
8
GAS REQUIREMENTS
LIQUID PROPANE
Your Outdoor Plus re pit is not provided with a
propane tank. You will need to provide one. Use these
specication for purchasing your propane tank:
SPECIFICATIONS
The 20 lb propane gas supply cylinder is constructed
and marked in accordance with the specications
for propane gas cylinders as required by the U.S.
Department of Transportation (DOT), Specications for
LP-Gas Cylinders, or the Standard for Cylinders, Spheres
and Tubes for Transportation of Dangerous Goods and
Commission, CAN/CSA B339, as applicable.
Manifold Pressure: For plumbed-in liquid propane
installation, use a regulator.
Supply Pressure:
Natural Gas:
Minimum 3.5” W.C. / 1/8 PSI
Nominal 7.0" W.C. / 1/4 PSI
Maximum 14.0” W.C. / 1/2 PSI
Liquid Propane:
Minimum 8.0” W.C. / 1/3 PSI
Nominal 11.0" W.C. / 1/2 PSI
Maximum 14.0” W.C. / 1/2 PSI
Pressure Regulator: The unit must be used with the
supplied gas pressure regulator and hose assembly.
The regulator will control and maintain a uniform gas
pressure in the manifold. The burner orifice has been
sized for the gas pressure delivered by the regulator.
Replacement pressure regulator and hose assemblies
must be those specified in this manual.
Cylinder Specification: Any propane gas supply cylinder
used with this fire pit must be approximately 12 inches in
diameter and 18 inches high. The maximum fuel capacity
is 20 lbs. of propane, or 5 gallons. Full cylinder weight
should be approximately 38 lbs. (43.7 lbs. nominal water
capacity.) Always use the cylinder dust cap on the cylinder
valve outlet during transport and when the cylinder is not
connected to the fire pit. The 20 lb propane gas cylinder
used must include a collar to protect the cylinder valve.
Filler Valve: If you do not have an updated filler valve on
your existing propane tank, you will need to purchase one
at your local hardware store, as you will not be allowed to
refill the tank at any filling station.
NATURAL GAS
Ensure that the service supplying the re pit is tted
with a conveniently positioned shut o valve with easy
access. The shut o valve MUST NOT be inside the
appliance!
REQUIREMENTS
Always check the rating plate to make sure the gas
supply you are hooking up to is the gas type the re pit
is manufactured for.
The installation of this appliance must conform with
local codes or, in the absence of local codes, to the
National Fuel Gas Code, ANSI Z223.1, NFPA 54; National
Fuel Gas Code; Natural Gas and Propane Installation
Code, CSA B149.1; or Propane Storage and Handling
Code, CSA B146.2, as applicable. Natural gas connection
must be performed by a licensed contractor or local gas
company representative.
Ensure that the service supplying the re pit is tted
with a conveniently positioned shut o valve with easy
access.
PRESSURE TESTING
If this re pit is installed with a xed fuel piping
system and equipped with an appliance gas
pressure regulator, the re pit and its individual
shuto valve must be disconnected from the gas
supply piping system during any pressure testing
of the system at test pressures in excess of 1/2 psi
The re pit must be isolated from the gas supply
piping system by closing its individual manual
shuto valve during any pressure testing of the
gas supply piping system at test pressures equal
to or less than 1/2 psi
Fire pit Manual