manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. PCB Piezotronics
  6. •
  7. Accessories
  8. •
  9. PCB Piezotronics 350C04 User manual

PCB Piezotronics 350C04 User manual

Model 350C04
ICP® Shock Accelerometer
Installation and Operating Manual
For assistance with the operation of this product,
contact PCB Piezotronics, Inc.
Toll-free: 800-828-8840
24-hour SensorLine: 716-684-0001
Fax: 716-684-0987
E-mail: [email protected]
Web: www.pcb.com
The information contained in this document supersedes all similar information that
may be found elsewhere in this manual.
Total Customer Satisfaction – PCB
Piezotronics guarantees Total Customer
Satisfaction. If, at any time, for any
reason, you are not completely satisfied
with any PCB product, PCB will repair,
replace, or exchange it at no charge. You
may also choose to have your purchase
price refunded in lieu of the repair,
replacement, or exchange of the product.
Service – Due to the sophisticated nature
of the sensors and associated
instrumentation provided by PCB
Piezotronics, user servicing or repair is
not recommended and, if attempted, may
void the factory warranty. Routine
maintenance, such as the cleaning of
electrical connectors, housings, and
mounting surfaces with solutions and
techniques that will not harm the
physical material of construction, is
acceptable. Caution should be observed
to insure that liquids are not permitted to
migrate into devices that are not
hermetically sealed. Such devices should
only be wiped with a dampened cloth
and never submerged or have liquids
poured upon them.
Repair – In the event that equipment
becomes damaged or ceases to operate,
arrangements should be made to return
the equipment to PCB Piezotronics for
repair. User servicing or repair is not
recommended and, if attempted, may
void the factory warranty.
Calibration – Routine calibration of
sensors and associated instrumentation is
recommended as this helps build
confidence in measurement accuracy and
acquired data. Equipment calibration
cycles are typically established by the
users own quality regimen. When in
doubt about a calibration cycle, a good
“rule of thumb” is to recalibrate on an
annual basis. It is also good practice to
recalibrate after exposure to any severe
temperature extreme, shock, load, or
other environmental influence, or prior
to any critical test.
PCB Piezotronics maintains an ISO-
9001 certified metrology laboratory and
offers calibration services, which are
accredited by A2LA to ISO/IEC 17025,
with full traceablility to N.I.S.T. In
addition to the normally supplied
calibration, special testing is also
available, such as: sensitivity at elevated
or cryogenic temperatures, phase
response, extended high or low
frequency response, extended range, leak
testing, hydrostatic pressure testing, and
others. For information on standard
recalibration services or special testing,
contact your local PCB Piezotronics
distributor, sales representative, or
factory customer service representative.
Returning Equipment – Following
these procedures will insure that your
returned materials are handled in the
most expedient manner. Before returning
any equipment to PCB Piezotronics,
contact your local distributor, sales
