ONLEVEL Banana Slide 50 User manual

MA: DS032009-OnLevel/07.2021
Montageanleitung
Installation instructions
Banana Slide 50
für Glastüren bis 50 kg
mit Einzugsdämpfung
einflügelig (mit Berechnungen)
Glasstärken
von 8 und 10 mm ESG
Banana Slide 50
for glass doors up to 50 kg
with damper
single leaf (with calculations)
Glass thicknesses
from 8 and 10 mm TSG

SW 8
AF 8
Größe 2 / 2,5 / 3
Size 2 / 2,5 / 3
Größe 3 - 4 Nm
Size 3 - 4 Nm
Technical information
• suitable for tempered safety glass (TSG)
• maximum leaf weight 50 kg
• glass thicknesses 8 and 10 mm
• minimum leaf width for use of the door
damper 700 mm
• with fixed glazing: ceiling installation
• without fixed glazing: ceiling- and wall installation
• all dimensions in millimeter
• the relation of the door height to the door width
may not cross 2,5:1
Important information
Glass panels with self-cleaning coating cannot be used
with this fitting.
The glass panel must be clean and free of grease in the
area of the clamping areas when installing the trolleys
and, if applicable, the release bolts for the door damper.
Therefore, clean the glass panel in this area, e.g. with
special cleaner or acetone. We also recommend cleaning
the clamping surfaces in the trollys and the release bolt.
For all installations where the glass door closes up to a
wall or a second glass panel, additional glass edge
protection should be installed.
Safety distances (at least 25 mm) between door handle/
flush pull and door/closing edge, must be maintained
according to DGUV guideline.
Benötigtes Werkzeug
Required tools
Technische Informationen
• für Einscheibensicherheitsglas (ESG) geeignet
• maximales Flügelgewicht 50 kg
• Glasdicken von 8 und 10 mm
• Mindestflügelbreite bei der Verwendung der Einzugs-
dämpfung 700 mm
• mit Festverglasung: Deckenmontage
• ohne Festverglasung: Decken- und Wandmontage
• alle Abmessungen in Millimeter
• das Verhältnis der Türhöhe zur Türbreite darf 2,5:1
nicht überschreiten
Wichtige Informationen
Glasscheiben mit selbstreinigender Beschichtung können
mit diesem Beschlag nicht verwendet werden.
Die Glasscheibe muss bei der Montage der Rollapparate
und gegebenenfalls der Auslösebolzen für die Einzugs-
dämpfung im Bereich der Klemmflächen sauber und fett-
frei sein. Daher die Scheibe in diesem Bereich z. B. mit
Spezialreiniger oder Aceton reinigen. Weiter empfehlen
wir die Reinigung der Klemmflächen im Rollapparat und
dem Auslösebolzen.
Bei Anlagen die z. B. auf ein Mauerwerk auflaufen, oder
bei zweiflügeligen Anlagen empfehlen wir die Glasschie-
betüren zusätzlich an den Aufprallseiten mit einem Glas-
kantenschutz zu versehen.
Sicherheitsabstände (mindestens 25 mm) zwischen Tür-/
Muschelgriffe und Tür-/Schließkante, sind nach DGUV
Richtlinie einzuhalten.
2BANANA SLIDE
Banana Slide 50
Allgemeine Informationen / General information

Mindestflügelbreite bei der Verwendung der Einzugsdämpfung 700 mm.
Das Verhältnis der Türhöhe zur Türbreite darf 2,5:1 nicht überschreiten.
Minimum leaf width for use of the door damper 700 mm.
The relation of the door height to the door width may not cross 2,5:1
Lieferumfang
Scope of delivery
3
WWW.ONLEVEL.COM
Banana Slide 50
Lieferumfang / Scope of delivery
1. Laufschiene
2. Blende
3. Abdeckkappen
4. Rollapparat
4a. Zubehörset für Rollapparat
5. Stopper links
6. Stopper rechts
7. SmartGuide G
8. Unterer Anschlagpuffer*
(Art.-Nr. 200040006002/-03)
9. Klemmadapter
10. Einzugsdämpfer
11. Auslösebolzen
* nicht im Lieferumfang enthalten
1. Track
2. Pelmet
3. End caps
4. Trolley
4a. Trolley accessory set
5. End stop left
6. End stop right
7. SmartGuide G
8. Bottom buffer*
(Art. no. 200040006002/-03)
9. Clamp adapter
10. Door damper
11. Release bolt
* not included
Lieferumfang
Scope of delivery

