
https://www.overlandtandberg.com
©2022 Overland-Tandberg
10401048-003 RMN-A-01-16
Assign a Static IP Address
If DHCP support is not enabled, set a static IP address for the unit:
CAUTION: Make sure the USB stick file name
network.conf
is all
lowercase letters.
1. Create a file on a USB stick named “
network.conf
” with these
entries:
BOND0_IP4_CONFIG=static
BOND0_IP4_ADDR=nnn.nnn.nnn.nnn
BOND0_IP4_GW=nnn.nnn.nnn.nnn
BOND0_IP4_PREFIX=nn
Replace the variables (“n”) with your desired IP address, gateway,
and prefix as required. For example:
BOND0_IP4_CONFIG=static
BOND0_IP4_ADDR=192.168.10.111
BOND0_IP4_GW=192.168.10.1
BOND0_IP4_PREFIX=24
2. Insert the stick in the USB port on the front of the unit and wait at
least two minutes for the
network.conf
file to update.
3. Remove the USB stick from the front port.
The unit will restart with the updated network settings.
NOTE: If the unit does not reboot automatically, recheck network.conf
filename to ensure it is all lowercase letters.
You may need to use a Linux or MacOS host system to check a filename as
Windows OS can change the filename to uppercase but cannot display it.
The Remote Management Console should now be available at the
static IP address selected. For more information on how to configure
IP addresses, refer to the RDX QuikStation 4 & 8 Product Manual.
Connect to the Remote Management Console
Use a web browser to connect to the Remote Management Console
(RMC) of the RDX QuikStation 8 from any computer on the same
network. Supported operating systems include Microsoft Windows,
Linux, and Apple MacOS.
To connect to the RMC:
1. Obtain the unit’s IP address.
2. On a network host, type the RDX QuikStation IP address in a web
browser’s URL field (for example, “
192.168.10.111
”).
3. Using the default username and password, sign in to the Console.
The default username/password is “
Admin/Admin!
”.
NOTE: Passwords are case-sensitive and should be changed regularly.
Step 6
Configure the RDX QuikStation 8
You can configure your RDX QuikStation 8 as RDX Disks (default) or
RDX Logical Volume (see the RDX QuikStation 4 & 8 Product Manual).
1. Using the RMC, select the device type from the dialog window.
2. Click
OK
.
The system restarts. When done, your selected device configuration
is shown.
NOTE: If you have any RDX cartridges loaded into the RDX QuikStation, the
system will eject the cartridges when it restarts.
Step 7
Connect to iSCSI Targets
In iSCSI terminology, a host computer is referred to as an initiator and
the storage device it connects to as the target.
NOTE: The RDX QuikStation and the host computers must reside on the same
network.
To establish an iSCSI connection in Windows Server:
1. Open the Microsoft iSCSI Initiator and click the
Discovery
tab.
2. Click
Discover Portal
to enter the IP address for the QuikStation 8.
3. Click
OK
.
4. Click the
Targets
tab.
5. Select the target you want to connect to and click
Connect
.
For more information on how to connect to targets, refer to the RDX
QuikStation 4 & 8 Product Manual and your OS documentation.
Prepare for and Perform a Backup
1. If needed, install an approved backup application. Check the
Software Compatibility Matrix using the link available at the top of
the Overview page on Overland-Tandberg Knowledge Base.
2. Launch and configure the backup application software.
For questions regarding software installation, configuration, and
operation, refer to your backup software product documentation or
contact your software provider.
Step 8
For product information, support, and documentation, visit our website:
https://www.overlandtandberg.com
Additional RDX Cartridges
To purchase RDX media cartridges, contact your Overland-Tandberg
Partner or go to our website listed above.
Warranty and Technical Support
For warranty and technical support information, use the Support tab
on our website listed above.
User Guides and Articles
For detailed information on configuring your RDX QuikStation 8, refer
to the RDX QuikStation 4 and 8 Product Manual. The product manual,
quick start guide, and other knowledge base articles are available at:
https://www.overlandtandberg.com/knowledgebase
Product Information
Product name: RDX QuikStation 8
Model/Type Reference: RMN-A-01-16
Manufacturer: Tandberg Data GmbH / Overland-Tandberg
European Regulatory Address:
Tandberg Data GmbH, Nikolaus-Groß-Straße 13, 44329
Dortmund, Germany
Power Ratings
Safety Precautions
CAUTION: Be aware of the location of the power ON/OFF switch on
the front of the RDX QuikStation 8 chassis as well as the room’s
emergency power-off switch, disconnection switch, or electrical outlet
used. If an electrical accident occurs, you can then quickly remove power from
the system.
The rack version of the RDX QuikStation 8 is intended for use when mounted
in a standard rack. It may be used on a shelf or table top as long as the area
is free of clutter to ensure proper ventilation.
The unit is intended for indoor use only. Use an appropriate power supply cord
with a grounded plug and a grounded electrical outlet. The outlet must be
near the equipment and easily accessible.
FCC Compliance Notice
This equipment has been tested and found to comply
with the limits for a Class A digital device, pursuant to part
15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference when
the equipment is operated in a commercial environment.
This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area is likely
to cause harmful interference in which case the user will be required to
correct the interference at his own expense.
Environment Friendly Disposal
You can help protect the environment!
Please remember to respect the local regulations and
hand in the non-working electrical equipments to an
appropriate waste disposal center. The packaging
material is recyclable. Dispose of the packaging in an
environmentally friendly manner and make it available
for the recyclable material collection-service.
Input Voltage 100 - 240 VAC
Input Rated Current 2.0-1.0A
Rated Input Frequency 50-60 HZ