-1-
INSTALLATION INSTRUCTIONS
No.59-2069-1 1701-31
INSTALLATIONS
PCU-5 ×1, Putty ×2, Insulation Plate ×1
Power Convertor Unit
PCU-5
PARTS IDENTIFICATION
BATTERY OPERATED
PHOTOELECTRIC DETECTOR
Smart Line series
OPTION
BATTERY OPERATED
PHOTOELECTRIC DETECTOR
Smart Line series
OPTION
™
™
1 2 3 Connect the connector cable to the
terminals of PCU-5.
4 5
78 9
6
Note>>
Put the cables in order not to be caught
between the main unit and cover.
Using a screwdriver or similar tool, break
the knockout position in the back box as
shown.
Open the battery plate and then route the
control panel wires from the rear of the back
box through the knockout holes.
Adjust the wires so that they extend about
100 mm from the holes.
Fill the holes with the wires using the
supplied putty.
Close the battery plate and connect PCU-5
male connector to the female connector of
the battery plate.
Route the three connectors of the back box
through the slit on the upper part of the
main unit of the receiver. For the transmitter,
wire the two connectors in the same way.
Attach the connectors.
Insert the insulation plate and PCU-5 as
illustrated. And then connect the wires to
the PCU-5 terminals.
Route connector cables (Alarm, Low battery
and Tamper, included in SL-100/200TNR) in
the back box through the hole to the battery box.
Controlpanel
For the receiver, the step 2 & 3 are applied. For the transmitter, jump to the step 4.
CP
Side
DETECTOR
Side
The length of the wire
should be about 100 mm.
Insulation sheet
Voltage convertor unit used to enable wired
operation of the detector.
For SL-100/200TNR only
Insert the PCU-5
board to the left side.
CP Side Detector Side
www.GateOpenerSafety.com | (800) 878-7829 | [email protected]
-2-
SYSTEM DIAGRAM
FUNCTION TO TRANSMIT LOW-BATTERY
SIGNAL
SPECIFICATIONS
DIMENSIONS
Unit: mm (inch)
Current draw
Power input
Output voltage
Output current
Alarm output
D.Q. output
Low battery output
Tamper output
Operating temperature
Operating humidity
Dimension
WIRING DISTANCE BETWEEN POWER
SUPPLY AND DETECTOR
0.33mm2(AWG22)
0.52mm2(AWG20)
0.83mm2(AWG18)
1.31mm2(AWG16)
180m (600ft.)
280m (900ft.)
450m (1,500ft.)
700m (2,300ft.)
1,200m (4,000ft.)
1,800m (6,000ft.)
3,000m (10,000ft.)
4,500m (14,500ft.)
10.5 - 30 VDC
80mA (max.)
Approx. 3.9 VDC
10mA (max.)
Form C relay ; 30VDC. 0.2A
Unused (Form C relay ; 30 VDC 0.2 A)
N.C. relay ; 30VDC. 0.2A
N.C. relay ; 30VDC. 0.2A
-20°C to 60°C (-4°F to 140°F)
95% (max.)
H×W×D mm (inch): 71 (2.8) × 53 (2.1) × 20 (0.8)
12VDC 24VDC
Wire size Power supply voltage
71 (2.8)
20 (0.8)
53 (2.1)
Receiver
Red
Black
Main unit
Yellow
Orange
Brown
Green
Blue
Purple
Gray
Power
Power
10 - 30V
Alarm
Back box
PCU-5
Control panel
+
Low battery
Tamper
DQ*
UNUSED
Alarm
Low battery
Tamper
DQ*
* UNUSED
The DQ function is not provided
with the SL-TNR.
Transmitter
Red
Black
Main unit
from PCU-5
Back box
Battery plate PCU-5
Battery plate
PCU-5
Low battery signal
Control
panel
The low-battery signals are transmitted from the transmitter
using IR beams.This function enables to eliminate the need
to install a wireless transmitter in the transmitter.
–
C
NC
NO
C
NC
NO
C
NC
C
NC
+
–
C
C
NC
C
NC
C
NC
NC
Do not insert batteries into the unit
which is operated by PCU-5.
Doing so may result in fire or explosion.Warning
Transmitter * Receiver
* Even if the receiver is powered by PCU-5, low-battery wiring
is required to report the low-battery status of the transmitter.
www.GateOpenerSafety.com | (800) 878-7829 | [email protected]

Popular Heater manuals by other brands

Ambirad Vision VSO Series Assembly & instruction manual

Ambirad

Ambirad Vision VSO Series Assembly & instruction manual

Therma Q TechPaq Spa Pack installation manual

Therma Q

Therma Q TechPaq Spa Pack installation manual

Silvercrest SOR 2400 D2 Operating & safety guide

Silvercrest

Silvercrest SOR 2400 D2 Operating & safety guide

System air ZRS manual

System air

System air ZRS manual

ProFusion SHAG-L02F instruction manual

ProFusion

ProFusion SHAG-L02F instruction manual

RealFlame ELEMENT 1200 Installation & operating manual

RealFlame

RealFlame ELEMENT 1200 Installation & operating manual

Sunway SWH-RE1000 Operating	 instruction

Sunway

Sunway SWH-RE1000 Operating instruction

Concept2 KS4000 manual

Concept2

Concept2 KS4000 manual

Silvercrest SOR 2400 D2 Operation and safety notes

Silvercrest

Silvercrest SOR 2400 D2 Operation and safety notes

Red Stone SH-J12 user manual

Red Stone

Red Stone SH-J12 user manual

Warmtech TCPM2000 instruction manual

Warmtech

Warmtech TCPM2000 instruction manual

New Air AH-400 owner's manual

New Air

New Air AH-400 owner's manual

ENERCORP HeatStar HS180ID Operating instructions and owner's manual

ENERCORP

ENERCORP HeatStar HS180ID Operating instructions and owner's manual

MrHeater Mr. Heater 1000ID Operating instructions and owner's manual

MrHeater

MrHeater Mr. Heater 1000ID Operating instructions and owner's manual

MALTEC CH7000DWB instruction manual

MALTEC

MALTEC CH7000DWB instruction manual

Heatwagon HVF210HD Installation and maintenance manual

Heatwagon

Heatwagon HVF210HD Installation and maintenance manual

Shizuoka Seiki VAL6 owner's manual

Shizuoka Seiki

Shizuoka Seiki VAL6 owner's manual

New Air AH-400 owner's manual

New Air

New Air AH-400 owner's manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.