GA1 (80*mm)
LW
L
GB
30 50
LW
Bohrhöhe (BH)
Drilling height (BH)
BH = LH + X + 35
Glashöhe (GH)
Glass height (GH)
GH = BH – 10 – 10,5
Glashöhe (GH)
Glass height (GH)
GH = LH – 10 – 32,5
Glasbreite Schiebetür (GB)
Door panel width (GB)
GB = LW + 50,00 + 30,00
Gewicht Schiebetür (G) = kg
Door panel weight (G) = kg
G = GH x GB x GD x 0,0000025
Laufschienenlänge (L) MG verdeckt
Track length (L) MG covered
L = GB + LW + 30,00
Durchgangsbreite (DB) MG verdeckt
Walk-through distance (DB) MG covered
DB = LW
Wand-/Deckenmontage - Nutzung der kompletten Durchgangsbreite, mit KWS Tür- oder Muschelgriff
(z. B. KWS 8270.. Türgriff / KWS 5252.. Muschelgriff)
Wall/ceiling installation - use of the entire passage width, with KWS door handle or KWS flush pull
(e.g. KWS 8270.. door handle / KWS 5252.. flush pull)
Legende:
LH = lichte Höhe
LW = lichte Weite
BH = Bohrhöhe
GH = Glashöhe
GB = Glasbreite Schiebetür
MG = Türgriff / Muschelgriff
L = Laufschienenlänge
GA1 = Griffabstand 1
GD = Glasdicke
DB = Durchgangsbreite
G = Gewicht in kg
Wandmontage
Wall installation
Deckenmontage
Ceiling installation
Legend:
LH = clear height
LW = clear width
BH = drill height
GH = glass height
GB = width door panel
MG = door handle / flush pull
L = track length
GA1 = handle distance 1
GD = glass thickness
DB = walk through distance
G = weight in kg
*bei Verwendung von z. B. KWS 8270.. Türgriff / KWS 5252.. Muschelgriff
*when using e.g. KWS 8270.. door handle / KWS 5252.. flush pull
4BANANA SLIDE
Banana Slide 50
Einbauschnitte und Berechnungen / Drawings and calculations

GA1 (80*mm)
LW
DB
30
GB
L
50
Bohrhöhe (BH)
Drilling height (BH)
BH = LH + X + 35
Glashöhe (GH)
Glass height (GH)
GH = BH – 10 – 10,5
Glashöhe (GH)
Glass height (GH)
GH = LH – 10 – 32,5
Glasbreite Schiebetür (GB)
Door panel width (GB)
GB = LW + 50,00 + 30,00
Gewicht Schiebetür (G) = kg
Door panel weight (G) = kg
G = GH x GB x GD x 0,0000025
Laufschienenlänge (L) MG halb verdeckt
Track length (L) MG half covered
L = GB + LW - GA1
Durchgangsbreite (DB) MG halb verdeckt
Walk-through distance (DB) MG half covered
DB = LW - GA1 - 30,00
Wand-/Deckenmontage - mit einseitig halb verdecktem KWS Muschelgriff in geöffneter Türstellung
(z. B. KWS 5252.. Muschelgriff)
Wall/ceiling installation - with one sided half covered KWS flush pull in open door position
(e.g. KWS 5252.. flush pull)
Legende:
LH = lichte Höhe
LW = lichte Weite
BH = Bohrhöhe
GH = Glashöhe
GB = Glasbreite Schiebetür
MG = Muschelgriff
L = Laufschienenlänge
GA1 = Griffabstand 1
GD = Glasdicke
DB = Durchgangsbreite
G = Gewicht in kg
Wandmontage
Wall installation
Legend:
LH = clear height
LW = clear width
BH = drill height
GH = glass height
GB = width door panel
MG = flush pull
L = track length
GA1 = handle distance 1
GD = glass thickness
DB = walk through distance
G = weight in kg
Deckenmontage
Ceiling installation
*bei Verwendung von z. B. KWS 5252.. Muschelgriff
*when using e.g. KWS 5252.. flush pull
5
WWW.ONLEVEL.COM
Banana Slide 50
Einbauschnitte und Berechnungen / Drawings and calculations

