Patron E3 User manual

1
Patron E3 - 12/00
USER’S MANUAL FOR
PATRON E3
ELECTRIC FAN HEATER
(12/00)
IMPORTANT
READ AND UNDERSTAND THIS MANUAL
BEFORE ASSEMBLING, STARTING OR
SERVICING THE HEATER.
IMPROPER USE OF HEATER CAN CAUSE
SERIOUS INJURY.
KEEP THIS MANUAL FOR FUTURE REFERENCE.
FOR PROFESSIONAL USE ONLY

2
Patron E3 - 12/00
READ ALL INSTRUCTIONS BEFORE USING THIS HEATER
1. This heater is hot when in use. To avoid burns, do not let bare skin touch hot sur-
faces. Use handle when moving this heater. Keep combustible materials at least 6
feet (2 meter) from the front of the heater and keep them away from sides and rear
2. Extreme caution is necessary when the heater is used near children or invalids and
whenever the heater is left unattended
3. Always unplug the heater when not in use
4. Do not operate any heater with a damaged cord or plug or after the heater malfunc-
tions, has been dropped or damaged in any manner. Return heater to authorized
service facility for examination, electrical or mechanical adjustment or repair
5. Do not expose to rain, water spray or dripping water
6. This heater is not intended for use in bathrooms, laundry areas and similar indoor lo-
cations. Never locate the heater where it may fall into a bathtub or other liquid con-
tainer
7. Do not run cord under carpeting. Do not cover cord with throw rugs, runners, or the
like. Arrange cord away from traffic area and where it will not be tripped over
8. To disconnect heater, turn controls to off, then remove plug from outlet
9. Connect to properly grounded outlets only
10. Do not insert or allow foreign objects to enter any ventilation or exhaust opening as
this may cause an electric shock or fire, or damage the heater
11. To prevent a possible fire, do not block air intakes or exhaust in any manner. Do not
use on soft surfaces, where openings may become blocked
12. A heater has hot and arcing or sparking parts inside. Do not use in areas where
gasoline, paint or flammable liquids are used or stored
13. Do not point to flammable materials
14. Use heater only as described in this manual. Any other use not recommended by
the manufacturer may cause fire, electric shock or injury to persons
15. Avoid use of an extension cord because it may overheat and cause a risk of fire.
However, if you have to use an extension cord, the cord shall be a three (3) wire
grounded cord (check minimum size from specifications)

3
Patron E3 - 12/00
1. GENERAL INFORMATION FOR USER
Patron electric heaters are designed for professional use.
The heat is generated in sealed heating elements inside the inner mantle of the
heater. Heated air is then distributed by an electric motor driven fan blowing air
through the heater.
Although effectively cooled by the fan, the heating elements have high surface
temperatures. That is why combustible materials must be kept at a safe distance
from the heater and care must be taken that no combustible particles enter the
heater with the air sucked in by the fan.
Keep the heater clean of dust at any time. Dust may cause fire when heated.
Make sure that the fan blades may rotate unobstructed at all times.
Do not block air intakes or exhaust in any manner.
2. LIMITED WARRANTY
PATRON heater products are professional construction heaters. They are warranted for
twenty-four (24) months from original date of purchase. The warranty does not cover
products modified outside our factory, damage or failure caused by acts of God, abuse,
misuse, use on other than rated voltage, abnormal usage, faulty or improper installation,
failure to provide recommended maintenance or any repairs other than those provided
by an authorized PATRON service.
THERE ARE NO OBLIGATIONS OR LIABILITIES ON THE PART OF PATRON PROD-
UCTS INC. FOR CONSEQUENTIAL DAMAGES ARISING OUT OF OR IN CONNEC-
TION WITH THE USE OR PERFORMANCE OF THE PRODUCT OR OTHER INDIRECT
DAMAGES WITH RESPECT TO LOSS OF PROPERTY, REVENUES, OR PROFIT, OR
COST OF REMOVAL, INSTALLATION OR REINSTALLATION.
THIS WARRANTY CONSTITUTES THE EXCLUSIVE REMEDY OF ANY PURCHASER
OF EQUIPMENT SOLD BY THE MANUFACTURER AND ITS DEALERS AND DIS-
TRIBUTORS AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED.
During the warranty period, Patron Products will, at its sole option, repair or replace any
defective parts or products returned, freight prepaid, to Patron Products or such other lo-
cation as Patron Products may designate.
Returned products must be packaged carefully, and Patron Products shall not be re-
sponsible for damage in transit. When returning parts, the owner must provide the model
number of the product and the nature of difficulty being experienced. This warranty does
not oblige Patron Products to bear the cost of labour in replacing any assembly, unit or
component or part thereof, nor does the company assume any liability for secondary
charges, expenses of removal or installing, freight or damages. There will be charges
rendered for product repair after our warranty period has expired. Proof of purchase, in-
cluding date, must accompany request for in-warranty service.

