Outdoor GreatRoom Company Crystal Fire Plus User manual

www.outdoorrooms.com
!!
FOR OUTDOOR USE ONLY.
Installation and service must be performed by a
qualified installer, service agency, or the gas
supplier.
!! !!
DANGER
• Important operating instructions included.
• Read, understand, and follow these
instructions for safe installation and operation.
INSTALLER: Leave manual with the appliance.
CONSUMER: Retain this manual for future
reference.
CAUTION
Crystal Fire® Plus Direct Spark Ignition (DSI) System
!!
!! DANGER
WARNING
WARNING
CARBON MONOXIDE HAZARD
This appliance can produce carbon monoxide
which has no odor.
Using it in an enclosed space can kill you.
Never use this appliance in an enclosed space
such as a camper, tent, car or home.
WARNING
IF YOU SMELL GAS:
• Shut o gas to the appliance.
• Extinguish any open flame.
• If odor continues, leave the area immediately.
• After leaving the area, call your gas supplier
or fire department.
Failure to follow these instructions could result
in fire or explosion, which could cause property
damage, personal injury or death.
Do not store or use gasoline, or other
flammable vapors and liquids, in the vicinity of
this or any other appliance.
A propane cylinder not connected for use shall
not be stored in the vicinity of this or any other
appliance.
IF THE INFORMATION IN THIS INSTRUCTION MANUAL IS NOT FOLLOWED EXACTLY, A FIRE OR
EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY, OR LOSS OF LIFE.

2www.outdoorrooms.com 42519 REV B: DSI: 06-23-2020
Page | 2 www.outdoorrooms.com BCH-1242 42477 REV B 08-20-18
DANGER:
FLAMMABLE GAS UNDER PRESSURE.
LEAKING LP-GAS MAY CAUSE A FIRE OR EXPLOSION IF IGNITED
CAUSING SERIOUS BODILY INJURY OR DEATH.
CONTACT LP GAS SUPPLIER FOR REPAIRS, OR DISPOSAL OF A
CYLINDER OR UNUSED LP-GAS.
WARNING: FOR OUTDOOR USE ONLY.*
DO NOT USE OR STORE CYLINDER IN A BUILDING,
GARAGE, OR ENCLOSED AREA.
WARNING:
Know the odor of LP-gas. If you hear, see,
or smell leaking LP-gas, immediately get everyone
away from the cylinder and call the Fire Department.
Do not attempt repairs.
Caution your LP-gas supplier to:
Be certain cylinder is purged of trapped
air prior to first filling.
Be certain not to over fill the cylinder.
Be certain cylinder requalification date is
checked.
LP-gas is heavier than air and may settle in low places
while dissipating.
Contact with the liquid contents of cylinder will cause
freeze burns to the skin.
Do not allow children to tamper or play with cylinder.
When not connected for use, keep cylinder valve
turned off. Self-contained appliances shall be limited
to a cylinder of 30 lb. capacity or less.
Do not use, store or transport cylinder where it would
be exposed to high temperatures. Relief valve may
open allowing a large amount of flammable gas to
escape.
When transporting, keep cylinder secured in an
upright position with cylinder valve turned off.
WHEN CONNECTING FOR USE:
Use only in compliance with applicable codes.
Read and follow manufacturer’s instructions.
Consult manufacturer’s instructions concerning the
cylinder connection provided with your appliance.
Be sure the regulator vent is not pointing up.
Turn off all valves on the appliance.
Do not check for gas leaks with a match or open
flame. Apply soapy water at areas marked “X”. Open
cylinder valve. If bubbles appear, close valve and
have LP-gas service person make needed repairs.
Also, check appliance valves and connections to make
sure they do not leak before lighting appliance.
Light appliance(s) following manufacturer’s
instructions.
When appliance is not in use, keep the cylinder valve
closed.
DO NOT REMOVE, DEFACE, OR OBLITERATE THIS LABEL
*EXCEPT AS AUTHORIZED BY ANSI/NFPA 58
DANGER: Do not store a spare LP cylinder under or near a barbecue
grill, or other heat sources. NEVER fill an LP cylinder beyond 80% full: a fire
causing death or serious injury may occur.