LW
L
DB GB
GA2 (60*mm)
30 50
GA1 (80*mm)
Bohrhöhe (BH)
Drilling height (BH)
BH = LH + X + 35
Glashöhe (GH)
Glass height (GH)
GH = BH – 10 – 10,5
Glashöhe (GH)
Glass height (GH)
GH = LH – 10 – 32,5
Glasbreite Schiebetür (GB)
Door panel width (GB)
GB = LW + 50,00 + 30,00
Gewicht Schiebetür (G) = kg
Door panel weight (G) = kg
G = GH x GB x GD x 0,0000025
Laufschienenlänge (L)
Track length (L)
L = GB + LW - GA1 - GA2
Durchgangsbreite (DB)
Walk-through distance (DB)
DB = LW - GA1 - GA2 - 30,00
Wand-/Deckenmontage - mit KWS Türgriff (z. B. KWS 8142.. Türgriff)
Wall/ceiling installation - with KWS door handle (e.g. KWS 8142.. door handle)
Deckenmontage
Ceiling installation
Legende:
LH = lichte Höhe
LW = lichte Weite
BH = Bohrhöhe
GH = Glashöhe
GB = Glasbreite Schiebetür
MG = Türgriff
L = Laufschienenlänge
GA1 = Griffabstand 1
GA2 = Griffabstand 2
GD = Glasdicke
DB = Durchgangsbreite
G = Gewicht in kg
Wandmontage
Wall installation
Legend:
LH = clear height
LW = clear width
BH = drill height
GH = glass height
GB = width door panel
MG = door handle
L = track length
GA1 = handle distance 1
GA2 = handle distance 2
GD = glass thickness
DB = walk through distance
G = weight in kg
*bei Verwendung von z. B. KWS 8142.. Türgriff
*when using e.g. KWS 8142.. door handle
6BANANA SLIDE
Banana Slide 50
Einbauschnitte und Berechnungen / Drawings and calculations

