FAYb Laser Marker LP-S500W SERIES
5
SPECIFICATIONS
Notes: 1) Work distance reference position represents the calculated center position of the work distance range. Depending on objects to be marked, optimal
distance may vary.
2) Work distance range represents the congurable work distance. Depending on objects to be marked, optimal distance or markable range may vary.
3) This output is measured at the work end. (The preset power is 100.)
4) China models are available,too. Please contact our sales ofce.
5) Microsoft and Windows are trademarks or registered trademarks of Microsoft Corporation in the United States and other countries.
Model No.
Item
CE marking directive compliance
Work distance reference position (Note 1)
Work distance range (Note 2)
Marking laser
Guide laser / pointer
Marking range
Scanning method
Character settings
(character height, width)
Class 4 Yb fiber laser; wavelength: 1,070 nm 0.042 mil
Class 2 semiconductor laser; wavelength: 655 nm 0.026 mil
Code 39, Code 128, ITF, NW-7, JAN (EAN)/ UPC, RSS-14 (GS1 DataBar), RSS (GS1 DataBar)Limited, RSS (GS1 DataBar)Expanded
QR Code, Micro QR Code, Data Matrix, GS1 Data Matrix
RSS-14 (GS1 DataBar)CC-A, RSS (GS1 DataBar)Stacked CC-A, RSS (GS1 DataBar)Limited CC-A, UCC / EAN COMPO
SITE etc.
Input terminal, Output terminal, I/O connector
RS-232C, Ethernet
Head: Naturally air cooling, Controller: Forced air cooling
90-132 V AC, or 180-264 V AC (Auto-switching), 50/60 Hz
470 VA or less (100 V AC), 650 VA or less (200 V AC)
Head: IP67G (Excluding the controller)
0 to +40 °C +32 to +104 °F (Controller, Head)(No dew condensation or icing allowed)
−10 to +60 °C +14 to +140 °F (Controller, Head) (No dew condensation or icing allowed)
35 % to 85 % RH (Controller, Head)(No dew condensation or icing allowed)
FDA regulations, CE marking (Note 4)
Head
Controller
Arced output: −180° to +180° (configurable in 0.01° steps)
Barcodes
2D codes
Composite codes
I/O
Interface
Cooling method
Power supply
Power consumption
Protection degree
Ambient temperature
Storage ambient temperature
Ambient humidity
Applicable standards
Marking spacing
(character spacing, line pitch)
173 to 213 mm 6.811 to 8.385 in
42 W (±5 %) CW oscillation
Low Voltage Directive, EMC Directive, RoHS Directive
327 to 387 mm 12.874 to 15.236 in
193 mm 7.598 in 357 mm 14.055 in
6.5 kg approx. 7.0 kg approx.
24 kg approx. 24 kg approx.
90 × 90 mm 3.543 × 3.543 in 160 × 160 mm 6.299 × 6.299 in
0.1 to 90 mm 0.004 to 3.543 in
(configurable in 0.001 mm 0.0004 in steps)
0.1 to 160 mm 0.004 to 6.299 in
(configurable in 0.001 mm 0.0004 in steps)
0 to 90 mm 0 to 3.543 in
(configurable in 0.001 mm 0.0004 in steps)
0 to 160 mm 0 to 6.299 in
(configurable in 0.001 mm 0.0004 in steps)
Galvano scanning method
LP-S500W
(Marking range 90 × 90 mm 3.543 × 3.543 in)
LP-S505W
(Marking range 160 × 160 mm 6.299 × 6.299 in)
Net weight
Average output (Note 3)
English uppercase letters, English lowercase letters, numerals, katakana, hiragana, kanji (JIS No. 1 and No. 2 standards),
symbols, user-registered characters (up to 50)
Straight Line, Propotional, Justify, Arc
Marking shape
Character types
Laser Marker Utility OS (Note 5) Microsoft Windows®10 Professional (32-bit / 64-bit) / 8 Professional (32-bit / 64-bit) / 7 Professional (32-bit / 64-bit) /
Vista Business (32-bit) / XP Professional (32-bit)
[Dust-, water- and oil-proof performance]
• The head of the FAYb Laser Marker (excluding controller) offers dust- and water-proof performance conforming to IEC/JIS
protection grade IP67. Oil-proof performance conforms to IPXXG, and offers protection against some lubricant and cutting
oils. Tests are conducted according to the specied environments, times, and methods. However, dust-, water- and oil-proof
performance is not guaranteed in all environments. Refer to IEC 60529 (JIS C 0920) for details of testing methods. Oil-proof
performance is evaluated using typical lubricants and cutting oils (see table below), but this performance may not be fully
achieved depending on the type of oil.
• The protection degree fully achieves performance only when the ber unit, connectors, focus adjustment unit cover and lens
protection glass are attached correctly.
• Although the product features a protection degree, it cannot be used submersed in water or oil.
Test oils
Water-insoluble cutting oil
Water-soluble cutting oil
Yushiron Cut Abas BM405
Daphne Alpha Cool EW, Yushiroken EC50T5
Lubricant
Machine oil
Oil type emantcudorPepytliOemantcudorP
COSMO ALLPUS 32, Super Mulpus DX2