representative, or factory customer
service representative to obtain a Return
Warranty, Service, Repair, and
Return Policies and Instructions
Materials Authorization (RMA)
Number. This RMA number should be
clearly marked on the outside of all
package(s) and on the packing list(s)
accompanying the shipment. A detailed
account of the nature of the problem(s)
being experienced with the equipment
should also be included inside the
package(s) containing any returned
materials.
A Purchase Order, included with the
returned materials, will expedite the
turn-around of serviced equipment. It is
recommended to include authorization
on the Purchase Order for PCB to
proceed with any repairs, as long as they
do not exceed 50% of the replacement
cost of the returned item(s). PCB will
provide a price quotation or replacement
recommendation for any item whose
repair costs would exceed 50% of
replacement cost, or any item that is not
economically feasible to repair. For
routine calibration services, the Purchase
Order should include authorization to
proceed and return at current pricing,
which can be obtained from a factory
customer service representative.
Warranty – All equipment and repair
services provided by PCB Piezotronics,
Inc. are covered by a limited warranty
against defective material and
workmanship for a period of one year
from date of original purchase. Contact
PCB for a complete statement of our
warranty. Expendable items, such as
batteries and mounting hardware, are not
covered by warranty. Mechanical
damage to equipment due to improper
use is not covered by warranty.
Electronic circuitry failure caused by the
introduction of unregulated or improper
excitation power or electrostatic
discharge is not covered by warranty.
Contact Information – International
customers should direct all inquiries to
their local distributor or sales office. A
complete list of distributors and offices
can be found at www.pcb.com.
Customers within the United States may
contact their local sales representative or
a factory customer service
representative. A complete list of sales
representatives can be found at
www.pcb.com. Toll-free telephone
numbers for a factory customer service
representative, in the division
responsible for this product, can be
found on the title page at the front of this
manual. Our ship to address and general
contact numbers are:
PCB Piezotronics, Inc.
3425 Walden Ave.
Depew, NY 14043 USA
Toll-free: (800) 828-8840
24-hour SensorLineSM: (716) 684-0001
Website: www.pcb.com
E-mail: [email protected]
DOCUMENT NUMBER: 21354
DOCUMENT REVISION: B
ECN: 17900
Model Number
350C04 ICP® SHOCK ACCELEROMETER Revision: NR
ECN #: 43883
Performance ENGLISH SI
Sensitivity(± 30 %) .0 mV/g 0. 0 mV/(m/s²)
Measurement Range ± 5000 g pk ± 49,000 m/s² pk
Frequency Range(± dB) 0.4 to 0,000 Hz 0.4 to 0,000 Hz
Frequency Range(-3 dB) 0.2 to 25,000 Hz 0.2 to 25,000 Hz [2]
Electrical Filter Corner Frequency(-3 dB) 2 kHz 2 kHz [ ][3]
Mechanical Filter Resonant Frequency 35 kHz 35 kHz [ ][4]
Resonant Frequency ≥ 00 kHz ≥ 00 kHz
Broadband Resolution( to 0,000 Hz) 0.02 g rms 0.20 m/s² rms [ ]
Non-Linearity ≤ 2.0 % ≤ 2.0 %
Transverse Sensitivity ≤ 7 % ≤ 7 %
Environmental