LW
50
L
GB
LW
4
GA1 (80*mm)
Wand-/Deckenmontage - Schiebetür auf z. B. Mauerwerk auflaufend, Nutzung der kompletten Durchgangsbreite,
mit KWS Tür- oder Muschelgriff (z. B. KWS 8270.. Türgriff / KWS 5252.. Muschelgriff)
Wall/ceiling installation - sliding door closes up to e.g. a wall, use of the entire passage width,
with KWS door handle or KWS flush pull (e.g. KWS 8270.. door handle / KWS 5252.. flush pull)
Bohrhöhe (BH)
Drilling height (BH)
BH = LH + X + 35
Glashöhe (GH)
Glass height (GH)
GH = BH – 10 – 10,5
Glashöhe (GH)
Glass height (GH)
GH = LH – 10 – 32,5
Glasbreite Schiebetür (GB)
Door panel width (GB)
GB = LW + 50,00 - 4,00
Gewicht Schiebetür (G) = kg
Door panel weight (G) = kg
G = GH x GB x GD x 0,0000025
Laufschienenlänge (L) MG verdeckt
Track length (L) MG covered
L = GB + LW
Durchgangsbreite (DB) MG verdeckt
Walk-through distance (DB) MG covered
DB = LW
Wandmontage
Wall installation
Deckenmontage
Ceiling installation
Legende:
LH = lichte Höhe
LW = lichte Weite
BH = Bohrhöhe
GH = Glashöhe
GB = Glasbreite Schiebetür
MG = Türgriff / Muschelgriff
L = Laufschienenlänge
GA1 = Griffabstand 1
GD = Glasdicke
DB = Durchgangsbreite
G = Gewicht in kg
Legend:
LH = clear height
LW = clear width
BH = drill height
GH = glass height
GB = width door panel
MG = door handle / flush pull
L = track length
GA1 = handle distance 1
GD = glass thickness
DB = walk through distance
G = weight in kg
*bei Verwendung von z. B. KWS 8270.. Türgriff / KWS 5252.. Muschelgriff
*when using e.g. KWS 8270.. door handle / KWS 5252.. flush pull
7
WWW.ONLEVEL.COM
Banana Slide 50
Einbauschnitte und Berechnungen / Drawings and calculations

GA1 (80*mm)
LW
450
DB GB
L
Bohrhöhe (BH)
Drilling height (BH)
BH = LH + X + 35
Glashöhe (GH)
Glass height (GH)
GH = BH – 10 – 10,5
Glashöhe (GH)
Glass height (GH)
GH = LH – 10 – 32,5
Glasbreite Schiebetür (GB)
Door panel width (GB)
GB = LW + 50,00 - 4,00
Gewicht Schiebetür (G) = kg
Door panel weight (G) = kg
G = GH x GB x GD x 0,0000025
Laufschienenlänge (L) MG halb verdeckt
Track length (L) MG half covered
L = GB + LW - GA1 + 4,00
Durchgangsbreite (DB) MG halb verdeckt
Walk-through distance (DB) MG half covered
DB = LW - GA1 + 4,00
Wand-/Deckenmontage - Schiebetür auf z. B. Mauerwerk auflaufend, mit einseitig halb verdecktem KWS Muschelgriff in
geöffneter Türstellung (z. B. KWS 5252.. Muschelgriff)
Wall/ceiling installation - sliding door closes up to e.g. a wall, with one sided half covered KWS flush pull in open door position
(e.g. KWS 5252.. flush pull)
Wandmontage
Wall installation
Deckenmontage
Ceiling installation
Legende:
LH = lichte Höhe
LW = lichte Weite
BH = Bohrhöhe
GH = Glashöhe
GB = Glasbreite Schiebetür
MG = Muschelgriff
L = Laufschienenlänge
GA1 = Griffabstand 1
GD = Glasdicke
DB = Durchgangsbreite
G = Gewicht in kg
Legend:
LH = clear height
LW = clear width
BH = drill height
GH = glass height
GB = width door panel
MG = flush pull
L = track length
GA1 = handle distance 1
GD = glass thickness
DB = walk through distance
G = weight in kg
*bei Verwendung von z. B. KWS 5252.. Muschelgriff
*when using e.g. KWS 5252.. flush pull
8BANANA SLIDE
Banana Slide 50
Einbauschnitte und Berechnungen / Drawings and calculations