3
www.outdoorrooms.com
42519 REV B: DSI: 06-23-2020
1
Additional Warnings
This appliance is a Decorative Outdoor Gas Appliance for
OUTDOOR USE ONLY and MUST NOT be used for cooking.
Install the burner system in an enclosure on a flat and
stable surface in an outdoor location such as a patio or
deck. This location must be adjacent to the gas supply
line or propane gas supply. DO NOT locate the appliance
where it will get excessively wet or submerged in water.
ASPHYXIATION RISK
• This gas appliance is for outdoor use in a
well ventilated space.
• This unit must NOT be installed in an
enclosed structure.
DO NOT USE this appliance if any part has
been underwater. Have an authorized service
technician inspect the appliance and replace
any component in the control system or gas
supply which has been underwater.
• Children and adults should be alerted to the
hazards of high surface temperatures and open
flames and should stay away to avoid burns or
clothing ignition.
• Young children should be carefully
supervised when they are in the area of the
appliance.
• Clothing or other flammable materials should
not be hung from appliance or placed on or
near the appliance.
• Any guard, barrier or other protective device
removed for servicing the appliance shall be
replaced prior to operating the appliance.
The Outdoor GreatRoom CompanyTM, LLC
disclaims any responsibility for, and the
warranty will be voided by, the following actions:
• Installation and use of any damaged
components.
• Modification of the burner assembly.
• Installation other than as detailed in
this manual.
Any such action may result in a fire or
explosion causing property damage,
personal injury, or death.
SHARP EDGES
Wear protective gloves and safety glasses
during installation.
Inspect appliance and components for damage.
Damaged parts may impair safe operation.
Do NOT install damaged, incomplete, or
substitute components.
Report damaged parts to your dealer.
WARNING
!!
WARNING
!!
WARNING
!!
WARNING
!!
WARNING
!!
WARNING
!!
WARNING
Do NOT burn solid fuels in this gas appliance.
!!
WARNING
!!
Installation and repair should be
performed only by a qualified
service person. More frequent
cleaning and maintenance may
be required as necessary. It is
imperative that the burner,
controls, and circulating air
passageways of the appliance
are kept clean.
The Outdoor GreatRoom
CompanyTM, LLC recommends
the use of NFI Certified Gas
Professionals.

4www.outdoorrooms.com 42519 REV B: DSI: 06-23-2020
1. Appliance Information (DSI Burners)
a. Appliance Certification
b. Specifications
2. Getting Started (DSI Burners)
a. Included Items
b. Tools and Supplies Required
c. Inspect the Appliance and Components
3. Appliance Clearance Requirments (DSI Burners)
a. Surrounding Clearances
b. Enclosure Clearances for CFP Models with DSI
c. Enclosure Clearances for BI Models with DSI
4. Enclosure Design Requirements (DSI Burners)
a. Self-Contained Propane Cylinder Installations
b. Hard-Piped Propane Installations
c. Hard-Piped Natural Gas Installations
5. Gas Setup and Information (DSI Burners)
a. Fuel Type
b. Gas Pressure
c. Gas Supply and Connection
d. Leak Check and Line Purge
e. Additional Gas Supply Information
6. Burner Installation (DSI Burners)
a. Self-Contained Propane Cylinder Installations
b. Hard-Piped Propane Installations
c. Hard-Piped Natural Gas Installations
7. Lighting and Operation (DSI Burners)
8. Troubleshooting (DSI Burners)
9. Service and Maintenance (DSI Burners)
a. Regular Maintenance Tasks
b. Cleaning the Appliance
6
8
10
13
16
18
25
26
28
TABLE OF CONTENTS

5
www.outdoorrooms.com
42519 REV B: DSI: 06-23-2020
10. Reference Materials (DSI Burners)
a. Battery Pack Installation and Operation
b. Remote Pairing and Operation
c. Pressure Testing and Verification
d. Standard Wiring Diagram
e. Service Parts
f. Optional Parts
g. Dimensional Information
11. Warranty Information
30
40

