POWER IN Blue. Glowing steadily indicates power supply OK;
o󰀨 indicates no power.
PROCESSOR Green. Glowing steadily indicates processor is
OK; o󰀨 when POWER IN is lit indicates processor
failure.
DMX INPUT Amber. Glowing steadily indicates data signal
received; o󰀨 indicates no signal present.
MENU
FUNCTION
Amber. Indicates which function is active on the
numeric display.
ISO INPUT Red. Steady glow indicates isolated 5V supply is
OK. O󰀨 indicates no power.
OUTPUT Amber. Glow approximates output level.
DMX Interface - PWINF DIN PWM4A / PWM6A
6-Channel PWM DC Dimmer Manual
08/31/21
The Pathway eDIN LED Dimmer/DC Driver provides DMX512
control over LEDs and other DC devices. Each module
provides 6 channels of control. When controlling LEDs, the
module acts as a dimming interface only. The LED xture
will require a separate regulated DC power supply, as
recommended by its manufacturer.
These instructions apply to REV 2 hardware running
rmware 1.6.2 or higher.
The PWINF DIN PWM features terminal strips that can be removed
from the card to facilitate easy wiring installation or replacement. Make
the following connections, WITH THE POWER TURNED OFF, and
observe ESD precautions by ensuring the installer is properly grounded
before handling the device.
POWER
The DMX/RDM Splitter is designed to run on a range of voltages from
9-30 volts DC. Each PWM DC Dimmer requires 5 watts. Observe the
correct polarity when connecting to V+ and V-.
A second set of terminals are provided as a DC power-through
connection to other DIN devices. The EARTH GND terminal may be
connected to the enclosure’s chassis or electrical ground terminal to
improve EMC compliance.
DMX512
DMX connections consist of a shield wire and one or two data pairs.
DMX IN is wired from the control console, or other source. DMX THRU
may be daisy-chained to the DMX IN of other eDIN cards, or to other
DMX equipment.
Connect DATA+ and DATA– wires to D1+ and D1- respectively. The
optional data pair may be connected to D2+ and D2-. Observe the same
polarity convention throughout the system. Connect the shield wire to
the SHLD/COM terminal.
DC/PWM OUTPUTS
The LED Dimmer/DC Driver interface provides six (6) outputs that will
each handle up to 4 amps at voltages up to 30VDC. The outputs are
of the current-sinking type. A separate DC power supply is required,
OVERVIEW
CONNECTIONS STATUS INDICATORS
appropriately sized for the connected load, as recommended by the
connected equipment’s manufacturer.
Each output is fully opto-isolated from the other outputs, from the
DMX signal and from the eDIN board power supply. Multiple pins
are provided to allow for load spreading. Outputs are connected
as follows:
LOAD- (Terminals 1 & 2): Connects to the negative terminal of
the load, or the LED Cathode.
V- (Terminals 3 & 4): Connects to
the negative or common terminal
of the load power supply.
V+ (Terminals 5 & 6): Connects
to the positive terminal of the load
power supply and to the positive
terminal of the load, or the LED
Anode.
OUTPUT 1
TERMINATE
LOAD-
V- IN
OFF
IN
V+
DMX THRU
ISO 5V
DMX
DMX IN
D2-
D2+
D1-
D1+
D2+
SHLD
ON
COM
D2-
D1+
COM
SHLD
D1-
POWER IN
PROCESSOR
DMX INPUT
TEST
ADDRESS
UTIL
MODE
LED/DC DRIVER
eDIN 6 CHANNEL
ENTER
V-
V+
V-
GROUND
EARTH
V+
1 532 41 532 41 532 4
1 532 4 6
IN
V+
V+ IN
V+ IN
IN
V-
LOAD-
OUTPUT 2
642 3 51
V+ IN
V+ IN
IN
V-
LOAD-
OUTPUT 3
642 3 51
V+ IN
V+ IN
IN
V-
LOAD-
OUTPUT 4
642 3 51
V+ IN
V+ IN
IN
V-
LOAD-
OUTPUT 5
642 3 51
V+ IN
V+ IN
IN
V-
LOAD-
OUTPUT 6
642 3 51
642 3 51
RNC
RNO
IN-GND
CCL
1 532 4
RCOM
AIN1
AIN2
AIN3
AIN4
AIN5
AIN6
OUTPUT RATING
5-30vdc @ 96w MAX
Internally Fused @ 4A/Output
(2 Spare Fuses Inside)
POWER IN
9-30VDC
Max 4 Watts
DMX In from
Control System Analog Inputs
(x6)
DMX Thru to
other DIN devices
Contact Closure
“Panic” Input
Status LEDs
Analog /
Contact
Input
Common
DMX Present
Relay
(Normally-open,
Normally-closed,
and Relay
common)
Menu
Function LEDs
Power In:
9-30VDC, 5W Supply required.
Use PWPWR DIN TERM [xxxx]
NOT FOR LED LOADS. Use separate
power supply for LEDs.
Connect Earth ground to improve
EMC compliance
End of line
DMX512
termination switch
Isolated Solid-state switch outputs (x6)
5-30VDC (External Supply Required)
4A or 6A @ 30VDC Max
4.07”
[103.4mm]
8.0”
[203mm]
1.85”
[47mm]
LED numeric
display
Program
pushbuttons
Fastening mechanism
designed for 35 X 7.5mm
DIN rail
DIN rail release lever
Use large flat-head screwdriver or
similar tool to gently pry lever
away from DIN rail to release
DMX Interface - PWINF DIN PWM4A / PWM6A
6-Channel PWM DC Dimmer Manual
08/31/21
DMX rules require the nal device in-line have a terminating resistor. If
there are other devices connected to the DMX THRU terminals, the DMX
TERMINATE switch should be OFF. Otherwise the terminator should
be ON.
