040706-44 ESTEEM_CM 3
CAUTION
FOR YOUR SAFETY - Do not install or operate your Pacic Energy
replace without rst reading and understanding this manual. Any
installation or operational deviation from the following instructions
voids the Pacic Energy Warranty and may prove hazardous.
This appliance and its individual shutoff valve must be disconnected
from gas supply piping system during any pressure testing of that
system at test pressures in excess of 1/2 psig (3.5 kPa).
This appliance must be isolated from the gas supply piping system
by closing its individual manual shutoff valve during any pressure
testing of the gas supply piping system at test pressures equal to or
less than 1/2 psig (3.5 kPa).
Note: When lit for the rst time, the appliance will emit a slight odour
for a couple of hours. This is due to the curing of paints, sealants
and lubricants used in the manufacturing process. This condition is
temporary. Open doors and windows to ventilate area. Smoke and
fumes caused by the curing process may cause discomfort to some
individuals.
SAFETY
Due to high temperatures, this gas appliance should be located
out of trafc and away from furniture and draperies.
Children and adults should be alerted to the hazards of high
surface temperatures and should stay away to avoid burns or
clothing ignition.
Young children should be carefully supervised when they
are in the same room as the appliance.
Clothing or other ammable material should not be placed
on or near the appliance.
Any grill, panel or door removed for servicing the unit must
be replaced prior to operating. Failure to do so may create a
hazardous condition.
Installation and repair should be done by a qualied service
person. The appliance should be inspected before use and at
least annually by a professional service person. More frequent
cleaning may be required due to excessive lint from carpeting,
bedding material, etc. It is imperative that control compartments,
burners and circulating air passageways of the appliance be
kept clean.
It is Pacic Energy’s policy that no responsibility is assumed
by the Company or by any of its employees or representatives
for any damages caused by an inoperable, inadequate, or unsafe
condition which is the result, either directly or indirectly, of any
improper operation or installation procedures.
Fig. # 1
MAINTENANCE
Caution: Turn off gas and electrical power supply and allow ample
time for unit to cool before servicing appliance. It is recommended
that this appliance and venting should be inspected at least once a
year by a qualied service person.
Do not use this heater if any part has been under water. Immediately
call a qualied service technician to inspect the heater and to replace
any part of the control system and any gas control which has been
under water.
Glass Panel:
Warning: Do not operate appliance with glass panel removed,
cracked or broken. Replacement of the glass panel should be done
by a licensed or qualied service person.
Do not strike or otherwise impact the glass in anyway that may cause it
to break. If the glass becomes cracked or broken, it must be replaced
before using the replace. Replacement glass can be obtained from
your nearest Pacic Energy dealer. The size required is 17 1/8" x
28 1/4" x 5mm. Use ceramic glass only. Do not substitute with
any other type.
To remove broken glass, fold down the front bottom louver to access
the window latches.
Disengage the over-center latches by pulling each lever down and
forward. Grasp the sides of the frame and swing the bottom out to
clear. Lift up and forward to disengage from the top. Remove all
particles of glass. Be careful as they are very sharp. Install new glass
complete with gasket. Replace frame and screws.
Annual Inspection:
a) Clean louvers and air passage ways of excessive lint buildup
from carpeting, bedding material, etc. The ow of combustion and
ventilation air must not be obstructed.
b) Remove glass panel and log set. Inspect logs and burner assembly
for lint and soot buildup. If excessive buildup of soot is present,
have a qualied service person inspect and adjust unit for proper
combustion. Clean logs and burner with a vacuum cleaner, paying
close attention to burner ports.
c) Check the pilot system for proper ame size and operation. (See
Fig. #1) Clean pilot free of lint and dust.
d) Check that the vent pipe and vent terminal are open and free from
blockage or debris. If the venting is disassembled for cleaning, it must
be properly assembled and resealed. Refer to VENTING section for
proper procedure.
e) Check glass panel gasket, replace if necessary. It is important
that the glass seal be maintained in good condition
Note: The appliance area must be kept clear and free from combustible
materials, gasoline and other ammable vapours and liquids.
Periodically:
a) Viewing glass may be cleaned with replace glass cleaner.
b) Exterior nish may be cleaned with mild soap and water.
Caution:
- do not use abrasive cleaners on glass or any other part of the
replace.
- do not clean glass when hot.
THERMOCOUPLE
PILOT FLAME
ELECTRODE
fire-parts.com