6www.outdoorrooms.com 42519 REV B: DSI: 06-23-2020
1
APPLIANCE INFORMATION (DSI BURNERS)
A. APPLIANCE
CERTIFICATION
B. SPECIFICATIONS
MODEL: ALL CRYSTAL FIRE®
PLUS BURNERS & BURNER
INSERTS WITH DIRECT SPARK
IGNITION
TESTING AGENCY: Underwriters
Laboratories (UL LLC)
TYPE: Decorative Gas-Fired
Outdoor Fireplace.
STANDARD: ANSI Z21.97-2017 /
CSA 2.41-2017 Outdoor
Decorative Gas Appliances
The Crystal Fire®Plus burner
series has been tested in
accordance to ANSI Z21.97-2017 /
CSA 2.41-2017 and has been
listed by Underwriters
Laboratories (UL LLC) for
installation and operation as
described in these installation and
operating instructions.
When the appliance is for
connection to a fixed piping
system, the installation must
conform with local codes, or in
the absence of local codes with
National Fuel Gas Code, ANSI
Z223.1 * NFPA 54; National Fuel
Gas Code; Natural Gas and
Propane Installation Code, CSA
B149.1; or Propane Storage and
Handling Code, CSA B149.2, as
applicable.
The appliance, when installed,
must be electrically grounded in
accordance with local codes, or
in the absence of local codes,
with the National Electrical Code,
ANSI/NFPA 70; or the Canadian
Electrical Code, CSA C22.1, if
applicable.
MINIMUM INLET
PRESSURE
MAXIMUM INLET
PRESSURE
IDEAL INLET
PRESSURE
PROPANE NATURAL
GAS PROPANE NATURAL
GAS PROPANE NATURAL
GAS
10.5 in. WC
(2.6 kPa) 4.5 in. WC
(0.87 kPa)
14.0 in. WC
(3.5 kPa)
10.5 in. WC
(2.6 kPa)
11.0 in. WC
(2.7 kPa)
7.0 in. WC
(1.7 kPa)
MODEL ORIFICE SIZE STANDARD INPUT RATE
PROPANE NATURAL
GAS PROPANE NATURAL GAS
CFP20
BI16 #43 #27 55K BTU/hr.
(16.12 kW)
55K BTU/hr.
(16.12 kW)
CFP1224
BI719 #43 #27 55K BTU/hr.
(16.12 kW)
55K BTU/hr.
(16.12 kW)
CFP1242
BI737 #35 #17 80K BTU/hr.
(23.33 kW)
80K BTU/hr.
(23.33 kW)
The burner specifications listed above correspond to the factory standard con-
figuration. Each of the above burners are able to operate at a higher input rate
with a larger flame by purchasing and installing an optional upgrade orifice.
See Maximum Rate information on Pg. 42 and Reference Materials on Pg. 70 for
more information.
Direct Spark Ignition (DSI) burners are ordered fuel-type specific and should not be field converted. Ensure that the
fuel type of your burner matches the intended fuel type available at the installation location.
All Crystal Fire® Plus burners are approved for use in the Commonwealth of
Massachusetts.
Approval Code: P1-0720-468

7
www.outdoorrooms.com
42519 REV B: DSI: 06-23-2020
MODEL ORIFICE SIZE MAXIMUM INPUT RATE
PROPANE NATURAL GAS PROPANE NATURAL GAS
CFP20*
BI16* #36 #17 70K BTU/hr. (20.5 kW) 77.5K BTU/hr. (22.7 kW)
CFP1224*
BI719* #36 #17 75K BTU/hr. (22.0 kW) 75K BTU/hr. (22.0 kW)
CFP1242*
BI737* .125” #5 100K BTU/hr. (29.3 kW) 100K BTU/hr. (29.3 kW)
CFP1264
BI757 .125” #5 100K BTU/hr. (29.3 kW) 100K BTU/hr. (29.3 kW)
CFP12120
BI7114 #36 (X2) #4 (X2) 140K BTU/hr. (41.0 kW) 140K BTU/hr. (41.0 kW)
CFP30
BI28 .125” #5 101K BTU/hr. (29.6 kW) 100K BTU/hr. (29.3 kW)
CFP2424
BI1919 .125” #5 105K BTU/hr. (29.3 kW) 100K BTU/hr. (29.3 kW)
CFP1272
BI766 #43 (X2) #24 (X2) 100K BTU/hr. (20.5 kW) 100K BTU/hr. (29.3 kW)
CFP1284
BI778 #42 (X2) #10 (X2) 120K BTU/hr. (35.2 kW) 120K BTU/hr. (35.2 kW)
CFP1296
BI790 #39 (X2) #7 (X2) 130K BTU/hr. (38.1 kW) 130K BTU/hr. (38.1 kW)
CFP12108
BI7102 #36 (X2) #4 (X2) 140K BTU/hr. (41.0 kW) 140K BTU/hr. (41.0 kW)
MINIMUM INLET
PRESSURE
MAXIMUM INLET
PRESSURE
IDEAL INLET
PRESSURE
PROPANE NATURAL
GAS PROPANE NATURAL
GAS PROPANE NATURAL
GAS
10.5 in. WC
(2.6 kPa)
4.5 in. WC
(0.87 kPa)
14.0 in. WC
(3.5 kPa)
10.5 in. WC
(2.6 kPa)
11.0 in. WC
(2.7 kPa)
7.0 in. WC
(1.7 kPa)
*The burners denoted with an asterisk are not setup standard from the factory to
operate at their maximum gas consumption rate. In order to achieve the maximum
gas consumption rate, an upgraded orifice must be purchased and installed.
See Reference Materials on Pg. 70 for more information.
Direct Spark Ignition (DSI) burners are ordered fuel-type specific and should not be field converted. Ensure that
the fuel type of your burner matches the intended fuel type available at the installation location.