4
Patron E3 - 12/00
3. OPERATION
REVIEW AND UNDERSTAND ALL WARNINGS IN THIS MANUAL.
THEY ARE ESSENTIAL FOR SAFE USE OF THE HEATER.
FOLLOW ALL LOCAL CODES.
This heater is for use on 240 volts.
The cord has a plug as shown in the figure.
The type of outlet is a 240-volt grounding outlet. When properly installed, it pro-
vides a ground connection through the cord to the heater to protect the operator
from electric shock.
TO START HEATING:
1. Place the heater on a stable and level surface. Make sure that no explosive
or combustible fumes or dust are present
2. Connect power cord of heater into 240 V / 60 Hz power source. See para-
graph “Technical specifications” in this manual for correct amperage rating
3. Set the thermostat to a temperature above the ambient room temperature by
turning the knob. Note! The heater will start only if the thermostat “calls for
heat” meaning that it is set to higher than prevailing ambient temperature
4. The heater will now operate automatically, controlled by the thermostats
TO STOP HEATING:
1. Turn the thermostat into “OFF” position
2. Disconnect the power supply plug
NOTE!
THE HEATER IS EQUIPPED WITH AN OVERHEAT LIMIT SWITCH WHICH
MAY CAUSE THE HEATER TO STOP.
CHECK AND REMOVE THE CAUSE FOR OVERHEATING BEFORE RE-
STARTING.
MINIMUM CLEARANCES FROM COMBUSTIBLE MATERIALS:
OUTLET = 6 feet SIDES = 1 foot
TOP = 2 feet REAR = 2 feet
FLOOR = COMBUSTIBLE
15 A 250 V
Grounding pin

5
Patron E3 - 12/00
4. MAINTENANCE
WARNING!
NEVER SERVICE THE HEATER WHILE IT IS PLUGGED IN, RUNNING OR
HOT. SEVERE BODILY INJURE OR ELECTRIC SHOCK MAY OCCUR.
ONLY QUALIFIED PERSONS ARE ALLOWED TO OPEN HEATER FOR SERV-
ICE. NO USER-SERVICEABLE PARTS INSIDE.
•Keep heater clean. Use pressurized air to blow fan blades clean. Note! Use
moderate pressure to avoid damage to fan blades
•Inspect heater before and after each use
•The fan motor is sealed and has permanently lubricated bearings
5. STORAGE
When not in use, the heater must be disconnected from power source, cleaned of
dust and stored in a dry place.
The power supply cord should be loosely wound around the handle of the heater.
6. TECHNICAL SPECIFICATIONS
MODEL PATRON E3
Heat output BTU/hr 10,200 (3,000 W)
Air flow CFM 205 (350 m³/h)
Electric connection V ac / Hz 240 / 60, single phase
Amperage draw A12.5
Power cord 3×16 AWG
Plug NEMA 6-15P
Extension cord min. 3×16 AWG
Ambient thermostat Temp.range 32 ... 100 °F (0 ... 40 °C)
Length inches 11.8 (300 mm)
Width inches 10.2 (260 mm)
Height inches 15.2 (385 mm)
Weight lbs 20.3 (9.2 kg)

6
Patron E3 - 12/00
7. EXPLODED VIEW
Pos. Patron E3 - Code #
1bottom plate plaque de fond 4934001
2front panel panneau avant 4934002
3rear panel panneau arriere 4934003
4outer mantle carcasse 4934004
5inner mantle cheminee interieure 4934005
6handle poignee 80100
7heating element element 42800
8 fan motor motor du ventilateur 14104
9 fan blade pales du ventilateur 16200
10 hub moyeu 17907
11 room thermostat + knob thermostat ambiant 20405+20570
12 overheat limit switch disjoncteur de surchauffe 21200

7
Patron E3 - 12/00
Pos. Patron E3 - Code #
Mfan motor motor du ventilateur 14104
Rheating element element 42800
S2 room thermostat thermostat ambiant 20405
S3 overheat limit switch disjoncteur de surchauffe 21200
X1 terminal block bloc terminal 36701
X2 grounding lug bloc terre —-
X3 power cord & plug fil electrique & fiche 30320
strain reliever retenue de fil 36910
t
8. WIRING DIAGRAM

8
Patron E3 - 12/00
PATRON PRODUCTS INC.
USA: 60 Clyde Avenue Suite # 4, Buffalo, NY 14215
Canada: 12-110 Ironside Crescent, Scarborough, Ontario M1X 1M2
Table of contents
Other Patron Heater manuals