Orion MCU User manual

Orion-MCU™ Quick Start Guide
The Most Affordable HD Video Conferencing System for your Enterprise !
1
Read Before Operation
Connecting Orion-MCU to the Network
Step 1: Follow the precautionary and safety instructions
Please follow the precautionary and system safety instructions that appear
in Appendix A of the Orion-MCU User Manual. To install the system, choose
a clean, dust-free area that is well ventilated. Avoid areas where heat,
electrical noise and electromagnetic fields are generated.
If you intend to install the system in a rack, choose a location near a
grounded power outlet, and follow the instructions in Appendix B of the
Orion-MCU User Manual.
Step 2: Unpack your Orion-MCU system
Step 3: Connect the cables
Connect the cables to your Orion-MCU system:
1. Connect the short CAT-6 cable that is provided with the system in a
loop as shown at the image below.
2. Connect the Orion-MCU “LAN” port to the Ethernet port of your
computer using a CAT-5/6 cable.
3. Connect the power cable first to the Orion-MCU and then to the
power outlet. Press the power-on button located on the front
panel of the Orion-MCU to start the system. (server and application
load time is approximately 5 minutes).
Step 4: Apply the static IP address: “192.168.0.2” to your Computer
Change your computer’s network settings and apply the following static IP
address: “192.168.0.2”.

Orion-MCU™Quick Start Guide
The Most Affordable HD Video Conferencing System for your Enterprise!
2
Step 5: Change Orion-MCU’s IP address
Orion-MCU is provided with a default IP address “192.168.0.1” that should
be modified before using the system.
To change the IP address:
1. In a web browser, navigate to the default IP address - 192.168.0.1.
Upon the appearance of the login screen, enter the default user
name and password (admin, admin).
Note: Orion-MCU web based GUI supports Internet Explorer 8 or
newer, Google Chrome 20 or newer, Mozilla Firefox 14 or newer and
Safari 5 or newer.
2. Select System Settings > Network Settings, as shown in the figure
below:
3. Click Edit and then modify the IP Address field.
4. Click Save . A confirmation message appears as shown in the
figure below.

Orion-MCU™Quick Start Guide
The Most Affordable HD Video Conferencing System for your Enterprise!
3
5. Click OK.
The system reboots and the changes are applied.
Note: If DHCP was chosen, the simplest way to see the Orion-MCU IP
Address is to connect a monitor and restart the machine. The IP Address
will appear in the Login Screen at the end of the system load.
Step 6: Connect to the Orion-MCU IP Address from your Network
Restore the original network configuration on your computer, and connect
the Orion-MCU to your network.
Connect to the Orion-MCU management system by entering the Orion-
MCU’s IP address in a web browser.
The Orion-MCU is now connected to your network

Orion-MCU™Quick Start Guide
The Most Affordable HD Video Conferencing System for your Enterprise!
4
Conducting a Test Video Conference
The fastest way to check video conference connectivity is to connect to a
predefined conference room on the Orion-MCU.
To aid in testing the system, install Linphone. Linphone is a free, open-
source client from Belledonne Communications.
Linphone Installation:
Download Linphone using this link
http://download-
mirror.savannah.gnu.org/releases/linphone/3.5.x/win32/linphone-3.5.2-
setup.exe
Download H264 using this link:
http://download.savannah.gnu.org/releases/linphone/plugins/win32/msx2
64-1.4.2-setup.exe
Install both files and restart Linphone by quitting the application (from
windows, right click and choose “quit”), and launching it again.
Linphone Configuration:
1. Under Options, make sure the Enable Video item is checked, then click
on Options Preferences.
2. In the First Tab (Upper left), make sure Send DTMFs as SIP Info is
checked. Don’t change any other parameter. (inband dtmf’s have
some issues with LinPhone)
3. In the Multimedia settings tab, make sure your capture device is your
microphone and that the video input device is your USB or Integrated
Camera. For Video resolution, please choose VGA.
4. In the Codecs Tab, from the dropdown select the Audio and Video
Codecs and set them as follows:
a. Voice: Enable only PCMA and PCMU audio codecs (disable and
move down all the rest)
b. Video: Enable only H264 for Video codec (disable and move down
all the rest)
5. Press Done.

Orion-MCU™Quick Start Guide
The Most Affordable HD Video Conferencing System for your Enterprise!
5
Testing a Video Call
1. To test IVVR scenarios, dial 500@<Orion-MCU IP Address> from
Linphone.
a. Enter the conference Number 100# from the LinPhone keypad
when prompted.
b. Enter the conference PIN 1# from the LinPhone keypad when
prompted.
c. You should see the image of your camera and the call should be
active.
d. Additional clients can connect to the conference.
2. To test direct connectivity dial 500*100*1@<Orion-MCU IP Address>
from Linphone.
a. You should be placed in the conference immediately. (IVVR is
bypassed)
b. Additional clients can connect to the conference.

Orion-MCU™Quick Start Guide
The Most Affordable HD Video Conferencing System for your Enterprise!
6
The Orion-MCU Video Conferencing Bridge has been tested
and is working properly!