8www.outdoorrooms.com 42519 REV B: DSI: 06-23-2020
2
GETTING STARTED (DSI BURNERS)
A. INCLUDED ITEMS
Crystal Fire® Plus Burner
Direct Spark Ignition (DSI) System
(Connected to burner)
Crystal Fire® Plus Instruction Manual
UL Rating Label (Attached to burner)
Power Adaptor
Standard DSI Control Panel
Emergency Stop Button and Control Panel
(CFP-ESO-CP)
Glass Media
(See table below for number of media bags)
Switch Bypass (CF-DSI-SB)
1.
2.
3.
4.
5.
6.
7.
8.
9.
1
2
3
45
6
7
8
9
MODEL CFP20
BI16
CFP30
BI28
CFP1224
BI719
CFP1242
BI737
CFP1264
BI757
Number of Media Bags 2 5 2 3 4
MODEL CFP1272
BI766
CFP1284
BI778
CFP1296
BI790
CFP12108
BI7102
CF12120
BI7114
Number of Media Bags 5 5 6 7 8
A 10’ propane regulator hose for use with 20 lb. self-contained propane cylinders will be included with
the following burners when ordered for use with propane:
CFP20/BI16, CFP30/BI28, CFP1224/BI719, CFP1242/BI737, and CFP1264/BI757
It is not recommended to operate any burners not listed above on a self-contained propane cylinder
due to potentially dangerous gas capacity issues.

9
www.outdoorrooms.com
42519 REV B: DSI: 06-23-2020
B. TOOLS AND SUPPLIES REQUIRED
C. INSPECT THE APPLIANCE AND COMPONENTS
Work Gloves
Safety Glasses
Utility Knife (for opening packaging)
(2X) Adjustable Wrenches
Corrosion-Free Leak Test Solution
Small Flat-Blade Screwdriver
Digital or Slack-Tube Manometer with ¼” ID
Tube Attachment
GFCI Protected Outlet installed in accordance
with local code. Use weather-proof cover.
The Outdoor GreatRoom Company™ has a
recommended junction box assembly available.
Please see reference materials for more
information. This junction box assembly
MUST BE installed on a GFCI protected circuit.
OPTIONAL: (2X) D-Cell Batteries if using
optional battery pack. See Reference Materials
for more information.
1.
2.
3.
4.
5.
6.
7.
8.
IGNITER/SENSOR
FLEX-LINE
WIRING
BURNER TRIM
What to inspect:
Burner
• Look for bent or dented components.
Plumbing (Stainless steel flex-line)
• Look for cracks and extreme bends or kinks.
Wiring
• Look for cracks and extreme bends or
kinks on aluminum tube.
Igniter/Sensor
• Ensure that electrodes are not loose an
cannot rotate in ceramic insulators.
• Look for extreme bends.
1.
2.
3.
3.
1
2
34
5
67
8

10 www.outdoorrooms.com 42519 REV B: DSI: 06-23-2020
3
APPLIANCE CLEARANCE REQUIREMENTS
(DSI BURNERS)
A. SURROUNDING CLEARANCES
Burner model shown may not be the same model as your burner. Clearance requirement is 72” from top of
burner to any overhead combustible materials and 24” from edge of burner trim to any combustible side
walls. Burner Inserts (BI models) must follow the clearances for their corresponding CFP model.
WARNING
FOR OUTDOOR USE ONLY
!!
WARNING
FIRE RISK
Follow all minimum clearance requirements.
Failure to provide adequate clearance to
combustible materials can result in property
damage or loss of life.
!!
Easy access to appliance control panel.
Easy access to gas connections for service
and maintenance.
Does not restrict walkways around
appliance and enclosure.
Installed on solid and level surface.
Appliance should be installed in an enclosure
in a location that meets the following criteria:
What qualifies an area as an outdoor space?
To qualify as an outdoor space, the area in
which the appliance is installed must be no
more restrictive than the following
configurations:
Walls on all four sides with no overhead cover.
A partial enclosure with an overhead cover
and two side walls. Walls can be parallel to
each other or at right angles to each other.
A partial enclosure that includes an overhead
cover and three side walls where 30 percent of
the surrounding side wall area is permanently
open.
•
•
•
•
•
•
•
24.00
72.00
24.00
72.00
24.00
24.00
All Dimensions are in Inches

