Patron 40ECA User manual

40ECA ELECTRIC FAN HEATER
PRODUCT MANUAL
IMPORTANT
READ AND UNDERSTAND THIS MANUAL BEFORE ASSEM-
BLING, STARTING OR SERVICING THE HEATER.
IMPROPER USE OF HEATER CAN CAUSE SERIOUS INJURY.
KEEP THIS MANUAL FOR FUTURE REFERENCE.
FOR PROFESSIONAL USE ONLY
RENTQUIP USA INC. | 1-800-818-1199 | WWW.PATRONPRODUCTS.COM
MAY 2018 REVISION

40ECA PRODUCT MANUAL
RENTQUIP USA INC. | 1-800-818-1199 | WWW.PATRONPRODUCTS.COM
IMPORTANT INSTRUCTIONS
READ ALL INSTRUCTIONS BEFORE USING THIS HEATER
1. This heater is hot when in use. To avoid burns, do not let bare skin touch hot surfaces. Use handle when
moving this heater. Keep combustible materials at least 6 feet (2 meter) from the front of the heater and keep
them away from sides and rear
2. Extreme caution is necessary when the heater is used near children or invalids and whenever the heater is
left unattended
3. Always unplug the heater when not in use
4. Do not operate any heater with a damaged cord or plug or after the heater malfunctions, has been dropped
or damaged in any manner. Return heater to authorized service facility for examination, electrical or mechanical
adjustment or repair
5. Do not use outdoors
6. This heater is not intended for use in bathrooms, laundry areas and similar indoor locations. Never locate the
heater where it may fall into a bathtub or other liquid container
7. Do not run cord under carpeting. Do not cover cord with throw rugs, runners, or the like. Arrange cord away
from trac area and where it will not be tripped over
8. To disconnect heater, turn controls to o, then remove plug from outlet
9. Connect to properly grounded outlets only
10. Do not insert or allow foreign objects to enter any ventilation or exhaust opening as this may cause an elec-
tric shock or re, or damage the heater
11. To prevent a possible re, do not block air intakes or exhaust in any manner. Do not use on soft surfaces,
where openings may become blocked
12. A heater has hot and arcing or sparking parts inside. Do not use in areas where gasoline, paint or ammable
liquids are used or stored
13. Do not point to ammable materials
14. Use heater only as described in this manual. Any other use not recommended by the manufacturer may
cause re, electric shock or injury to persons
15. Always plug heaters directly into a wall outlet/receptacle. Never use with an extension cord or relocatable
power tap (outlet/power strip)
16. SAVE THESE INSTRUCTIONS

RENTQUIP USA INC. | 1-800-818-1199 | WWW.PATRONPRODUCTS.COM
40ECA PRODUCT MANUAL
RENTQUIP USA INC. | 1-800-818-1199 | WWW.PATRONPRODUCTS.COM
GENERAL INFORMATION FOR USER
Patron electric heaters are designed for professional use.
The heat is generated in sealed heating elements inside the inner mantle of the heater. Heated air is then dis-
tributed by an electric motor driven fan blowing air through the heater.
Although eectively cooled by the fan, the heating elements have high surface temperatures. That is why com-
bustible materials must be kept at a safe distance from the heater and care must be taken that no combustible
particles enter the heater with the air sucked in by the fan.
Keep the heater clean of dust at any time. Dust may cause re when heated.
Make sure that the fan blades may rotate unobstructed at all times.
Do not block air intakes or exhaust in any manner.
LIMITED WARRANTY
PATRON heater products are professional construction heaters. They are warranted for twenty-four (24) months
from original date of purchase. The warranty does not cover products modied outside our factory, damage
or failure caused by acts of God, abuse, misuse, use on other than rated voltage, abnormal usage, faulty or
improper installation, failure to provide recommended maintenance or any repairs other than those provided by
an authorized PATRON service.
THERE ARE NO OBLIGATIONS OR LIABILITIES ON THE PART OF PATRON PRODUCTS INC. FOR CON-
SEQUENTIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH THE USE OR PERFORMANCE OF
THE PRODUCT OR OTHER INDIRECT DAMAGES WITH RESPECT TO LOSS OF PROPERTY, REVENUES,
OR PROFIT, OR COST OF REMOVAL, INSTALLATION OR REINSTALLATION.
THIS WARRANTY CONSTITUTES THE EXCLUSIVE REMEDY OF ANY PURCHASER OF EQUIPMENT
SOLD BY THE MANUFACTURER AND ITS DEALERS AND DISTRIBUTORS AND IS IN LIEU OF ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED.
During the warranty period, Patron Products will, at its sole option, repair or replace any defective parts or prod-
ucts returned, freight prepaid, to Patron Products or such other location as Patron Products may designate.
Returned products must be packaged carefully, and Patron Products shall not be responsible for damage in
transit. When returning parts, the owner must provide the model number of the product and the nature of dif-
culty being experienced. This warranty does not oblige Patron Products to bear the cost of labour in replac-
ing any assembly, unit or component or part thereof, nor does the company assume any liability for secondary
charges, expenses of removal or installing, freight or damages. There will be charges rendered for product
repair after our warranty period has expired. Proof of purchase, including date, must accompany request for in-
warranty service.

