P3 International P0270 User manual

Mold Alert
........................................................
Operation Manual
P0270

Congratulations on your purchase of the P0270 Mold Alert!
Mold is as old as the Earth and it’s everywhere. Under the right set of
conditions, it can actually start to grow inside your home. Some types
of mold even contain mycotoxins (toxins produced by fungus-type
organisms) which can be hazardous to your health.
Mold can grow at humidity levels over 65%. If you keep the relative
humidity in your home below 50%, mold growth can be inhibited. The
Mold Alert Thermo-Hygrometer allows you to monitor some of the key
factors in the home that can lead to mold, dust mites, and bacteria.
INTRODUCTION
FEATURES
● AudibleandVisualalarmfunctiontoindicateriskofmold
● RoomTemperature
● IndoorRelativeAirHumidity
● DewPoint
● MaximumandMinimumvalues
● On/Offswitchforaudioalarm
OVERVIEW
The interaction of temperature and air humidity:
Cold air absorbs little or no moisture. When this air enters living areas
it becomes warmer and can then absorb much more water vapor. This
interdependency of temperature and relative humidity is expressed by
means of the dew-point.
If the measuring unit indicates an air temperature of 68°F and a
relative humidity of 65%, then the dew-point temperature will be 56°F.
What does this mean? That the air, in your bedroom for instance, will
condense and form water droplets on surfaces that are cooler than
56°F, and these damp areas may lead to mold.

STARTUP
OVERVIEW
If the air is at a relative humidity of 40%, then the dew-point
temperature is only 43°F. The walls and ceilings would therefore have
tobesignicantlycolderfortheairtoreachitsdew-pointandforwater
droplets to form.
How to achieve the correct temperature and air humidity:
Tips for active heating and ventilation:
● Checkthedew-point!Surfacesofwallsshouldnotfallbelowa
temperature of 59°F.
● Avoidshuttingofftheheatcompletelywhenleavingthehousefor
extended periods of time.
● Ventilateinallweatherconditions,evenifit’sraining.
● Openthewindowsforashorttimetoairtheroom.Apartially
opened window does not have the desired effect, wastes heating
energy and can even promote the formation of mold.
● Iftheroomairistoodry,particularlyinthewinter,thenelectrical
airhumidiersarerecommended,sinceairingatlowtemperatures
will tend to decrease the humidity further.
● Whenairingaroom,afewminutesshouldbesufcient.Check
the value indicated on your Mold Alert thermo-hygrometer.
1. Select°F/°Candplacetheaudioalarmswitchonthebackofthe
unit in “on” mode.
2. Slideofffrontcompartmentandinstall2batteries1.5VAA.Once
these are in place, the frowning face on the display will light up
brieyandthealarmwillsoundfor2seconds.
3. Replacebatterycompartmentcover.
4. Removetheprotectionlmonthedisplay.
5. The unit is now ready to use.

SET UP
READING THE DISPLAY
Suggestions for Placement of the Unit
There is an opening on the back of the unit, which allows it to be easily
hung from the wall. In addition, a base is provided for the unit to be
placed on any surface in a standing position.
Since the humidity level within rooms can vary greatly, the Mold
Alert should be placed in an area most likely subject to mold growth.
Problem areas are often basements, closets, surfaces near windows
and exterior walls. Anywhere in a home that is damp or has suffered
from water damage is also a prime location for mold growth.
Three values of measurement are displayed simultaneously.
The left column shows the indoor relative humidity (%), the middle
columnindicatesroomtemperature(°C/°F),andtherightcolumn
displays the dew point (Td).
The temperature can be displayed either in Fahrenheit or Celsius by
adjustingthe°C/°Fswitchonthebackoftheunit.Theaudioalarmcan
beactivatedusingthe“AlOn/AlOff”switchonthebackoftheunit.
Riskofmoldformationoccursathumiditylevelsexceeding65%.When
this point is reached, the frowning face icon on the display will light up.
If the audio alarm is activated, it will also sound. An arrow pointing up
willbeashingnexttotherelativehumiditydisplay.Theaudioalarm
can be silenced by pressing any button.
When humidity levels are reduced below 65% the frowning face icon
willstopashingandthealarm(ifactivated)willbesilenced.Thearrow
pointing up display will persist to indicate high humidity levels have
occured in the past. The arrow pointing up display can be reset by
pressing any button.

