PEAKnx Controlmini User manual

V 1.3.2
Controlmini
User manual
EN

User manual, Controlmini
Product Item number
Controlmini PNX12-10001
The product names mentioned in this document may be brands or registered trademarks
of their respective owners. These are not explicitly labeled with “™” or “®”.
© PEAKnx GmbH
Otto-Röhm-Strasse 69
64293 Darmstadt
Germany
www.peaknx.com
Document version: 1.3.2
Date: 30.07.21
This user manual contains the most important information for
operating the Controlmini in a safe manner. Please study this
manual carefully before working with the device. This applies to
all persons who come into contact with the device.

User manual, Controlmini
Warning symbols and signal words used in this manual
Warning Obey warning to avoid death or serious injury
Caution Obey instructions to avoid personal injury or damage to property
Note Instructions and facts to be followed
Tip Additional, useful hints
Important safety instructions, please read before installation!
Warning
The device can carry dangerous voltages if improperly installed!
▪Installation and commissioning may only be carried out by specially trained personnel
(qualified electricians).
Caution
Avoid damage to the panel!
▪Only use the panel in perfect condition, as well as in accordance with its intended use,
in a way that is safe and aware of the hazards and in compliance with this manual!
▪Do not make any changes, attachments or conversions to the device without the
manufacturer’s permission!
▪In particular, have faults that could impair safety immediately eliminated!

User manual, Controlmini
Table of Contents
Warning symbols and signal words used in this manual 3
Important safety instructions, please read before installation! 3
1 Target audience 6
2 Intended use 6
3 Product description 7
3.1 Software 7
3.1.1 Operating system 7
3.1.2 Operation with the PEAKnx software YOUVI 7
3.1.3 Operation with third-party software 8
3.2 Product features 8
3.3 Device components I: Flush-mounted version 9
3.4 Device components II: Wall-mounted version 10
3.5 Touch panel, front view 11
3.6 Touch panel, rear view 12
3.7 Notes on the panel‘s ports 13
3.7.1 KNX terminals 13
3.7.2 Power supply 13
3.7.3 Ethernet port 13
3.7.4 Connections for external mouse and keyboard 13
3.8 Controls 13
3.8.1 Graphical user interface 13
4 Delivery 14
5 Important safety and handling information 15
6 Installation and start-up 15
6.1 Preparation 16
6.2 Flush-mounted installation 16
6.2.1 Installation in brickwork 16
6.2.2 Installation in a cavity wall 17
6.3 Connecting the power supply 17
6.3.1 Prepare the voltage source for the DIN rail (recommended) 17
6.3.2 Using a power supply unit in the flush-mounted box 17
6.4 Connecting and mounting the panel 19
7 Initial commissioning and operation 20
7.1 Switching the Controlmini on and o 21
7.2 Activate keyboard input 21
7.3 Setting up the visualization 21
8 Maintenance 22
8.1 Cleaning the touchscreen 22
9. Troubleshooting 23
9.1 Touch panel stops responding 23
9.1.1 Turning the panel o and back on 23
Page

6
User manual, Controlmini
1 Target audience
These instructions are intended to explain basic aspects of the installation, commissioning, ope-
ration and maintenance of the Controlmini. Depending on the use phase, this manual is aimed
at other target groups:
Commissioning
▪Installation and commissioning may only be carried out by qualified electricians and system
integrators. Basic knowledge of electrical and KNX installation is assumed.
Operation
▪The operation of the commissioned panel is explained for unskilled users.
Repair
▪Under no circumstances carry out repairs to the unit yourself! If damage should occur to the
device, please contact our technical support immediately, see 9.3 Technical support.
2 Intended use
Depending on the software used, the Controlmini serves as control unit for the entire KNX
installation across rooms. It thus also serves as a status display. The device must be operated
within the scope of the technical data and instructions given in this manual. Keep the device
away from moisture, dirt and dust to prevent damage to the device.
The following applications belong to the intended use:
▪Use as an operating panel (input via touch) for KNX-controlled devices
▪Intercom station for compatible door stations
− A list of all compatible door stations can be found in our FAQ:
www.peaknx.com/en/FAQ under the topic “compatibility”.
▪Indoor operation, note the ambient conditions, see 10 Technical data
The following applications are not part of the intended use:
▪Operation in systems requiring special monitoring, in safety-relevant areas or in hazardous
areas
▪Operation under ambient conditions that do not comply with the specifications regarding
temperature and air humidity. These include
− Outdoor operation
− Operation under direct sunlight
− Operation in environments with high dust and dirt exposure
− Operation in environments with high vibration exposure
▪Operation in a moving environment (e.g., mobile homes)
▪Operation in vessels

