Metal case(optional)
HDS2062M
60MHz
HDS1022M
Average>16:±(5% reading+0.05div) for
△V
+,-,×,÷
20MHz
±3degrees
Unavailable
Electronic circuit debugging Circuit testing Design and manufacture
Education and training Automobile maintenance and testing
Application
Accessories
Probe Multimeter lead Small capacitance
module
CD-Rom USB
Adapter Soft bag
Probe adjust
Current extend
module
Multimeter Specifications
HDS1021M
Average>16:±(3% reading+0.05div) for
△V
Edge, Video
Auto, Normal, Single
±3divisions from screen center
Vpp,Vavg,RMS,Frequency,Period,Vmax,Vmin,Vtop,Vbase,Width,Overshoot,Pre-shoot,Rise time,
Fall time,+Width,-Width,+Duty,-Duty,Delay A B ,Delay A B
Unavailable
4 waveforms
Unavailable
Unavailable
USB
Available
100V-240V AC, 50/60Hz
7.4V, 3500mAh
Model
DC accuracy(Average)
Trigger type
Trigger mode
Trigger level
Automatic measurement
Waveform math
Waveform storage
Lissajou's figure
Communication interface
Cymometer
Power supply
Li-ion battery
Full scale reading
Input Impedance
Capacitance
Voltage
Current
Impedance
Bandwidth
Phase difference
3 digits (Max.4000-count)
10M Ω
51.2nF-100uF:±(3%±3 digit)
VDC:400mV,4V, 400V: ±(1±1digit) Max.input:DC 1000V, VAC:4V,40V,400V:±(1±3digit)
Frequency:40Hz-400Hz, Max:input:AC 750V(virtual value)
DCA:40mA, 400mA:±(1.5%±1 digit) 20A:±(3%± 3 digit)
DAA:40mA±(1.5%±3digit) 400mA:±(2±1digit) 20A:±(3%±3digit)
400 Ω
:±(1%±3digit), 4KΩ~10MΩ(±1±1digit)
4
30V-1.5V
<50(±30) beeping
Diode
On/Off measurement
OWON continues to improve products and reserves the rights to change specifications without advance notice. For latest ones,please refer to our website.