40ECA PRODUCT MANUAL
RENTQUIP USA INC. | 1-800-818-1199 | WWW.PATRONPRODUCTS.COM
OPERATION
REVIEW AND UNDERSTAND ALL WARNINGS IN THIS MANUAL. THEY ARE ESSENTIAL FOR SAFE USE
OF THE HEATER.
FOLLOW ALL LOCAL CODES
TO START HEATING:
1. Place the heater on a stable and level surface. Make sure that no explosive or combustible fumes or dust
are present.
MINIMUM CLEARANCES FROM COMBUSTABLE MATERIALS
OUTLET = 6 feet SIDES = 1 foot
TOP = 2 feet REAR = 2 feet
FLOOR = COMBUSTABLE
2. Connect power cord of heater into 575 V / 60 Hz three phase power source. THE POWER SOURCE MUST
BE EQUIPPED WITH A CIRCUIT BREAKER! See paragraph “Technical specications” in this manual for
correct amperage rating. NOTE: Check your heater to make sure it is wired for either one or three phase
use.
3. Set the room thermostat to a temperature above the ambient room temperature by turning the knob. Note!
The heater will start heating only if the thermostat “calls for heat” meaning that it is set to higher than pre-
vailing ambient temperature
Select the power range by means of the switches marked S1, S2 and S3.
S1 “ON” = Partial output 16 kW (51,200 BU/h)
S1 & S2“ON” = Partial output 32 kW (102,400 BU/h)
S1 & S2 & S3 “ON” = Full output 40 kW (136,500 BU/h)
THE HEATER WILL NOW OPERATE AUTOMATICALLY, CONTROLLED BY THE THERMOSTATS.
TO STOP HEATING
1. Turn the main switch into position “0” standby
2. Let the fan run until it stops automatically - do not disconnect heater from power source!
3. Disconnect the power supply plug
NOTE!
THE HEATER IS EQUIPPED WITH AN OVERHEAT LIMIT SWITCH WHICH MAY CAUSE THE HEATER TO
STOP. CHECK AND REMOVE THE CAUSE FOR OVERHEATING BEFORE RESTARTING.
RENTQUIP USA INC. | 1-800-818-1199 | WWW.PATRONPRODUCTS.COM

RENTQUIP USA INC. | 1-800-818-1199 | WWW.PATRONPRODUCTS.COM
40ECA PRODUCT MANUAL
RENTQUIP USA INC. | 1-800-818-1199 | WWW.PATRONPRODUCTS.COM
MAINTENANCE
WARNING!
NEVER SERVICE THE HEATER WHILE IT IS PLUGGED IN, RUNNING OR HOT. SEVERE BODILY INJURE
OR ELECTRIC SHOCK MAY OCCUR.
ONLY QUALIFIED PERSONS ARE ALLOWED TO OPEN HEATER FOR SERVICE. NO USER-SERVICE-
ABLE PARTS INSIDE.
• Keep heater clean. Use pressurized air to blow fan blades clean. Note! Use moderate pressure to avoid
damage to fan blades
• Inspect heater before and after each use
• The bearings of the fan motor must be lubricated according to instructions on the motor
STORAGE
When not in use, the heater must be disconnected from power source, cleaned of dust and stored in a dry
place.
TECHNICAL SPECIFICATIONS
HEAT OUTPUT
(3 STAGE SELECTOR)
BTU/Hr 51,200 / 102,400 / 136,500
AIRFLOW CFM 1,765
ELECTRIC CONNECTION V ac / Hz 575 / 60 three phase
AMPERAGE DRAW (3 Phase) A Partial: 17
Partial: 33
Full: 41
AMBIENT THERMOSTAT temp. range 32 - 100 °F (0 - 40 °C)
LENGTH inches 46
WIDTH inches 20
HEIGHT inches 25
WEIGHT lbs 125