GA1 (80*mm)
GA2 (60*mm)
L
DB GB
450
LW
Bohrhöhe (BH)
Drilling height (BH)
BH = LH + X + 35
Glashöhe (GH)
Glass height (GH)
GH = BH – 10 – 10,5
Glashöhe (GH)
Glass height (GH)
GH = LH – 10 – 33
Glasbreite Schiebetür (GB)
Door panel width (GB)
GB = LW + 50,00 - 4,00
Gewicht Schiebetür (G) = kg
Door panel weight (G) = kg
G = GH x GB x GD x 0,0000025
Laufschienenlänge (L)
Track length (L)
L = GB + LW - GA1 - GA2 + 4,00
Durchgangsbreite (DB)
Walk-through distance (DB)
DB = LW - GA1 - GA2 + 4,00
Wand-/Deckenmontage - Schiebetür auf z. B. Mauerwerk auflaufend, mit KWS Türgriff (z. B. KWS 8142.. Türgriff)
Wall/ceiling installation - sliding door closes up to e.g. a wall, with KWS door handle (e.g. KWS 8142.. door handle)
Wandmontage
Wall installation
Deckenmontage
Ceiling installation
Legende:
LH = lichte Höhe
LW = lichte Weite
BH = Bohrhöhe
GH = Glashöhe
GB = Glasbreite Schiebetür
MG = Türgriff
L = Laufschienenlänge
GA1 = Griffabstand 1
GA2 = Griffabstand 2
GD = Glasdicke
DB = Durchgangsbreite
G = Gewicht in kg
Legend:
LH = clear height
LW = clear width
BH = drill height
GH = glass height
GB = width door panel
MG = door handle
L = track length
GA1 = handle distance 1
GA2 = handle distance 2
GD = glass thickness
DB = walk through distance
G = weight in kg
*bei Verwendung von z. B. KWS 8142.. Türgriff
*when using e.g. KWS 8142.. door handle
9
WWW.ONLEVEL.COM
Banana Slide 50
Einbauschnitte und Berechnungen / Drawings and calculations

1
2
Die Stopper stirnseitig in die Laufschiene einschieben und am jeweiligen Schienenende grob positionieren, ohne eine Befestigungsbohrung zu verdecken.
Slide the stoppers into the track and roughly position them at the respective end of the track, without covering a fixing hole.
Die Klemmadapter (zwei Stück pro Meter) und Einzugsdämpfer wie dargestellt in die Laufschiene einschieben.
Slide the clamp adapters (two pieces per meter) and door dampers into the track.
Größe 2,5
Size 2,5
Größe 2,5 / 3
Size 2,5 / 3
10 BANANA SLIDE
Banana Slide 50
Montageschritte / Installation steps

3
Die Laufschiene ausrichten und (waagerecht und lotrecht) an die Wand bzw. Decke montieren.
Wichtig: Nur Befestigungsmaterial verwenden, das für den vorhandenen Untergrund geeignet ist.
Adjust the track and install it (level and plumb) to the wall or ceiling.
Note: Only use fixing material which is suitable for the existing subsurface.
11
WWW.ONLEVEL.COM
Banana Slide 50
Montageschritte / Installation steps

4
5
SW 8 / AF 8 Größe 3 / Size 3
Mit einem Lot die Position der unteren Führung ermitteln.
Bohrbild übertragen, bohren und die untere Führung befestigen.
Use a plumb bob to determine the position of the bottom guide.
Transfer the drilling pattern, drill and fix the bottom guide.
Die 2 Klemmplatten (2) und 4 Klemmschrauben (3) dem beiliegenden Zubehörset für Rollapparat entnehmen und wie in der Abbildung dargestellt ein-
setzen. Die Sicherungsschraube (1) an den Rollapparaten so weit herunter drehen, bis sie mit dem Rollapparat bündig ist.
Remove 2 clamping plates (2) and 4 clamping screws (3) from the enclosed trolley accessory set and adjust like shown in the figure. Lower the
safety screw (1) on the trolleys until it is flush with trolley.
12 BANANA SLIDE
Banana Slide 50
Montageschritte / Installation steps