7
User manual, Controlmini
▪Operation of the device by small children
▪Unauthorized repairs or changes to the device
3 Product description
The Controlmini (short: panel) is a high-quality panel computer for wall mounting. It serves as a
display and control unit for the KNX controlled components and installations of a building.
3.1 Software
The panel can be operated both with the supplied YOUVI software and with other Windows-
compatible software.
Note: PEAKnx provides no service and no warranty for software products from other com-
panies as well as in case of OS driver updates.
3.1.1 Operating system
The operating system used is Microsoft Windows 10 IoT Enterprise LTSC. All components requi-
red for the unit to function have been pre-installed. To activate functions such as write protec-
tion, the preinstalled Tectool can be used. Further instructions and drivers can be downloaded
from www.peaknx.com in the download area. Other programs for the visualization of building
information and for building control can be installed later.
3.1.2 Operation with the PEAKnx software YOUVI
The YOUVI Basic visualization software included in the scope of delivery is used to control KNX
devices such as sockets, switches, lights, dimmers, RGB lights, heaters, blinds, and shutters.
Thanks to the IP router included in the software package, the panel can run YOUVI’s visualiza-
tion without an external server or additional bus coupler. Only the connection to the IP network
and the KNX bus (via the integrated KNX connection on the panel) is necessary. In addition to
visualization and IP router, a bus monitor is also included in the scope of delivery, which can
record and filter the KNX trac.
In addition to the basic functions for controlling KNX devices, YOUVI can be extended via mo-
dules for IP camera connection, creation of logics, control via app on the road or voice control.
All current modules are available in the shop at www.peaknx.com > Shop > Software > YOUVI.
Note: For the YOUVI installation, please pay special attention to the YOUVI quick reference
guide and the information on KNX project preparation to enable the automatic reading of the
project. This quick reference guide is included in the delivery.

8
User manual, Controlmini
For more information about YOUVI, see the YOUVI Help which you can access in YOUVI under
the “?”-icon. Here, you will also find the current range of functions of the software under: Visu-
alization > Scope of functions.
3.1.3 Operation with third-party software
The Windows 10 LTSC operating system pre-installed on the panel allows the use of other
Windows-based software for e.g., visualizations and door intercoms. Depending on the software
used, the functional scope of the panel can be expanded considerably. A list of compatible soft-
ware can be found in the FAQs:
www.peaknx.com/en/FAQ, topic “compatibility”.
Further instructions such as for setting up the panel as a door station can be found in the down-
load area: https://www.peaknx.com/de/downloads.
3.2 Product features
▪LED Backlit full color TFT display, 1920 x 1080 pixels
▪Touchscreen, projected capacitive (PCAP)
▪Integrated speakers and microphone
▪Integrated camera
▪Fieldbus connection for KNX
▪100 Mbit-Ethernet connection, suitable standard for cabling: Cat-5 or better
▪Operating system: Windows 10 IoT Enterprise LTSC
▪No fan, thus silent
▪24 V DC supply; 2,5 A
▪Maximum power consumption under full load: 15 W
▪Power consumption, no load: 10 W, Server operation without LCD: 5W
▪Ambient temperature 0 to 35 °C
▪flush-mounted or surface-mounted wall installation, in landscape orientation, parallel to the
wall
▪Protection class IP20

9
User manual, Controlmini
3.3 Device components I: Flush-mounted version
Position Description
A1 Flush-mounted box
A2 Panel with touchscreen
A3 Glass cover

10
User manual, Controlmini
3.4 Device components II: Wall-mounted version
Position Description
B1 Wall-mounted frame
B2 Panel with touchscreen
B3 Glass cover

11
User manual, Controlmini
3.5 Touch panel, front view
Position Description
C1 4 x Intake for glass cover
C2 On/O button
C3 4 x screw holes for fixing the panel
C4 Volume up/down button
C5 Microphone
C6 WLAN antenna
C7 Camera
C8 2 x USB 2.0
C9 Touchscreen
C10 Windows Homebutton

12
User manual, Controlmini
3.6 Touch panel, rear view
Position Description
D1 100 Mbit Ethernet port
D2 2 x KNX-Wago 243-211 installation terminal
D3 Mini HDMI
D4 Micro SD slot
D5 USB 3.0
D6 Panel power supply: 24 V DC
D7 Panel power supply: GND