11
www.outdoorrooms.com
42519 REV B: DSI: 06-23-2020
B. ENCLOSURE CLEARANCES FOR CFP MODELS WITH DSI
Follow all minimum clearance requirements.
Failure to provide adequate clearance to
combustible materials can result in property
damage or loss of life.
WARNING
!!
Required Clearances to Combustibles
LINEAR MODELS A B C
CFP1224
4 in. 4 in. 12.5 in.
CFP1242
CFP1264
CFP12120
CFP1272
CFP1284
CFP1296
CFP12108
Required Clearances to Combustibles
ROUND MODELS A B C
CFP20 4 in. 4 in. 9 in.
CFP30
A
B
C
C
A
B

12 www.outdoorrooms.com 42519 REV B: DSI: 06-23-2020
B. ENCLOSURE CLEARANCES FOR CFP MODELS WITH DSI
Follow all minimum clearance requirements.
Failure to provide adequate clearance to
combustible materials can result in property
damage or loss of life.
WARNING
!!
Required Clearances to Combustibles
LINEAR MODELS A B C
BI719
7 in. 7 in. 12.5 in.
BI737
BI757
BI7114
BI766
BI778
BI790
BI7102
Required Clearances to Combustibles
ROUND MODELS A B C
BI16 6.75 in. 6.75 in. 12.5 in.
BI28 6 in. 6 in. 12.5 in.
A
B
A
B
C
C

13
www.outdoorrooms.com
42519 REV B: DSI: 06-23-2020
ENCLOSURE DESIGN (DSI BURNERS)
4
A. SELFCONTAINED PROPANE CYLINDER INSTALLATIONS
The Outdoor GreatRoom CompanyTM has vent blocks available for DIY landscape block projects as well as vent plates for
other enclosures. See reference materials for more information.
MINIMUM VENTILATION REQUIREMENTS:
Two (2) openings of equal size on opposite sides of the enclosure. The bottom of these openings
should be within 5 in. of the top of the enclosure and their total open area should be
1 in./lb. of stored propane. (20 in. total for a 20 lb. propane cylinder or 10 in. for each opening).
Two (2) openings of equal size on opposite sides of the enclosure. The top of these openings
should be within 5 in. of the bottom of the enclosure and their total open area should be 1 in./lb.
of stored propane. (20 in. total for a 20 lb. propane cylinder or 10 in. for each opening).
A 1/8 in. rod should be able to be passed through the openings in the vents. No screen or mesh
should be used.
Enclosures built to house a self-contained propane cylinder must have ventilation at the top and
bottom of the enclosure. This allows for quick dissipation of gas in the event of a leak, or in the
event of venting from the tank when over-pressurized. Propane is denser than air and settles in
low places. Ventilation also helps to prevent excessive condensation.
Burner model shown may not be the same model as your burner.
All Dimensions are in Inches
5.00 MAXIMUM
5.00 MAXIMUM
OPENINGS ARE SHOWN AS 5" X 2"
RECTANGLES
GFCI OUTLET WITH
WEATHERPROOF COVER
DRAINAGE TO ELIMINATE
STANDING WATER WITHIN
ENCLOSURE.
A readily accessible GFCI outlet
should be installed within the
enclosure to local electrical
code. A weatherproof cover
should be used.
If outlet will not be readily
accessible, the circuit controlling
the outlet should be wired as a
GFCI circuit and the RESET of
that circuit should be readily
accessible.
In addition to the ventilation
requirements, it is recommended
that a vapor barrier be used on
the interior of the enclosure to
limit condensation.