4 Nm
7
4 Nm
6
Größe 3
Size 3
Alle Klemmflächen mit z. B. Spiritus oder Aceton reinigen. Die Rollapparate ganz auf die Glasscheibe aufschieben, bis die schwarzen Kunststoffhülsen (3)
kopfseitig an der Scheibe anliegen. Die Rollapparate jeweils 45 mm von den Stirnseiten positionieren. Es ist darauf zu achten, dass die Befestigungsplatte
(4) seitlich mit dem Rollapparat und an den Kunststoffhülsen (3) anliegt. Die Rollapparate auf der Glasscheibe mit einem Anzugsmoment von 4 Nm klem-
men, hierfür einen Drehmomentschlüssel mit Innensechskant (Größe 3) verwenden.
Clean the panel in this area, for example, with alcohol or acetone cleaner. Push the trolleys onto the glass panel until the black plastic sleeves (3) push
against the top of the panel. Position each of the trolleys 45 mm from the edge of the glass. It must be ensured that the clamping plate (4) is applied sideways
to the trolley and level with the plastic sleeves (3). Using a torque wrench with hexagon socket (size 3) tighten the clamp with a torque of 4 Nm.
Den Auslösebolzen mittig auf das Türblatt schieben und mit 4 Nm festziehen.
Push the release bolt centrally onto the glass panel and tighten with 4 Nm.
Größe 3
Size 3
13
WWW.ONLEVEL.COM
Banana Slide 50
Montageschritte / Installation steps

8
9
SW 8
AF 8
SW 8
AF 8
Wichtig: Die Laufflächen der Schiene und die Rollen vor
dem Einsetzen des Türblattes säubern.
Die Rollapparate sind mit wartungsfreien Kugellagern
ausgestattet und dürfen nicht nachgefettet werden.
Das Türblatt in die Laufschiene hängen und über die Sechs-
kantschraube (2) mit Hilfe einer Wasserwaage ausrichten.
Die Sicherungsschrauben (1) so weit hoch drehen, bis ein leichter
Kontakt zur Laufschiene besteht, dann diese wieder um eine
½ Umdrehung zurück drehen.
Wichtig: Die Sicherungsschrauben verhindern das Aus-
heben der Tür bei unsachgemäßer Betätigung.
Die Stopper in der Laufschiene am jeweiligen Schienenende so
positionieren, dass die gewünschte Türöffnung freigegeben wird
und wie folgt klemmen: zuerst die obere Schraube (5a) des Stop-
pers anziehen, bis sich das Bauteil in der Schiene gesetzt hat.
Nun die untere Schraube (5b) leicht anziehen. Anschließend bei-
de Schrauben eine ¼ Umdrehung nachziehen.
Important: Clean running track before inserting door.
All trolleys are equipped with maintenance free bea-
rings and must not be greased.
Position the door panel in the track and align using the hexagon
screw (2) and a level. Turn the locking screws (1) until they are in light
contact with the track, then turn them back again by a ½ a turn.
Important: The locking screws serve as the anti-jump sys-
tem and prevent the door from jumping out if improperly
used.
Position the trolley stops in the track at the respective end of the
track so that the required door opening is achieved and clamp as
follows: screw the top screw (5a) on the stopper until the compo-
nent has set in the track. Now tighten the bottom screw (5b)
slightly. Then re-tighten both screws by turning them an additional
¼ turn.
Den Auslösebolzen mittels Einstellplatte in der Höhe so einstellen, dass der Auslösebolzen in der Fanggabel vom Einzugsdämpfer greift und diesen bei Be-
tätigung spannt.
Adjust release bolt in height via setting plate, so that the release bolt engages in the catch fork of the door dumper and tightens it when actuated.
Größe 2,5 / 3
Size 2,5 / 3
14 BANANA SLIDE
Banana Slide 50
Montageschritte / Installation steps

10
11
Die Klemmadapter wie dargestellt an der Laufschiene verteilen und fixieren.
Spread the clamp adapters on the track and fix them as shown.
Das Türblatt mit dem Auslösebolzen in den rechten gelösten Einzugsdämpfer wie dargestellt einschieben. Türe mit dem Einzugsdämpfer gegen den rechten
Stopper schieben und die Befestigungsschrauben vom Einzugsdämpfer festziehen. Den Vorgang für den linken Einzugsdämpfer wiederholen.
Slide the door with the release bolt into the loose right damper. Slide the door with the damper to the right end-stop and tighten the damper screws. Repeat
these steps on the other side for the left damper.
Größe 3 / Size 3
Größe 2,5 / Size 2,5
15
WWW.ONLEVEL.COM
Banana Slide 50
Montageschritte / Installation steps

