U= Default setting
Only Event Groups 000 to 055, 062 and 063 can be used to program the module’s PGM.
Warranty
For complete warranty information onthis product please refer to the Limited Warranty Statement found on the website www.paradox.com/terms. Your use of the Paradox product signifies your acceptance of all
warranty terms and conditions.
We strongly advise that you review and take into consideration the “Limitations of Alarm Systems” document available on our website at http://paradox.com/Terms/.
© 2003-2007 Paradox Security Systems Ltd. All rights reserved. Specifications may changewithout prior notice. Oneor more of the following US patents may apply: 7046142, 6215399, 6111256, 6104319, 5920259,
5886632, 5721542, 5287111, 5119069, 5077549 and RE39406 and otherpending patentsmay apply. Canadian and internationalpatents may also apply.
Digiplex EVO is a trademark or registered trademark of Paradox Security Systems Ltd. or its affiliates in Canada, the United States and/or other countries.
Technical Support
For technical support in Canada or the U.S., call 1-800-791-1919, Monday to Friday from 8:00 a.m. to 8:00 p.m. EST.
For technical support outside Canada and the U.S., call 00-1-450-491-7444, Monday to Friday from 8:00 a.m. to 8:00 p.m. EST.
Please feel free to visit our website at www.paradox.com.
SECTION [001]: Partition Assignment SECTION [002]: General Options 1
Option OFF ON Option OFF ON
[1] Partition 1 NDisabled UEnabled [1] Tamper Input UDisabled NEnabled
[2] Partition 2 NDisabled UEnabled [2] Battery Charging Current U350mA N850mA
[3] Partition 3 NDisabled UEnabled [3] Reader’s red LED to follow partition’s
status NDisabled UEnabled
[4] Partition 4 NDisabled UEnabled [4] Reader’s beeping to follow partition’s
status when option [3] is ON NDisabled UEnabled
[5] Partition 5 NDisabled UEnabled [5] Card activates door unlocked schedule NDisabled UEnabled
[6] Partition 6 NDisabled UEnabled [6] Door will relock UImme-
diately NWhen
closed
[7] Partition 7 NDisabled UEnabled [7] Reader’s green LED for Access
Granted NDisabled UEnabled
[8] Partition 8 NDisabled UEnabled [8] Unlock on Request for Exit (REX) NDisabled UEnabled
SECTION [003]: General Options 2 SECTION [004]: PGM Options
Option OFF ON Option OFF ON
[1] Door Left Open Alarm UDisabled NEnabled [1] PGM Deactivation After U
Deactiva-
tion Event
N
PGM Timer
[2] Door Left Open Pre-alarm NDisabled UEnabled [2] PGM Normal State UN.O. NN.C.
[3] Door Left Open Alarm NSilent UAudible [3] PGM Base Time U1 second N1 minute
[4] Door Left Open Alarm follows UAlarm
Restore NBeep
Timer [4] & [5] Special [4] [5]
[5] Door Forced Open Alarm UDisabled NEnabled NCard Only
NPIN Only
NCard and PIN
UCard or PIN
OFF
ON
OFF
ON
OFF
OFF
ON
ON
[6] Door Forced Alarm NSilent UAudible
[7] Door Forced Alarm follows UAlarm
Restore NBeep
Timer
[8] Reader Access Feedback NVisual UVisual &
audible [6] Reader Locate Feedback UVisual NVisual &
audible
[7] Unlock Door on Fire Alarm UDisabled NEnabled
[8] AC and Battery Supervision UEnabled NDisabled
Section Data Description Default
[005] __/__/__ (000 to 255 x 1 minute; 000 = Instant) AC failure report delay 030
[006] __/__/__ (001 to 255 seconds) Door Unlocked Period 005
[007] __/__/__ (001 to 255 seconds added to section [006]) Door Unlocked Period extension 015
[008] __/__/__ (001 to 255 seconds) Door Left Open Interval 060
[009] __/__/__ (001 to 255 seconds)
Time to start pre-alarm before alarm is triggered Door Left Open Pre-Alarm Timer 015
[010] __/__/__ (001 to 255 seconds) Beep timer for Door Left Open Alarm 005
[011] __/__/__ (001 to 255 seconds) Beep timer for Door Forced Open alarm 005
[012] __/__/__ (000 to 255; refer to option [3] in section [004]) PGM timer 005
[013] Door unlock schedule Start Time End Time S M T W T F S H
Schedule A:
___ ___ : ___ ___ ___ ___ : ___ ___ 1 2 3 4 5 6 7 8
Schedule B:
___ ___ : ___ ___ ___ ___ : ___ ___ 1 2 3 4 5 6 7 8
Event Group Feature Group Start # End #
Section Section Section Section
PGM Activation [014] __/__/__ [015] __/__/__ [016] __/__/__ [017] __/__/__
PGM Deactivation [018] __/__/__ [019] __/__/__ [020] __/__/__ [021] __/__/__
SECTION [022]: Safe Mode Options SECTION [031] PGM Options 2
Option OFF ON Option OFF ON
[1] Safe Mode NDisabled UEnabled [1] Flexible PGM Deactivation Option UPGM
Timer only
N Timer /
Deactivation
event
[2] Safe Mode Access NDisabled UEnabled [2] Reload Timer on Activation Event UDon’t
Reload NReload
Timer
[3] Reader Safe Mode Feedback UVisual N Visual &
audible [3] to [8] Future Use NN/A N N/A
[4] Unlock Door in Safe Mode UDisabled NEnabled
[5] Access Cards in Safe Mode USafe
Cards only NAny Cards
[6] to [8] Future Use NN/A N N/A
Section Data Description Default
[023] __/__/__ (001 to 024 hours; 000 = Disabled) Safe Mode Door Unlocked Period 000
[024] __/__/__ (001 to 255 seconds; 000 = Follow REX) REX Unlocked Period 000
[025] __/__/__ (000 to 003) Red LED Brightness 003
[026] __/__/__ (000 to 003) Green LED Brightness 003
[027] __/__/__ (000 to 003) Buzzer Frequency 001
[028] __/__/__ (000 to 255 minutes; 000 = instant) AC Restore Report Delay 005
[029] __/__/__ (000 to 255 minutes) Stay Lock Delay 000
[030] Test PGM: Activates the PGM for 8 seconds to verify if the PGM is functioning properly.
[032] __/__/__ (000 = steady, 001 to 254 = pulsed (increments of 8ms), 255 = pulsed fire) PGM Output type 000
[040] Access Card Serial Number Display: View an access card’s serial number displayed on any LCD or Grafica keypad on the combus.
When the DGP-ACM12 is in access card display mode, the door connected to the module cannot be accessed.
[061] Assign Safe Mode Access Card 1 (Present Card 3 Times)
[062] Assign Safe Mode Access Card 2 (Present Card 3 Times)
[063] Assign Safe Mode Access Card 3 (Present Card 3 Times)
[064] Assign Safe Mode Access Card 4 (Present Card 3 Times)
[070] Delete All Safe Mode Access Cards
[071] Delete Safe Mode Access Card 1
[072] Delete Safe Mode Access Card 2
[073] Delete Safe Mode Access Card 3
[074] Delete Safe Mode Access Card 4