5 of 8 ISSUED: 10-31-05 SHEET #: 202-9011-2 01-29-07
Installation to Solid Concrete and Cinder Block Wall
1
CUTAWAY VIEW
INCORRECT
concrete
plaster/
drywall
AA
CORRECT
concrete
plaster/
drywall
AA
Position wall plate (AA) on wall so that upper slots are 4-5/8"
above desired center of screen. Use wall plate (AA), making
sure that it is level, as a template to mark holes. Drill four 1/4"
(6 mm) dia. holes to a minimum depth of 2-1/2" (64 mm).
Concrete must be 2000 psi density minimum. Insert anchors
(DD) in holes flush with wall as shown in figure 1.4. Place wall
plate (AA) over anchors and secure with #14 x 2-1/2" (6 mm
x 65 mm) wood screws (CC) as shown in figure 1.5. Make
sure wall plate is level and tighten all fasteners.
concrete
wall
Drill holes and insert anchors (DD)
Place wall plate (AA) over anchors and secure with
screws (CC)
Tighten all fasteners
CC
AA
1
3
2
• Tighten wood screws firmly, but do not overtighten.
Overtightening can damage the screws, greatly
reducing their holding power.
• Never tighten in excess of 80 in. • lb (9 N.M.).
WARNING
• When installing Peerless wall mounts on cinder block, verify that you have a minimum of 1-3/8" of actual concrete
thickness in the hole to be used for the concrete anchors. Do not drill into mortar joints! Be sure to mount in a solid
part of the block, generally 1" minimum from the side of the block. Cinder block must meetASTM C-90 specifica-
tions. It is suggested that a standard electric drill on slow setting is used to drill the hole instead of a hammer drill to
avoid breaking out the back of the hole when entering a void or cavity.
• Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor.
• Make sure that the supporting surface will safely support the combined load of the equipment and all attached
hardware and components.
WARNING
DD
DD
CC
fig 1.4
fig 1.5
• Concrete anchors are not intended for attachment to
concrete wall covered with a layer of plaster, drywall,
orother finishing material asshown below.Ifmounting
toconcrete wall coveredwith plaster/drywall is
unavoidable,plaster/drywall (up to5/8" thick) must be
counterboredas shown below.Be sure concrete
anchorsdo not pullaway from concretewhen tighten-
ing screws. If plaster/drywall is thicker than
5/8", custom fasteners must be supplied by installer.
WARNING
AA
DD