Electromagnetic Lock Series
EXML600-GATE & EXML1200-GATE Series (Monitored)
External Monitored Magnetic Lock Wiring Instructions
Power Input
12VDC or 24VDC input
Lock Status Sensor
1: Normally open switch: NO & C
2: Normally closed switch: NC & C
C: Contacts:
•Relay voltage free contacts are rated 1A at 24VDC for safe operation, do not exceed this
•If you require a normally open switch, connect the wires from the system to COM and NO
•If you require a normally closed switch, connect the wires from the system to COM and NC
12V Wiring Diagram
24V Wiring Diagram
Red to +24VDC
Yellow & Blue together
Black to -VE
White COM
Brown NC
Green NO
Red & Yellow to +12VDC
Blue & Black to –VE
White COM
Brown NC
Green NO
Wiring the Back-EMF Protection Diode
•Connect the back-EMF Diode in reverse polarity with respect to the magnetic lock polarity.
•The end with the Silver (Grey) Ring connects the (+)ve of the magnetic lock.
Power
Supply
(+)
(-)
Maglock
(+)
(-)
Back-EMF protection diode
EXML600-GATE
EXML1200-GATE
A. Handle the
equipment with care,
damaging the surface
of the magnet or
armature plate may
reduce locking
efficiency.
B. The magnet is
mounted rigidly to the
frame, whereas the
armature plate must
be mounted to the
gate using the items
provided to allow it to
pivot about its centre.
This allows it to
compensate for wear
and misalignment.
IMPORTANT REMINDERS
B: 24VDC Input:
•Required power 0.25Amp (Minimum)
•Connect the positive (+) lead from a 24VDC power source to +
•Connect the ground (-) lead from a 24VDC power source to –
A: 12VDC Input:
•Required power 0.5Amp (Minimum)
•Connect the positive (+) lead from a 12VDC power source to +
•Connect the ground (-) lead from a 12VDC power source to –