12
13
Größe 2
Size 2
Bei Verwendung der optionalen Abdeckkappen:
Abdeckkappen an der Laufschiene anbringen und festschrauben.
When using the optional end caps:
Mount end caps on the track and screw tight.
Blende nach Abbildung unten an den Klemmadaptern ansetzen
und an der oberen Klemmstelle andrücken.
Place the pelmet at the bottom part of the clamp adapter and
clip-on at the top.
16 BANANA SLIDE
Banana Slide 50
Montageschritte / Installation steps

17
WWW.ONLEVEL.COM

Mindestflügelbreite bei der Verwendung der Einzugsdämpfung 700 mm.
Das Verhältnis der Türhöhe zur Türbreite darf 2,5:1 nicht überschreiten.
Minimum leaf width for use of the door damper 700 mm.
The relation of the door height to the door width may not cross 2,5:1
Lieferumfang
Scope of delivery
18 BANANA SLIDE
Banana Slide 50 mit Festteil / Banana Slide 50 with fixed glazing
Lieferumfang / Scope of delivery
1. Laufschiene (mit Festteil)
2. Blende
3. Abdeckkappen
4. Rollapparat
4a. Zubehörset für Rollapparat
5. Stopper links
6. Stopper rechts
7. SmartGuide G
8. Klemmadapter
9. Einzugsdämpfer
10. Auslösebolzen
11. U-Schiene für Festteil
12. T-Blende
13. Befestigungsklammern für Abdeckprofil
1. Track (with fixed glazing)
2. Pelmet
3. End caps
4. Trolley
4a. Trolley accessory set
5. End stop left
6. End stop right
7. SmartGuide G
8. Clamp adapter
9. Door damper
10. Release bolt
11. U-Track for fixed glazing
12. T-shaped pelmet
13. Clamps for cover profile

GA1 (80*mm)
LW
DB
30
5030
GB L
S
Laufschienenlänge (L)
Track length (L)
L = LW + 60,00
Länge T-Blende (T)
T-shaped pelmet length (T)
T = L - S
Glasbreite Schiebetür (GB) max. DB, MG verdeckt
Door panel width (GB) max. DB, MG covered
GB = LW + 60,00 + 50,00
2,00
Gewicht Schiebtür (G) in kg MG verdeckt
Door panel weight (G) in kg MG covered
G = GH x GB x GD x 0,0000025
Glasbreite Festteil (S) max. DB, MG verdeckt
Glass width fixed glazing (S) max. DB, MG covered
S = LW + 60,00 + 50,00
2,00
Länge U-Schiene für Festteil (UF) MG verdeckt
U-track length for fixed glazing (UF) MG covered
UF = S
Durchgangsbreite (DB) MG verdeckt
Walk-through distance (DB) MG covered
DB = L - S - 30,00
Deckenmontage - Nutzung der kompletten Durchgangsbreite, mit KWS Tür- oder Muschelgriff
(z. B. KWS 8270.. Türgriff / KWS 5252.. Muschelgriff)
Ceiling installation - use of the entire passage width, with KWS door handle or KWS flush pull
(e.g. KWS 8270.. door handle / KWS 5252.. flush pull)
Glashöhe (GH)
Glass height (GH)
GH = LH – 10 – 32,5
GHS = GH
Legende:
LH = lichte Höhe
LW = lichte Weite
BH = Bohrhöhe
GH = Glashöhe
GB = Glasbreite Schiebetür
MG = Türgriff / Muschelgriff
L = Laufschienenlänge
GA1 = Griffabstand 1
GD = Glasdicke
DB = Durchgangsbreite
G = Gewicht in kg
T = T-Blende
S = Festteil
UF = U-Schiene für Festteil
GHS = Glashöhe Festteil
Legend:
LH = clear height
LW = clear width
BH = drill height
GH = glass height
GB = width door panel
MG = door handle / flush pull
L = track length
GA1 = handle distance 1
GD = glass thickness
DB = walk through distance
G = weight in kg
T = t-shaped pelmet length
S = fixed glazing
UF = u-track for fixed glazing
GHS = fixed glazing height
*bei Verwendung von z. B. KWS 8270.. Türgriff / KWS 5252.. Muschelgriff
*when using e.g. KWS 8270.. door handle / KWS 5252.. flush pull
19
WWW.ONLEVEL.COM
Banana Slide 50 mit Festteil / Banana Slide 50 with fixed glazing
Einbauschnitte und Berechnungen / Drawings and calculations