13
User manual, Controlmini
3.7 Notes on the panel’s ports
3.7.1 KNX terminals
A terminal of the following specification is used for the KNX connection:
KNX WAGO 243 211, conductor diameter: 0.6 - 0.8 mm.
Note: The KNX fieldbus can only be used with PEAKnx software.
Note: The device cannot be used as a line coupler for KNX lines!
3.7.2 Power supply
The plug-in terminal for the voltage supply is designed for a conductor cross-section (rigid) from
0.14 mm² to 1.5 mm². The conductor cross-section (flexible) with wire end ferrule without plastic
sleeve must be in the range of 0.25 mm² to 1.5 mm².
3.7.3 Ethernet port
Note: A cable of category CAT5e is recommended for using the 100 Mbit LAN connection.
3.7.4 Connections for external mouse and keyboard
To connect additional controls to the panel, such as an external mouse or keyboard, a USB
port is available at the back of the panel. There are two additional USB ports on the panel front
under the glass cover, for example to use a USB adapter for a wireless keyboard and mouse, or
to transfer data onto the panel.
Caution
Avoid overheating of important panel components!
▪Avoid prolonged use of power-intensive devices on the USB port

14
User manual, Controlmini
3.8 Controls
Caution
Avoid danger of injury from falling parts!
▪Ensure that small children do not have access to the magnetically adhering front glass
and can’t accidentally loosen it.
3.8.1 Graphical user interface
Touch the panel to operate. A brief touch of the panel is interpreted as a mouse click. A right
mouse click is obtained by a prolonged touch (approx. 3 seconds).
Text entries can be made using the Windows on-screen keyboard. This can be found in the
task bar at the bottom right. If you swipe from the right side of the screen, you can also switch
to tablet mode in the menu that appears so that the keyboard appears automatically when you
type in a text box.
Caution
Avoid damage to front glass and display!
▪Do not use the touch screen with sharp or pointed objects.
4 Delivery
▪Controlmini panel
▪USB flash drive: YOUVI Basic software package, Controlmini user manual
▪Brief instructions for commissioning the panel and software
▪Network connector
▪Network patch cable
Optionally included in scope of delivery:
▪Glass cover
▪Flush-mounted box or surface-mounted frame
▪Recovery USB Flash Drive
▪Controlmini power supply unit for the switch cabinet (recommended) or flush-mounted box

15
User manual, Controlmini
5 Important safety and handling information
Warning
The panel may only be installed and commissioned by qualified electricians!
Warning
Observe the national regulations applicable in your country regarding installation, func-
tional testing, repair, and maintenance of electrical products!
▪Observe the “Five Safety Rules” (DIN VDE 0105, EN 50110) and apply them correctly:
− Disconnect mains
− Prevent reconnection
− Test for absence of harmful voltages
− Ground and short circuit
− Cover or close o nearby live parts
▪Before installation, make sure that all connecting cables of the device are undama-
ged.
Caution
Avoid overheating of important panel components!
▪The panel may only be installed in landscape format and parallel to the wall to ensure
ventilation of the computer in the panel by convection.
6 Installation and start-up
The Controlmini can be mounted to the wall both flush (flush-mounted box PNX12-10004) and
surface-mounted (surface-mounted frame PNX12-10005). Furthermore, it is possible to mount
the Controlmini with a suitable adapter frame on various flush-mounted boxes of other manu-
facturers.

16
User manual, Controlmini
Further instructions for mounting the surface-mounted version or fixing with the help of adap-
ters are supplied with the respective surface-mounted frame or adapter.
6.1 Preparation
Note: We recommend hedging the panel, since in rare cases the panel must be taken com-
pletely from the power supply, see section 9.1.2 Disconnecting the panel from the power supply
Necessary accessories for the installation of the panel:
▪Flush-mounted box (PNX12-10004) or surface-mounted frame (PNX12-10005)
▪Glass cover
▪Power supply unit 24 V DC for DIN rail (PNX12-10010) (recommended)
or
▪Power supply unit 24 V DC for the flush-mounted box (PNX12-10011)
6.2 Flush-mounted installation
Tip: Choose the installation height of the panel according to the height of the primary user
so that the top edge of the panel is at his/her eye level. A slightly lower screen prevents fatigue
of the arms during operation.
6.2.1 Installation in brickwork
1. Make a recess of H x W x D: 194 x 252 x 50 mm in the wall. Therefore, use the template
provided. The flush-mounted box must later be flush with the wall.
2. Depending on the cable position, press the circular plates at the top or bottom out of the
box and insert the supplied self-sealing grommets to prevent damage to the cable.
3. When inserting the flush-mounted box, route the supply and communication cables (Ether-
net, KNX) through dierent holes in the flush-mounted box to avoid possible interference.
4. Use the template as a splash guard during the filling of the edges.