Minimum/Maximum Temperatures
● Thehighesttemperatureandhumidityvaluessincethelastreset
canbedisplayedbypressingtheMin/Maxbuttonontherightside
of the Mold Alert.
● Thelowesttemperatureandhumiditylevelssincethelastreset,
canbedisplayedbypressingtheMin/Maxbuttonasecondtime.
● ThecurrentvaluescanbeshownagainbypressingtheMin/Max
button a third time.
● TheresetkeyislocatedabovetheMin/Maxbuttonontheright
sideoftheunitandisusedtoresetMin/Maxvalueswhenthey
are displayed.
If humidity levels are high
● Tolowerhumidity,youcanopenwindowsorputafaninthearea
to better ventilate it, which may prevent mold growth.
● Ifthereismoistureorawaterleak,moldgrowthmayhave
occurred. This mold can cause health problems and the sooner
you detect it, the more likely you are to be able to control it.
● Ifyoususpectthatyouhaveamoldproblem,andtheremedies
outlinedinthismanualprovetobeinsufcient,pleasecontacta
mold control professional.
If humidity levels are low enough
The area in which you have placed the unit is safe from mold growth,
however the Mold Alert thermo-hygrometer is a useful product to have
in any home due to its accurate measurements of temperature, dew
point, and humidity.
MAINTENANCE
● DonotexposetheMoldAlerttoextremetemperatures,vibration,
or shock.
● Cleantheunitwithasoftdampcloth.Donotusesolventsor
scouring agents.
● Replacebatteriesiftheunitstopsworking.

SPECIFICATIONS
Model: P0270
RelativeHumidity: 1%to99%RH,accuracy±5%
RoomTemperature: 14°Fto140°F,accuracy±1%
AlarmTriggerPoint: 65%humiditytriggersaudio/visualalarm
Display: UserselectableF°orC°,Min/Maxvalues
Batteries: 2 x AA (not included)
Weight: 4.8 oz.
Dimensions: 33/4"Hx33/4"Wx21/2"D
(Specicationssubjecttochangewithoutnotice)
The Swiss precision hygroTECH sensor allows our Mold Alert to give
accurate measurements when checking a room’s ambient condition.


P3 INTERNATIONAL CORPORATION
LIMITED WARRANTY
P3 INTERNATIONAL CORPORATION (“P3”) warrants to the original retail purchaser
only, that its product is free from defects in material or workmanship under the condition
of normal use and service for a period of six (6) months from the date of purchase. In
the event that a defect, malfunction or failure occurs or is discovered during the warranty
period, P3 will repair or replace at its option the product or component part(s) which shall
appearinthereasonablejudgmentofP3tobedefectiveornottofactoryspecications.
A product requiring service is to be returned to P3 along with the sales receipt or other
proof of purchase acceptable to P3 and a statement describing the defect or malfunction.
All transportation costs shall be borne by the owner and the risk of loss shall be upon the
party initiating the transportation. All items repaired or replaced thereunder shall be sub-
jected to the same limited warranty for a period of six (6) months from the day P3 ships
the repaired or replaced product. The warranty does not apply to any product that has
been subject to misuse, tampering, neglect, or accident or as a result of unauthorized
alterations or repairs to the product. This warranty is void if the serial number (if any) has
been removed, altered, or defaced. This warranty is in lieu of all warranties expressed
orimplied,includingtheimpliedwarrantiesofmerchantabilityandtnessforaparticular
purpose which are expressly excluded or disclaimed. P3 shall not be responsible for
consequential, incidental or other damages, and P3 expressly excludes and disclaims
liability for any damages resulting from the use, operation, improper application, mal-
function or defeat of any P3 product covered by this limited warranty. P3’s obligation is
strictly and exclusively limited to the replacement or repair of any defective product or
component part(s). Some states do not allow the exclusion or limitation of incidental or
consequential damages, so the above limitation or exclusion may not apply to you. P3
does not assume or authorize anyone to assume for it any other obligation whatsoever.
Some states do not allow limitation on how long an implied warranty lasts, so the above
limitationsmaynotapplytoyou.Itistheowner/user'sresponsibilitytocomplywithlocal,
state, or federal regulations, if any, that may pertain to P3 products or their use. This
warrantygivesyouspeciclegalrights,andyoumayalsohaveotherrightswhichvary
from state to state.
If you experience difculty in the operation of your unit, or if your unit requires repair
please contact:
P3INTERNATIONALCORPORATION
TECHNICALSUPPORT
Tel: 212-741-7289
Fax: 212-741-2288
Email: [email protected]
Rev.1007
© 2007 P3 International Corporation
Table of contents
Other P3 International Thermometer manuals

P3 International
P3 International E9310 User manual

P3 International
P3 International E9310 User manual

P3 International
P3 International P0250 User manual

P3 International
P3 International P7680 User manual

P3 International
P3 International P0250 User manual

P3 International
P3 International Sol-Mate P7680 User manual