GA1 (80*mm)
GA2 (60*mm)
LW
DB
L
GB 30
50
30
S
Glashöhe (GH)
Glass height (GH)
GH = LH – 10 – 32,5
GHS = GH
Laufschienenlänge (L)
Track length (L)
L = LW + 60,00
Länge T-Blende (T)
T-shaped pelmet length (T)
T = L - S
Glasbreite Schiebetür (GB) max. DB
Door panel width (GB) max. DB
GB = LW + 90,00 + GA1 + GA2 - 50,00
2,00
Gewicht Schiebtür (G) in kg
Door panel weight (G) in kg
G = GH x GB x GD x 0,0000025
Glasbreite Festteil (S) max. DB
Glass width fixed glazing (S) max. DB
S = LW + 30,00 - GA1 - GA2 + 50,00
2,00
Länge U-Schiene für Festteil (UF)
U-track length for fixed glazing (UF)
UF = S
Durchgangsbreite (DB)
Walk-through distance (DB)
DB = LW - GA1 - GA2 + 30,00
2
Legende:
LH = lichte Höhe
LW = lichte Weite
BH = Bohrhöhe
GH = Glashöhe
GB = Glasbreite Schiebetür
MG = Türgriff
L = Laufschienenlänge
GA1 = Griffabstand 1
GA2 = Griffabstand 2
GD = Glasdicke
DB = Durchgangsbreite
G = Gewicht in kg
T = T-Blende
S = Festteil
UF = U-Schiene für Festteil
GHS = Glashöhe Festteil
Deckenmontage - mit KWS Türgriff (z. B. KWS 8142.. Türgriff)
Ceiling installation - with KWS door handle (e.g. KWS 8142.. door handle)
Legend:
LH = clear height
LW = clear width
BH = drill height
GH = glass height
GB = width door panel
MG = door handle
L = tack length
GA1 = handle distance 1
GA2 = handle distance 2
GD = glass thickness
DB = walk through distance
G = weight in kg
T = T-shaped pelmet length
S = fixed glazing
UF = u-track for fixed glazing
GHS = fixed glazing height
*bei Verwendung von z. B. KWS 8142.. Türgriff
*when using e.g. KWS 8142.. door handle
20 BANANA SLIDE
Banana Slide 50 mit Festteil / Banana Slide 50 with fixed glazing
Einbauschnitte und Berechnungen / Drawings and calculations
Other manuals for Banana Slide 50
1
Table of contents
Other ONLEVEL Door Opening System manuals
Popular Door Opening System manuals by other brands

Dormakaba
Dormakaba 8900 TDE installation instructions

Dormakaba
Dormakaba GSR-EMR XEA BG Mounting instructions

Chamberlain
Chamberlain T user guide

Next Systems
Next Systems 900 INSTRUCTIONS MANUAL FOR THE USE & MAINTENANCE

LCN
LCN 1450 Track Series installation instructions

Sargent
Sargent 1431 series installation instructions