OptoSigma JD-101 User manual

SC29101-K13-18002
-1-
JOG DIAL CONTROLLER
User’s Manual
JD-101

SC29101-K13-18002
-2-
Notes regarding these materials
・ These materials are intended as a reference to assist our customers in the use of the
SIGMAKOKI CO., LTD. Product best suited to the customer’s application; they do
not convey any license under any intellectual property rights, or any other rights,
belonging to SIGMAKOKI CO., LTD. or a third party.
・ SIGMAKOKI CO., LTD. assumes no responsibility for any damage, or infringement
of any third-party’s rights, originating in the use of any product data, diagram, charts,
programs, or algorithms contained in these materials.
・ All information contained in these materials, including product data, diagrams, charts,
programs and algorithms represents information on products at the time of
publication of these materials, and are subject to change by SIGMAKOKI CO.,LTD.
without notice due to product improvements or other reasons.
・ When using any or all of the information contained in these materials, including
product data, diagrams, charts, programs, and algorithm, please be sure to evaluate
all information and products. SIGMAKOKI CO., LTD. assumes no responsibility for
any damage, liability or other loss resulting from the information contained herein.
・ SIGMAKOKI CO., LTD. products are not designed or manufactured for use in
equipment or system that is used under circumstances in which human life is
potentially at stake. SIGMAKOKI CO., LTD. products cannot be used for any specific
purposes, such as apparatus or systems for transportation, vehicular, medical,
aerospace, nuclear, or undersea repeater use.
・ The prior written approval of SIGMAKOKI CO., LTD. is necessary to reprint or
reproduce in whole or in part these materials.
・ If these products or technologies are subject to the Japanese export control
restrictions, they must be exported under a license Japanese government and cannot
be imported into a country other than the approved destination.
Any diversion or reexport contrary to the export control laws and regulations of Japan
and/ or the country of destination is prohibited.

SC29101-K13-18002
-3-
For Your Safety
Before using this product, read this manual and all warnings or cautions in the documentation provided.
Only Factory Authorized Personnel should be changes and/or adjust the parts of controller.
The Symbols Used in This Manual
!WARNING !CAUTION
This symbol marks warnings that should be read
and used to prevent serious injury or death.
This symbol indicates where caution should be
used to avoid possible injury to yourself or others,
or damage to property.
The above indications are used together with the following symbols to indicate the exact nature of the
warning or caution.
Examples of Symbols Accompanying Warnings and Cautions
△
Symbols enclosed in a triangle indicate warnings and cautions. The
exact nature of the warning or caution is indicated by the symbol inside
(the symbol at left indicates risk of electrocution).
○Symbols enclosed in a circle mark indicate prohibitions(actions that
must not be performed).The exact nature of the prohibition is indicates
by the symbol inside or next to the circle mark (the symbol at left
indicates that the product must not be disassembled).
●Symbols inside a black circle mark actions that must be performed to
ensure safety. The exact nature of the action that must be performed is
indicated by the symbol inside (the symbol at left is used in cases in
which the AC adapter must be unplugged to ensure safety).
Symbols on the product
The symbol mark on the product calls your attention. Please refer to the manual, in the case
that you operate the part of the symbol mark on the product.
This symbol labeled on the portion calls your attention.
!

SC29101-K13-18002
-4-
Disclaimer of Liability
① SIGMAKOKI CO., LTD. does not accept liability for damages resulting from the use of this product or
the inability to use this product.
② SIGMAKOKI CO., LTD. does not accept liability for damages resulting from the use of this product that
deviates from that described in the manual.
③ SIGMAKOKI CO., LTD. does not accept liability for damages resulting from the use of this product in
extraordinary conditions, including fire, earthquakes, and other acts of God, action by any third party,
other accidents, and deliberate or accidental misuse.
④ If the equipment is used in a manner not specified by the SIGMAKOKI CO., LTD., the protection provided
by the equipment may be impaired.
WARNING
●Do not use this product in the presence of flammable gas, explosives, or corrosive substances, in areas
exposed to high levels of moisture or humidity, in poorly ventilated areas, or near flammable materials.
●Do not connect or check the product while the power is on.
●Installation and connection should be performed only by a qualified technician.
●Do not bend, pull, damage, or modify the power or connecting cables.
●Do not touch the products internal parts.
●Connect the earth terminal to ground.
●Should the product overheat, or should you notice an unusual smell, heat, or unusual noises coming from
the product, turn off the power immediately.
●Do not turn on the power in the event that it has received a strong physical shock as the result of a fall or
other accident.
●Do not touch the stage while operation.
●Use dry clothes only for cleaning the equipment.
!

SC29101-K13-18002
-5-
table of contents
Chapter 1: Before You Begin...................................................................................................... 6
1-1. Overview............................................................................................................................ 6
1-2. Connecting method.......................................................................................................... 7
Chapter 2: Notes on Use............................................................................................................. 7
2-1. Name of each part ............................................................................................................ 7
2-2. Operating method ............................................................................................................ 8
Chapter 3: Specifications ......................................................................................................... 10
3-1. Specifications ................................................................................................................. 10
3-2. Connector pin number and signal................................................................................ 10
3-3. Exterior Dimensions ...................................................................................................... 11

SC29101-K13-18002
-6-
Chapter 1: Before You Begin
1-1. Overview
This product have JOG-Dial type UI. It’s have display.
It can be connected to our stage controller, SHOT-30* series and SHOT-702 and PGC-04-U
and HSC-103.
The operation box, connected to the controller via a cable, provides remote operation.
This means that the joystick allows you to work near the motorized stage while checking its
behavior even if the controller and the motorized stage are away from each other.
When you use JD-101, you can use when Table1-1 controller version.
Table1-1
Controller version
SHOT-302GS/304GS Ver1.20~
SHOT-702 Ver1.05~
PGC-04-U Ver1.02~
HSC-103 Ver1.01~
This product This contains items such as the following.
□JD-101 1
□User’s manual (This document) 1
When you use this product, you need MDR14-CA cable.

