) can be used to monitor operation
(max. cable length: 4 m). The following operations are possible: Read 1-byte, Write 1-byte, Contin-
uous write, Test, and Monitor error log
Memory back-up The error information has a capacitor back-up. Data retained at least 15 days (at 25
C).
I/O word allocation Two words are allocated when the Intelligent I/O
instructions (READ/WRITE) are used
Four words are allocated when the Intelligent I/O
instructions (READ/WRITE) are not used (se-
lectable)
Five words are allocated within the Special I/O
(IR) area (IR 100 to IR 199)
External power supply 250 mA min. at 24 VDC ---
Internal current consumption 400 mA max. at 5 VDC 250 mA max. at 5 VDC
120 mA max. at 26 VDC
(to drive the R/W Head) (see note)
Weight 700 g max. 400 g max.