14 www.outdoorrooms.com 42519 REV B: DSI: 06-23-2020
B. HARDPIPED PROPANE INSTALLATIONS
The Outdoor GreatRoom CompanyTM has vent blocks available for DIY landscape block projects as well as vent plates for
other enclosures. See reference materials for more information.
MINIMUM VENTILATION REQUIREMENTS:
Two (2) openings of equal size on opposite sides of the enclosure. The top of these openings
should be within 5 in. of the bottom of the enclosure and their total open area should be 20 in..
A 1/8 in. rod should be able to be passed through the openings in the vents. No screen or mesh
should be used.
Enclosures built for hard-piped propane installations must have ventilation at the bottom of the
enclosure. This allows for quick dissipation of gas in the event of a leak. Propane is denser than air
and settles in low places. Ventilation also helps to prevent excessive condensation.
Burner model shown may not be the same model as your burner.
All Dimensions are in Inches
5.00 MAXIMUM
OPENINGS ARE SHOWN AS 5" X 2"
RECTANGLES
GFCI OUTLET WITH
WEATHERPROOF COVER
DRAINAGE TO ELIMINATE
STANDING WATER WITHIN
ENCLOSURE.
A readily accessible GFCI outlet
should be installed within the
enclosure to local electrical
code. A weatherproof cover
should be used.
If outlet will not be readily
accessible, the circuit controlling
the outlet should be wired as a
GFCI circuit and the RESET of
that circuit should be readily
accessible.
In addition to the ventilation
requirements, it is recommended
that a vapor barrier be used on
the interior of the enclosure to
limit condensation.

15
www.outdoorrooms.com
42519 REV B: DSI: 06-23-2020
B. HARDPIPED NATURAL GAS CYLINDER INSTALLATIONS
The Outdoor GreatRoom CompanyTM has vent blocks available for DIY landscape block projects as well as vent plates for
other enclosures. See reference materials for more information.
5.00 MAXIMUM
OPENINGS ARE SHOWN AS 5" X 2"
RECTANGLES
GFCI OUTLET WITH
WEATHERPROOF COVER
DRAINAGE TO ELIMINATE
STANDING WATER WITHIN
ENCLOSURE.
Enclosures built for hard-piped natural gas installations must have ventilation near the top of the
enclosure. This allows for quick dissipation of gas in the event of a leak. Natural gas is lighter than
air and rises. Ventilation also helps to prevent excessive condensation.
Burner model shown may not be the same model as your burner.
MINIMUM VENTILATION REQUIREMENTS:
Two (2) openings of equal size on opposite sides of the enclosure. The bottom of these openings
should be within 5 in. of the top of the enclosure and their total open area should be 20 in..
A 1/8 in. rod should be able to be passed through the openings in the vents. No screen or mesh
should be used.
All Dimensions are in Inches
A readily accessible GFCI outlet
should be installed within the
enclosure to local electrical
code. A weatherproof cover
should be used.
If outlet will not be readily
accessible, the circuit controlling
the outlet should be wired as a
GFCI circuit and the RESET of
that circuit should be readily
accessible.
In addition to the ventilation
requirements, it is recommended
that a vapor barrier be used on
the interior of the enclosure to
limit condensation.

16 www.outdoorrooms.com 42519 REV B: DSI: 06-23-2020
GAS SETUP AND INFORMATION (DSI BURNERS)
5
!! WARNING:
FIRE AND EXPLOSION RISK:
VERIFY INLET PRESSURES
• High pressure may cause an over-fire
condition.
• Low pressure may cause delayed ignition
and explosion.
• Minimum pressure must be verified when
ALL household appliances are operating.
AN APPLIANCE REGULATOR MUST BE
INSTALLED UPSTREAM OF THE APPLIANCE
FOR ALL PRESSURES ABOVE 14 IN. WC FOR
LIQUID PROPANE AND ALL PRESSURES
ABOVE 11 IN. WC FOR NATURAL GAS.
A. FUEL TYPE
• Before making any gas connections, ensure the
appliance being install is compatible with the
available gas type.
• All Crystal Fire® Plus burners with Direct Spark
Ignition are ordered fuel type specific and it is
NOT recommended to field convert this
appliances.
B. GAS PRESSURE
• Proper input pressures are required for
optimum performance and safety. Gas line
sizing is EXTREMELY important and should be
performed only by a qualified gas professional.
Supply line sizing requirements need to be made
following ANSI Z223.1/NFPA 54.
C. GAS SUPPLY AND CONNECTION
• All fixed fuel piping (hard-piped) systems shall
be installed in accordance to local building codes;
if none exist, ANSI Z223.1/NFPA 54 should be
followed.
• Installation of fixed fuel piping (hard-piped)
systems should be performed only by authorized
installers approved and/or licensed as required by
the locality.
• A dedicated manual shut-o valve shall be
installed upstream of this appliance and its
controls.
• This appliance and its dedicated manual
shuto valve need to be disconnected from the
main gas supply system during any pressure
testing in excess of ½ psi (3.5 kPa).
• This appliance must be isolated from the main
gas supply by closing its dedicated manual
shuto valve during any pressure testing of the
gas supply system at test pressures equal to or
less than ½ psi (3.5 kPa).
• Pressure requirements for the appliance are
shown in the table below. Pressure readings must
be attained WHILE THIS APPLIANCE AND ALL
OTHER GAS APPLIANCES ARE IN OPERATION.
• Although it is safe to operate at minimum
pressure, the unit should be operating at the
ideal inlet pressure, shown in the table below.
MINIMUM INLET
PRESSURE
MAXIMUM INLET
PRESSURE
IDEAL INLET
PRESSURE
PROPANE NATURAL
GAS PROPANE NATURAL
GAS PROPANE NATURAL
GAS
10.5 in. WC
(2.6 kPa)
4.5 in. WC
(0.87 kPa)
14.0 in. WC
(3.5 kPa)
10.5 in. WC
(2.6 kPa)
11.0 in. WC
(2.7 kPa)
7.0 in. WC
(1.7 kPa)