SC29101-K13-18002
-7-
1-2. Connecting method
This product
is connected to the controller with MDR14-CA cable.
① Connect a standard cable (MDR14-CA-*) to the connector on the rear panel of the
JD-101.
② Connect the cable from the JS-301 to the “JOYSTICK” or “OPTION”of the connector on
the front panel of the SHOT-30X series and PGC-04-U controller.
(In the case of SHOT-702/HSC-103, it becomes the rear panel part.)
③ Turn power switch of the controller on.
Among the LED of “AXIS”, the LED of “1” will light green.
Chapter 2: Notes on Use
2-1. Name of each part
Fig.2-1 Name of each part
Be sure the controller is off when you connect this product. You may not
able to use the buttons and so on this product if you connect or disconnect
either device while the controller is on.

SC29101-K13-18002
-8-
2-2. Operating method
①【MODE】button
Change an operation mode of the controller.
HOST→MANUAL・・・
Refer to a User’s Manual of SHOT-302GS/SHOT-304GS for various modes.
NOTE) IN SHOT-702/PGC-04-U/HSC-103, the MODE change is invalid.
②【RATE】button
Switch the amount of movement of the stage for the dial operation.
The LED indicator lights up : 5pulse/ 1click for JOG-dial.(High-RATE)
The LED indicator lights down: 1pulse/ 1click for JOG-dial.(Normal-RATE)
③【AXIS-SEL】button
Selects the axis operated by this button.
Change the number of lightning of AXIS/SPEED LED indicator by the AXIS-SEL button every
time pushing the button. (1→2→3→4→1・・・)
When "●" position means Shining LED. Position of Shining AXIS/SPEED LED means AXIS.
●〇〇〇 AXIS =1
〇●〇〇 AXIS =2
〇〇●〇 AXIS =3
〇〇〇● AXIS =4
Fig.2-2-1 Position of Shining AXIS/SPEED LED means AXIS.
NOTE) When the axis which doesn't exist in case of SHOT-302GS, SHOT-702
and HSC-103 (2 axis or 3 axis) is chosen, a controller doesn't move.

SC29101-K13-18002
-9-
④【SPEED】button
Cycle through “SPEED 1/2/3/4” settings stored in controller’s memory switches
(1→2→3→4→1・・・).
When "●" position means Shining LED. Number of Shining AXIS/SPEED LED means speed
value.
●〇〇〇 SPEED=1
●●〇〇 SPEED=2
●●●〇 SPEED=3
●●●● SPEED=4
Fig.2-2-2 Number of Shining AXIS/SPEED LED means speed value.
After about 3 seconds, the AXIS / SPEED LED on the selected axis is light on.
NOTE) Because there is not speed indication, in the case of SHOT-702, PGC-04-U,
HSC-103, a controller is invalid.
⑤,⑥【JOG-】/【JOG+】button
Enables operation of selects-axis. Pressing of this button continuously moves the stage
continuously. Releasing this button stops the stage.
⑦AXIS/SPEED LED
Change the number of lightning of AXIS/SPEED LED indicator by the【AXIS-SEL】button every
time pushing the button. (1→2→3→4→1・・・).
When you press the 【SPEED】button, the set value of SPEED is displayed.
⑧JOG DIAL
The JOG DIAL for operating the stage.
Left rotation : -direction
Right rotation : + direction
⑨Connection connector
It is a connector to be connected with a controller and an MDR14-CA-* cable.
When turn power switch , Please don't touch JOG DIAL.
When you use this product, you need MDR14-CA cable.

SC29101-K13-18002
-10-
Chapter 3: Specifications
3-1. Specifications
Power supply Supplied from the controller via connection cable
Operating temperature 5~40℃
Storage temperature -20~60℃
Altitude up to 2000m
Indoor use only
Installation category Ⅱ
Pollution degree 2
Ambient humidity 20~80%RH (no condensation)
External dimensions 130W×145D×56H [mm](excluding projections)
Weight[kg] About 0.6 [kg] However, it does not include cables
Electrostatic discharge EN61000-4-2(2009) Level 2
3-2. Connector pin number and signal
Table3-2 Connector pin assignment
Pin number Signal name Pin number Signal name
1 SG 8 SG
2 +5V 9 +5V
3 TXD+ 10 TXD-
4 RXD+ 11 RXD-
5 STOP 12 CONNECT-
6 - 13 -
7 - 14 -

SC29101-K13-18002
-11-
3-3. Exterior Dimensions
Fig.3-3 Exterior Dimensions

SC29101-K13-18002
-12-
SIGMAKOKI CO., LTD.
http://www.global-optosigma.com
Tokyo Head office
SIGMAKOKI Tokyo Head office 1-19-9, Midori, Sumida-ku, Tokyo
130-0021, JAPAN
TEL:+81-3-5638-8228 FAX:+81-3-5638-6550 E-mail:international@sigma-koki.com
Osaka Branch
4-9-28, Nishi-Nakajima, Yodogawa-ku, Osaka 532-0011, JAPAN
TEL:+81-6-6307-4835 FAX:+81-6-6307-4834
Kyushu Sales office
3-17, Hie-machi, Hakata-ku, Fukuoka-shi, Fukuoka 812-0014,
JAPAN
TEL:+81-92-481-4300 FAX:+81-92-481-4310
Technology center
1-1 Yatsukaho, Hakusan-shi, Ishikawa-ken 924-0838, JAPAN
2019.4 First edition
Table of contents
Other OptoSigma Controllers manuals