The PWINF DIN PWM DC Dimmer is fully compliant with ANSI E1.20
Remote Device Management as a responder device. An RDM controller
can discover and retrieve the card’s DMX start address, rmware version
and operating mode (personality). DMX start address and operating
mode are remotely congurable by the controller. Starting with rmware
1.5.5, an RDM utility can upgrade the rmware in the eld.
The #1008 eDIN LED Dimmer does not regulate the current supplied
to the LED. Always use a current-regulated power supply, approved by
the LED manufacturer, to supply the LED xture.
The DIN Interface has 2 operating modes: Function and Edit. Press the
▲ or ▼ buttons to select a function, as indicated by the LEDs next to
ADDRESS, MODE, UTIL, and TEST. Once selected, press and hold
the ENTER button until a dot appears in the lower right-hand corner of
the display. The card is now in EDIT mode. Use the ▲ or ▼ buttons to
change, then press ENTER to accept the new value.
Once in ADDRESS edit mode, press ▲ or ▼ to change the start address
to the desired value between 1 and 512. Press ENTER to save the new
start address.
There are four UTIL modes.
A: Adjusts the smoothing algorithm between 1 (very smooth) to 100 (no
smoothing). Factory default is 64.
B: Sets a MIN output level between 0 (default) and 255, that the card
will output in the absence of DMX.
C: Adjusts a Grand Master maximum output level between 0 (o󰀨) and
FL (100% - default).
D: Sets DMX signal loss behavior. Options are “0” - zero seconds, “0.5”
- thirty seconds, “1” - one minute, “5” - ve minutes and “--” forever
(default).
Mode 1: Default LED Control Mode (6 channels)
The incoming DMX channel level is interpolated to produce a 16-bit
value. A weighted fade curve is also applied to compensate for LED
response, producing an apparently linear fade to the human eye.
Mode 2: DMX Double Precision Mode with Curve (12 channels)
Two DMX control channels are used to produce a 16-bit value for each
output. A weighted curve is also applied.
Mode 3: DMX Double Precision Mode without Curve (12 channels)
Two DMX control channels are used to produce a 16-bit value for each
output with no compensating curve. Output follows the DMX values
linearly.
Mode 4: Non-Dim Mode
When the DMX channel is below 50%, the corresponding output will
be o󰀨. When the channel level is above 50%, the corresponding output
will be on (full). Use for nondimming loads such as solid state relays or
solenoid coils.
Mode 5: Single channel control
One DMX channel, the start address, controls all six outputs from the
module.
Mode 6: 3 Channel Mirror Mode with Curve (3 channels)
Outputs are paired (1/4, 2/5, 3/6). Paired outputs are driven by the same
DMX channel, with the weighted curve applied to the output.
DMX TERMINATION
RDM RESPONDER FEATURES
COMENTARY ON DIMMING LEDs
CONFIGURATION
SET DMX ADDRESS
UTIL MODE
SET OPERATING MODE
Use ▲ or ▼ to cycle the display from 1 through 6. The corresponding
output will be at full. Normal DMX input will be ignored. Press ENTER
to exit test mode.
TEST MODE
Wire RCOM to RNC or RNO for a normally closed or normally open
DMX indicator, as desired.
When DMX is present, the closure will be held in a state opposite to its
‘normal’ position.
When CCL is shorted to IN-GND, for example by closing an e-stop
switch, all outputs are forced to the MAX output level, regardless of DMX
level or signal presence.
Applying a 0-10VDC input between any AIN(x) and the IN-GND pin will
drive that particular output. Output level is an HTP-merge between the
DC voltage level and the incoming DMX signal for that channel.
Do not exceed 10VDC maximum input voltage.
DMX PRESENT RELAY CLOSURE
CONTACT CLOSURE PANIC INPUT
ANALOG INPUT
Mode 7: 3 Channel Mirror Mode without Curve (3 channels)
Outputs are paired (1/4, 2/5, 3/6). Paired outputs are driven by the
same DMX channel, with no compensating curve. Output follows the
DMX values linearly.
DMX Interface - PWINF DIN PWM4A / PWM6A
6-Channel PWM DC Dimmer Manual
08/31/21
© 2021 Acuity Brands, Inc. • One Lithonia Way, Conyers GA 30012
Pathway Connectivity | #103 - 1439 17th Ave SE Calgary, AB Canada T2G 1J9
Phone: + 1 866 617 3074 www.pathwayconnect.com
• Power input: 9-30VDC (DO NOT USE main device supply also for LED loads; use separate supply)
• 5W maximum power consumption
• 4A or 6A Switched output (PWM4A or PWM6A model) (must use external power source appropriate for loads)
• Isolation: 1500V isolation between DMX output and analog/contact inputs
• Fault protection: 250V fault protection on DMX port
ELECTRICAL INFORMATION
• ANSI E1.11 DMX512-A R2013
• ANSI E1.20 RDM - Remote Device Management
COMPLIANCE
• 8.0”W x 4”H x 1.85”D (203mm x 103mm x 47mm)
• 0.7 lbs (0.32 kg)
• Operating Conditions: 14°F-113°F (-10°C to 45°C); 5-95% relative humidity, non-condensing
PHYSICAL