Overload Limit(Shock) ± 50,000 g pk ± 490,000 m/s² pk
Temperature Range(Operating) 0 to + 50 °F - 8 to +66 °C
Temperature Range(Storage) -40 to +200 °F -40 to +93 °C
Temperature Response See Graph See Graph
Base Strain Sensitivity 0.002 g/µε 0.02 (m/s²)/µε [ ]
Electrical
Excitation Voltage 20 to 30 VDC 20 to 30 VDC
Constant Current Excitation 2 to 20 mA 2 to 20 mA
Output Impedance ≤ 200 Ohm ≤ 200 Ohm
Output Bias Voltage 8 to 4 VDC 8 to 4 VDC
Discharge Time Constant .0 to 2.0 sec .0 to 2.0 sec [ ]
Settling Time(within 0% of bias) < 0 sec < 0 sec
Phy ical
Sensing Element Ceramic Ceramic
Sensing Geometry Shear Shear
Housing Material Titanium Titanium
Sealing Hermetic Hermetic
Size (Hex x Height) 0.375 in x . 5 in 9.5 mm x 29.2 mm
Weight 0. 9 oz 5.4 gm [ ]
Electrical Connector 0-32 Coaxial Jack 0-32 Coaxial Jack
Electrical Connection Position Top Top
Mounting Thread /4-28 Male /4-28 Male
[5]
All specifications are at room temperature unless otherwise specified.
In the interest of constant product improvement, we reserve the right to change specifications without notice.
ICP® is a registered trademark of PCB Group, Inc.
M- Metric Mount
Mounting Thread M6 x 0.75 Male M6 x 0.75 Male
W- Water Resistant Cable
Electrical Connector Sealed Attached Cable Sealed Attached Cable
NOTES:
[ ]Typical.
[2]Typical corner frequency for coupled electrical and mechanical filters.
[3]Electrical filter is a second order filter.
[4]Amplitude at resonance is +9 dB.
[5]See PCB Declaration of Conformance PS023 for details.
SUPPLIED ACCESSORIES:
Model ACS- 4 High G shock accelerometer calibration using Hopkinson bar. ( )
Model ACS-22 NIST Traceable frequency response ( 00Hz to ± dB point) ( )
3425 Walden Avenue, Depew, NY 4043
Phone: 716-684-0001
Fax: 716-684-0987
E-Mail: info@pcb com
OPTIONAL VERSIONS
Optional versions have identical specifications and accessories as listed for the standard model
except where noted below. More than one option may be used.
Entered: AP Engineer: MAM Sales: RWM Approved: JJB Spec Number:
Date: 4/2 /20 5 Date: 4/2 /20 5 Date: 4/2 /20 5 Date: 4/2 /20 5 60172
1
1
2
2
A A
B B
CODE
IDENT. NO.
52681
DWG. NO.
SCALE: SHEET
DRAWN CHECKED ENGINEER
TITLE
UNLESS OTHERWISE SPECIFIED TOLERANCES ARE:
DIMENSIONS IN MILLIMETERS
[ IN BRACKETS ]
XX ±0.13
ANGLES 2 DEGREES
3425 WALDEN AVE. DEPEW, NY 14043
(716) 684-0001 E-MAIL: [email protected]
DIMENSIONS IN INCHES
DECIMALS XX ±.01
ANGLES 2 DEGREES
FILLETS AND RADII
.003 - .005
DECIMALS X ± 0.3
FILLETS AND RADII
0.07 - 0.13
INSTALLATION DRAWING
10943
1 OF 13.5X
MECHANICALLY FILTERED
SHOCK ACCELEROMETER
XXX ±.005
BB 4/20/15 ECB 4/20/15 MAM 4/20/15
10943
PCB Piezotronics Inc. claims proprietary rights in
the information disclosed hereon. Neither it nor any
reproduction thereof will be disclosed to others
without the written consent of PCB Piezotronics Inc.
10-32 UNF - 2A
1.15 [29.3]
.91 [23.0]
.20 [5.1]
.37 [9.4]Ø
1/4-28 UNF - 3A
.02 [0.5]
.375 [9.52] HEX 1
REVISIONS
REV DESCRIPTION DIN
A UPDATED MAIN ASSEMBLY 43883
A
.013 [.33] A
.001 [.03]
63 [1.6]
MOUNTING HOLE PREPARATION
Ø.213 [Ø5.41] .30 [7.6] MIN.
1/4-28 UNF-3B .20 [5.1] MIN.
1RECOMMENDED MOUNTING TORQUE ON .375 [9.52] HEX 2.4-4 FOOT
POUNDS (2.8-3.4 NEWTON METERS).