17
www.outdoorrooms.com
42519 REV B: DSI: 06-23-2020
D. LEAK CHECK AND LINE PURGE
Once the gas piping system is in place, all
fittings and connections need to be checked for
leaks.
Use a commercially-available, non-corrosive
leak check solution.
Once leak test is complete, be sure to rinse o
all remaining leak check solution from the gas
piping systems.
After leak check has been performed and the
gas supply system is leak free, a purge of the air
in the supply line should be performed in order
to ensure a safe first ignition of the appliance.
FIRE RISK
EXPLOSION RISK
• Gas build-up during purge may ignite.
• Purge should be performed by an authorized
gas technician.
• Eliminate possible ignition sources such as
open flames and sparks during leak check.
• Ensure adequate ventilation.
E. ADDITIONAL GAS SUPPLY
INFORMATION
For propane installations using a non-disposable,
self-contained propane supply system (20 lb.
propane tank and the manufacturer supplied
regulator hose):
• The propane cylinder use with this
appliance must be constructed and
marked in accordance with the U.S.
Department of Transportation. (D.O.T.)
Specifications for Propane-Gas Cylinders,
or the Standard for Cylinders, Spheres
and Tubes for Transportation of Dan-
gerous Goods and Commission, CAN/
CSA-B339, as applicable.
• The propane cylinder must be provided
with a listed overfilling prevention device
(OPD).
• The propane cylinder must be
compatible with the regulator hose
supplied by the manufacturer with this
appliance.
Improper installation, adjustment, alteration,
service or maintenance can cause injury or
property damage. Read the installation,
operating, and maintenance instructions
thoroughly before installing or servicing this
equipment.
FIRE RISK
EXPLOSION RISK
ASPHYXIATION RISK
• Check all fittings and connections.
• Do not use an open flame.
• Eliminate possible ignition sources such as
open flames and sparks during leak check.
• Presence of gas leaks can lead to high levels
of carbon monoxide. If leaks are detected,
ensure proper ventilation is available to
expedite the dissipation of leaked gas.
WARNING: CHECK FOR GAS LEAKS
!!
WARNING
!!
Installation and repair should be performed
only by a qualified service technician.
WARNING
!!
WARNING
!!

18 www.outdoorrooms.com 42519 REV B: DSI: 06-23-2020
BURNER INSTALLATION (DSI BURNERS)
6
A. SELFCONTAINED PROPANE
CYLINDER INSTALLATIONS
Secure supplied control panel to enclosure with
suitable fasteners. See Image 16.1. If burner is
being installed in an Outdoor GreatRoom
CompanyTM fire table, the control panel and switch
will already be installed.
If controls other than the standard control panel
are being used, refer to 42511 Crystal Fire ®Plus
Supplemental Commercial Manual.
Connect supplied power adaptor to GFCI outlet
installed within enclosure. See image 16.2.
If optional battery pack (CF-DSI-BP) is being used,
see Reference Materials for more information.
1.
2.
(Img. 16.1)
WARNING
!!
Installation and repair should be performed
only by a qualified service technician.
(Img. 16.2)
IMPORTANT
Other media options apart from the supplied
clear glass gems can be used in Crystal Fire®
Plus burners, but they should be supplied
by the Outdoor GreatRoom CompanyTM. This
ensures that the proper amount of media is
used and that the media is approved for use in
gas appliances.
MEDIA MUST BE IN PLACE DURING
OPERATION. Operation of appliance without
media will damage the burner.
Overfilling of the burner with media can cause
adverse operational issues.
Use of burner media other than that supplied
by The Outdoor GreatRoom CompanyTM is not
recommended and could lead to operational
issues.