17
User manual, Controlmini
6.2.2 Installation in a cavity wall
1. Make a recess of H x W: 194 x 252 mm in the wall. Therefore, use the template supplied. The
flush-mounted box must later be flush with the wall.
2. Glue or screw the two wooden blocks supplied into the cavity wall.
3. Depending on the cable position, press the circular plates at the top or bottom out of the
box and insert the supplied self-sealing grommets to prevent damage to the cable.
4. When inserting the flush-mounted box, route the supply and communication cables (Ether-
net, KNX) through dierent holes in the flush-mounted box to avoid possible interference.
5. Screw the flush-mounted box on the sides to the wooden blocks using the four screws.
6. Use the template as a splash guard during the filling of the edges.
6.3 Connecting the power supply
Warning
Avoid electric shock when touching live parts!
▪Disconnect all associated circuit breakers before working on the device.
▪Cover live parts in the surroundings.
6.3.1 Prepare the voltage source for the DIN rail (recommended)
▪Use a power source of the following specification:
− 24 V DC, 2,5 A for the control cabinet, Item number: PNX12-10010
▪Connect the cable wires of the power supply unit with the pluggable screw terminal included
in the scope of delivery. Please pay attention to the polarity.
6.3.2 Using a power supply unit in the flush-mounted box
Particularly, when replacing a foreign device with the Controlmini, a power supply is often
already present in the flush-mounted box. This means that mains voltage and low voltage are in
the same housing and if connected incorrectly, even parts that normally only carry low voltage
unintentionally carry mains voltage.

18
User manual, Controlmini
Warning
Avoid touching dangerous voltages in the event of a fault!
▪Installation may only be carried out by qualified electricians!
▪Check that there is no voltage before starting work!
▪Route cables so that low voltage wires are dependably protected against mains
voltage.
1. Place the power supply unit (PNX12-10011) in the flush-mounted box.
2. Connect the 24 V side of the power supply unit with the plug-in screw
terminal included in the scope of delivery. Please pay attention to the
polarity.
3. Connect the mains cable to the 230 V side of the power supply unit.
4. Grounding
− When using a power supply unit in the flush-mounted box of the Controlmini:
− Connect the grounding in the flush-mounted box. Use the supplied grounding set:

19
User manual, Controlmini
− When using a power supply unit in a third-party flush-mounted box:
− Connect the earthing to the panel. Use the earthing set provided for this purpose:
6.4 Connecting and mounting the panel
Preparation
▪Place the screws (M3x12) included in the scope of delivery within reach for fixing the panel
within the flush-mounted box.
▪For further notes on the panel’s ports, please read section 3.7 Notes on the panel’s ports
Connection of the panel
5. Connect the Ethernet cable to the panel (D1).
6. Plug the KNX cable with the colors red (+) and black (-) into the KNX-terminal 1 (D2), as indi-
cated on the panel.
7. Push the prepared 24 V connector terminals into the appropriate connectors in the panel
(D6 and D7). Pay attention to the polarity.

20
User manual, Controlmini
Fastening the panel
8. Install the panel in the flush-mounted box. Therefore, use the four coun-
tersunk screws (M3x12) for fixing it in the corresponding holes (C3).
9. Place the glass cover with the magnetic holders into the four intakes (C1)
provided and continue until the glass rests against all four corners of the
touch screen.
10. Ensure that the opening for the camera is positioned on the upper
screen.
7 Initial commissioning and operation
Caution
Avoid damage to the panel due to early commissioning!
▪Note the climatic conditions at the installation site!
▪Before switching on the mounted device, the device must have adapted to the clima-
tic conditions at the installation site.
▪Temperature and humidity dierences can cause damage to the unit.
Tip: After commissioning and setting up the panel, we recommend that you create a back-
up using the optionally available recovery USB flash drive from PEAKnx. Further instructions
can be found in the corresponding Quick Start Guide.
Caution
Avoid damage to the glass cover and display!
▪The touch-sensitive surface can easily be damaged! Use only your fingers or a touch-
pen to operate the panel. Do not use sharp or pointed objects.
7.1 Switching the Controlmini on and o
Note: In the delivery state, the panel automatically logs on with the user name Controlmini
without a password. After the Login, additional users can be added at any time or further set-
tings may be changed in the Windows Settings.
Other manuals for Controlmini
5
This manual suits for next models
1
Table of contents
Other PEAKnx Touch Panel manuals