40ECA PRODUCT MANUAL
RENTQUIP USA INC. | 1-800-818-1199 | WWW.PATRONPRODUCTS.COM
SPARE PARTS
DIAGRAM
PATRON 40ECA
Drawing 1
1 404103 Heat Exchange Chamber
2 404103 Heat Exchange Chamber
3 404103 Heat Exchange Chamber
4 404102 Hood (Incl. Connection Hatch)
5 404104 Connection Hatch Only
6 404101 Handle
7 404106 Front Panel
8 404108 Duct Adapter
9 404107 Bottom Frame
10 404111 Support Leg
11 404105 Wheel Shaft
A
A
1
2
3
4
5
6
9
10
11
78
19
14
13
20
17
18
15
16
Dwg. 2
2
21
12
Patron 40E / 40E CA
12 404112 Fan Thermostat Plate
13 21200 Overheat Limit Switch, Inner
14 21100 Cooldown Thermostat
15 20550 Overheat Limit Switch, Air Outlet
16 82770 Metal Bracket for 20550 Switch
17 74200 Wheel
18 74600 Locking Washer
19 404113 Gasket, Duct Adapter
20 42411 Heating Element, 15 per heater
21 36809 Guard Ring

RENTQUIP USA INC. | 1-800-818-1199 | WWW.PATRONPRODUCTS.COM
40ECA PRODUCT MANUAL
RENTQUIP USA INC. | 1-800-818-1199 | WWW.PATRONPRODUCTS.COM
24 404115 Rear Panel + Fan Enclosure
25 404109 Partition Panel
26 404110 Contactor Mounting Plate
28 404118 Fan Mounting Plate
29 83900 Fan Guard Grill
30 36804 Bushing, Medium
31 36805 Bushing, Large
32 22669 Contactor (3/Heater)
33 22560 Contactor (1/Heater)
34 36905 Strain Reliever
35 26900 Toggle Switch
36 38111 + 38110 Fuse + Fuse Holder
37 36615 Terminal Block
38 28405 Transformer
39 36630 Locking Clamp (2/Heater)
40 37910 Plastic Bracket
41 20220 Ambient Thermostat
42 20577 Thermostat Knob
43 404116 Bolt, ground
45 14305 Fan Motor
46 14310 Power Cord, Fan Motor (per ft)
47 16351 Fan Blade
48 36802 Bushing, Small
SPARE PARTS
DIAGRAM
PATRON 40ECA
Drawing 2
29
24
41
40
41
36 31
46
48
43
34
38
26
48
32
15
33
37
39
30
25
30
47
28
45
42
Patron 40E ja 60E
Käytetty manuaalissa 2018 Revision
32
35

40ECA PRODUCT MANUAL
RENTQUIP USA INC. | 1-800-818-1199 | WWW.PATRONPRODUCTS.COM
WIRING DIAGRAM
C1 Contactor 22560
C1/4 Pole 4 of contactor C1 (open) -
C2/C3/C4 Contactor 22669
F1 Fuse 38111
M Fan motor 14305
R1...R15 Heating element 42411
S1 Toggle switch for 16 kW output 26900
S2 Toggle switch for +16kW output 26900
S3 Toggle switch for +8kW output 26900
TA Ambient Thermostat 20220
TC Cooldown thermostat 21100
TO 1 Overheat limit switch (inner) 21200
TO 2 Overheat limit switch (discharge) 20550
TR Transformer 575V/24 V, AC 28405
X1 Terminal Block 36615

PATRON PRODUCTS
A DIVISION OF RENTQUIP
1-800-818-1199
www.patronproducts.com
Table of contents
Other Patron Heater manuals
Popular Heater manuals by other brands

BIEMMEDUE
BIEMMEDUE GP 10M C instruction manual

Klarstein
Klarstein Florentina IR instruction manual

USSC
USSC Ashley EC95 Installation, operation and maintenance instructions

Cordivari
Cordivari 5240000000034 user manual

Siemens
Siemens DE 1113415 Installation and operating instructions

Frost Fighter
Frost Fighter IDF500HS Installation - Operation/Maintenance Instructions and Parts List