19
www.outdoorrooms.com
42519 REV B: DSI: 06-23-2020
With burner sitting on top of enclosure, connect
control switch to DSI system. The connector is
keyed and will only connect one way. See Image
16.3. It may be necessary to prop up burner in one
or more locations.
With burner in same position as in Step 3, connect
power adaptor to DSI system. The connections will
be labelled 3.3 VDC + and 3.3 VDC – on both the
DSI system and power adaptor. If they are not
connected properly, the unit will not operate.
See Image 16.4.
Using adjustable wrenches, tighten all connections
shown in Image 16.5. This step serves as a final
safety measure as all fittings come tightened from
the factory.
Carefully place burner assembly into enclosure
DO NOT USE IGNITION ELECTRODES AS A
HANDLE. Evenly spread included glass media over
burner surface. Glass media MUST be
present inside ignition wind guard. Place 38-42
OGC standard glass beads within the wind guard.
Media SHOULD NOT contact the ignition
electrodes. See Image 16.6.
If using media other than the included standard
glass beads, one layer of media within the ignition
wind guard is sucient keeping in mind that
media CANNOT be in contact with ignition
electrodes.
3.
4.
5.
6.
(Img. 16.3)
(Img. 16.4)
(Img. 16.5)
(Img. 16.6)
OUTLET CONNECTION
FROM DSI TO BURNER
CONNECTION FROM
FLEX-LINE TO ORIFICE
INLET CONNECTION
FROM REGULATOR HOSE
TO DSI SYSTEM
BURNER SURFACE
IGNITION WIND GUARD
IGNITION ELECTRODES

20 www.outdoorrooms.com 42519 REV B: DSI: 06-23-2020
Turn control switch to ON position to verify pres-
ence of power and spark location. Look inside ig-
nition wind guard for visible spark. See Image 16.7.
After spark is confirmed, turn control switch back
to OFF position.
Ensure propane cylinder valve is closed.
Hand-tighten propane regulator hose to propane
cylinder. See Image 16.8.
Verify that control switch is in the OFF position.
Apply commercially-available, non-corrosive leak
check solution to all gas connection points. See
Image 16.9. Slowly open valve on propane
cylinder and check for any bubbles on inlet side
of gas system. A small amount of gas will purge
through DSI valve. This is normal. If bubbles are
present at inlet fittings, close propane cylinder
valve immediately and tighten all fittings again
using adjustable wrenches.
If no leaks are present, a first lighting and final leak
check can be performed. With propane cylinder
open, turn control switch to the ON position. The
appliance will automatically spark and ignite.
Verify no bubbles are present on the outlet side of
the gas system. See Image 16.10.
If no leaks are present on outlet side of gas
system, the Crystal Fire* Plus burner with DSI
system is ready for normal operation. If leaks are
present, turn control switch OFF position, close
propane cylinder valve, and re-tighten all fittings.
Repeat steps 9-10.
ON
OFF
REMOTE
SPARK LOCATION
(Img. 16.7)
BURNER FLEX-LINE
AND ORIFICE CONNECTION
(OUTLET SIDE)
PROPANE TANK AND
REGULATOR HOSE
CONNECTION
(INLET SIDE)
REGULATOR HOSE
AND VALVE CONNECTION
(INLET SIDE)
BURNER FLEX-LINE
AND VALVE CONNECTION
(OUTLET SIDE)
(Img. 16.8)
(Img. 16.9-16.10)
OUTLET CONNECTION
FROM DSI TO BURNER
CONNECTION FROM
FLEX-LINE TO ORIFICE
INLET CONNECTION
FROM REGULATOR HOSE
TO DSI SYSTEM
7.
8.
9.
10.
11.
Other manuals for Crystal Fire Plus
1
Table of contents
Other Outdoor GreatRoom Company Fireplace Accessories manuals
Popular Fireplace Accessories manuals by other brands

Valor
Valor PORTRAIT BSK563 installation instructions

HPC
HPC El Pilot Assembly Replacement

Hearth & Home
Hearth & Home 6000C-IFT installation instructions

Napoleon
Napoleon GS831C installation instructions

kozy heat
kozy heat NCK-C39-D quick start guide

Heatilator
Heatilator DF-SAL60-PT installation instructions

Valor
Valor 1595CFKV2 Installation & operating instructions

Montigo
Montigo H38-DF Installing

Eureka
Eureka 215237 installation instructions

Enclume
Enclume COUNTRY HOME FIREPLACE TOOL STAND FPTS2 Assembly and installation instructions

Travis Industries
Travis Industries 94700881 quick start guide

Regency
Regency Heatwave P36 Installation