This manual suits for next models

1

Other PCB Piezotronics Accessories manuals

PCB Piezotronics 206C User manual

PCB Piezotronics

PCB Piezotronics 206C User manual

PCB Piezotronics 010M144 User manual

PCB Piezotronics

PCB Piezotronics 010M144 User manual

PCB Piezotronics 357C10/NC User manual

PCB Piezotronics

PCB Piezotronics 357C10/NC User manual

PCB Piezotronics 2508-04A User manual

PCB Piezotronics

PCB Piezotronics 2508-04A User manual

PCB Piezotronics J357B02 User manual

PCB Piezotronics

PCB Piezotronics J357B02 User manual

PCB Piezotronics 224C User manual

PCB Piezotronics

PCB Piezotronics 224C User manual

PCB Piezotronics 333B30 User manual

PCB Piezotronics

PCB Piezotronics 333B30 User manual

PCB Piezotronics 353B02 User manual

PCB Piezotronics

PCB Piezotronics 353B02 User manual

PCB Piezotronics M215B User manual

PCB Piezotronics

PCB Piezotronics M215B User manual

PCB Piezotronics ICP W112A21 User manual

PCB Piezotronics

PCB Piezotronics ICP W112A21 User manual

PCB Piezotronics 356B20/NC User manual

PCB Piezotronics

PCB Piezotronics 356B20/NC User manual

PCB Piezotronics 101A02 User manual

PCB Piezotronics

PCB Piezotronics 101A02 User manual

PCB Piezotronics S111A22 User manual

PCB Piezotronics

PCB Piezotronics S111A22 User manual

PCB Piezotronics 353B12 User manual

PCB Piezotronics

PCB Piezotronics 353B12 User manual

PCB Piezotronics 112A03 User manual

PCB Piezotronics

PCB Piezotronics 112A03 User manual

PCB Piezotronics 1403-11A User manual

PCB Piezotronics

PCB Piezotronics 1403-11A User manual

PCB Piezotronics 351B04 User manual

PCB Piezotronics

PCB Piezotronics 351B04 User manual

PCB Piezotronics IMI SENSORS EX642A12 User manual

PCB Piezotronics

PCB Piezotronics IMI SENSORS EX642A12 User manual

PCB Piezotronics IMI SENSORS HT646B02 User manual

PCB Piezotronics

PCB Piezotronics IMI SENSORS HT646B02 User manual

PCB Piezotronics IMI SENSORS HT641B02 User manual

PCB Piezotronics

PCB Piezotronics IMI SENSORS HT641B02 User manual

PCB Piezotronics 108A02 User manual

PCB Piezotronics

PCB Piezotronics 108A02 User manual

PCB Piezotronics N200C20 User manual

PCB Piezotronics

PCB Piezotronics N200C20 User manual

PCB Piezotronics 102M81A User manual

PCB Piezotronics

PCB Piezotronics 102M81A User manual

PCB Piezotronics PCB-(M)353B17 User manual

PCB Piezotronics

PCB Piezotronics PCB-(M)353B17 User manual

Popular Accessories manuals by other brands

Honeywell C7632A Product data

Honeywell

Honeywell C7632A Product data

socomec TF Series quick start

socomec

socomec TF Series quick start

e-conolight e-acp Series installation instructions

e-conolight

e-conolight e-acp Series installation instructions

Atlona OmniStream 238 installation guide

Atlona

Atlona OmniStream 238 installation guide

IKEA VARMFRONT manual

IKEA

IKEA VARMFRONT manual

CS Instruments VA 500 instruction manual

CS Instruments

CS Instruments VA 500 instruction manual

Campbell TE525 instruction manual

Campbell

Campbell TE525 instruction manual

elero Unio-868 INFORMATION FOR USE

elero

elero Unio-868 INFORMATION FOR USE

Maxon TruTalk TK514 manual

Maxon

Maxon TruTalk TK514 manual

Hioki SP7150 instruction manual

Hioki

Hioki SP7150 instruction manual

Immergas 3.030906 Instruction and warning book

Immergas

Immergas 3.030906 Instruction and warning book

Meari Bell 7S quick guide

Meari

Meari Bell 7S quick guide

CKD PPX Series manual

CKD

CKD PPX Series manual

TREND TBTS installation instructions

TREND

TREND TBTS installation instructions

Dwyer Instruments MFS Series Installation and operating instructions

Dwyer Instruments

Dwyer Instruments MFS Series Installation and operating instructions

Network Thermostat NetX NT-DRS installation manual

Network Thermostat

Network Thermostat NetX NT-DRS installation manual

IFM Electronic Efector 200 Training manual

IFM Electronic

IFM Electronic Efector 200 Training manual

WATTECO Modbus Class A 50-70-080 quick start guide

WATTECO

WATTECO Modbus Class A 50-70-080 quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.