This manual suits for next models

1

Popular Dimmer manuals by other brands

WorkPro DUO DIM user manual

WorkPro

WorkPro DUO DIM user manual

Show Tec Lite Power Classic user manual

Show Tec

Show Tec Lite Power Classic user manual

North Light ML50C2-PV manual

North Light

North Light ML50C2-PV manual

Clas Ohlson EFP700DC+EFV001 Guide

Clas Ohlson

Clas Ohlson EFP700DC+EFV001 Guide

AMX Dual DC Dimmer Module RDM-2DC installation guide

AMX

AMX Dual DC Dimmer Module RDM-2DC installation guide

Alpha JO-CONTR-020/8 quick start guide

Alpha

Alpha JO-CONTR-020/8 quick start guide

GEV LightBoy LDV manual

GEV

GEV LightBoy LDV manual

Leviton DDS6000 user manual

Leviton

Leviton DDS6000 user manual

Lutron Electronics Hi-Lume Premier 0.1% manual

Lutron Electronics

Lutron Electronics Hi-Lume Premier 0.1% manual

LEGRAND KNX modular dimmer Technical data sheet

LEGRAND

LEGRAND KNX modular dimmer Technical data sheet

MBNLED L50002D1 installation manual

MBNLED

MBNLED L50002D1 installation manual

Leviton 6613-PL installation instructions

Leviton

Leviton 6613-PL installation instructions

LiteGear LiteDimmer Pro Single user guide

LiteGear

LiteGear LiteDimmer Pro Single user guide

ARTISAN LIGHTING PHUKET PE389 quick start guide

ARTISAN LIGHTING PHUKET

ARTISAN LIGHTING PHUKET PE389 quick start guide

AMX RDM-3FDB Notice

AMX

AMX RDM-3FDB Notice

PXM PX155 user manual

PXM

PXM PX155 user manual

Prostage S1-D1 user guide

Prostage

Prostage S1-D1 user guide

Newlab L400MC04T1A01 user manual

Newlab

Newlab L400MC04T1A01 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.