manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. PEERLESS
  6. •
  7. Rack & Stand
  8. •
  9. PEERLESS PLC Guide

PEERLESS PLC Guide

Other PEERLESS Rack & Stand manuals

PEERLESS SUF650P  and assembly Guide

PEERLESS

PEERLESS SUF650P and assembly Guide

PEERLESS PARAMOUNT PT640  and assembly Guide

PEERLESS

PEERLESS PARAMOUNT PT640 and assembly Guide

PEERLESS Smartmount SA752P Guide

PEERLESS

PEERLESS Smartmount SA752P Guide

PEERLESS SUF640P  and assembly Guide

PEERLESS

PEERLESS SUF640P and assembly Guide

PEERLESS IM760P Guide

PEERLESS

PEERLESS IM760P Guide

PEERLESS A100IWBMOUNT Guide

PEERLESS

PEERLESS A100IWBMOUNT Guide

PEERLESS Smartmount Guide

PEERLESS

PEERLESS Smartmount Guide

PEERLESS SmartMount ST 635 Guide

PEERLESS

PEERLESS SmartMount ST 635 Guide

PEERLESS LCT Series Guide

PEERLESS

PEERLESS LCT Series Guide

PEERLESS PWMT300 User manual

PEERLESS

PEERLESS PWMT300 User manual

PEERLESS PARAMOUNT PP740 User manual

PEERLESS

PEERLESS PARAMOUNT PP740 User manual

PEERLESS DMU50SM Guide

PEERLESS

PEERLESS DMU50SM Guide

PEERLESS WBK100-W Guide

PEERLESS

PEERLESS WBK100-W Guide

PEERLESS WSP700 Instruction Manual

PEERLESS

PEERLESS WSP700 Instruction Manual

PEERLESS PLT BLK Guide

PEERLESS

PEERLESS PLT BLK Guide

PEERLESS SR1G Guide

PEERLESS

PEERLESS SR1G Guide

PEERLESS SPK 811W User manual

PEERLESS

PEERLESS SPK 811W User manual

PEERLESS PARAMOUNT PF640 Guide

PEERLESS

PEERLESS PARAMOUNT PF640 Guide

PEERLESS Mobile Videowall Trolley PDVWM 2x2 46 55 L Guide

PEERLESS

PEERLESS Mobile Videowall Trolley PDVWM 2x2 46 55 L Guide

PEERLESS DS-VW660  and assembly Guide

PEERLESS

PEERLESS DS-VW660 and assembly Guide

PEERLESS WSP 716 User manual

PEERLESS

PEERLESS WSP 716 User manual

PEERLESS Smartmount D-FPF-220 Guide

PEERLESS

PEERLESS Smartmount D-FPF-220 Guide

PEERLESS Paramount PF660 Guide

PEERLESS

PEERLESS Paramount PF660 Guide

PEERLESS Paramount PPF Guide

PEERLESS

PEERLESS Paramount PPF Guide

Popular Rack & Stand manuals by other brands

Dynex DX-MP3MT Quick setup guide

Dynex

Dynex DX-MP3MT Quick setup guide

Konig & Meyer 24185 manual

Konig & Meyer

Konig & Meyer 24185 manual

ECG LD 326501 instruction manual

ECG

ECG LD 326501 instruction manual

Philips SB7S19S/00 quick start guide

Philips

Philips SB7S19S/00 quick start guide

Woodline KIT-250 lb instructions

Woodline

Woodline KIT-250 lb instructions

ricoo S1222 installation instructions

ricoo

ricoo S1222 installation instructions

Kanto P301 user manual

Kanto

Kanto P301 user manual

VidaBox VB MNT FFS2 installation guide

VidaBox

VidaBox VB MNT FFS2 installation guide

PROEL PLWIN60C user manual

PROEL

PROEL PLWIN60C user manual

AllMounts PLB-43S instruction manual

AllMounts

AllMounts PLB-43S instruction manual

VMP VH-001 instruction sheet

VMP

VMP VH-001 instruction sheet

Nederman SYSTEM 920/400 instruction manual

Nederman

Nederman SYSTEM 920/400 instruction manual

Glasdon ORBIS POST MOUNTING KIT installation guide

Glasdon

Glasdon ORBIS POST MOUNTING KIT installation guide

Songmics LGR105 manual

Songmics

Songmics LGR105 manual

Grape GM401 user manual

Grape

Grape GM401 user manual

FourStarGroup 11225296 manual

FourStarGroup

FourStarGroup 11225296 manual

CHIEF FLR100 installation instructions

CHIEF

CHIEF FLR100 installation instructions

FEC XDCAM EX PMW-EX30 manual

FEC

FEC XDCAM EX PMW-EX30 manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

ISSUED:10-19-01 SHEET #: 200-9264-3 07-26-04
1 of 4
Visit the Peerless Web Site at www.peerlessindustries.com For customer service call 1-800-729-0307 or 708-865-8870.
H
I
G
L
description qty. part #
Asupport arm retainer 1 590-1007
Badapter 1 590-1009
Cceiling support arm 1 100-1001
Dcover plate 1 100-1006
Eceiling arm box 1 100-1005
Ftilt hook box 1 200-1552
GM10 x 1.5 x 15 mm penta-pin screw 8 520-9263
Hretainer pin (long) 1 5M9-025-X02
Iretainer pin (short) 1 560-9643
Note: some parts may not appear exactly as illustrated.
Parts List: Secure Ceiling Mount
IMPORTANT: If you will install an extension
column, DO NOT INSTALL THIS PIPE. Begin with
step 2.
Thread threaded, notched pipe (J) into threaded fitting
in ceiling plate (M). Tighten four or five complete turns
leaving slot aligned with one small hole in the side of
the ceiling plate (M) threaded fitting. Insert and tighten
one M5 x .8 x 1 penta-pin™screw (O) as shown. Use
the small penta-pin tool (Q) and a 1/4" driver to drive
screw (O).
description qty. part #
Jthreaded notched pipe 1 200-0008
Kadhesive vinyl (not shown) 1 600-1004
L#14 x 2.5 wood screw 4 5S1-015-C03
Mceiling plate 1 128-1039
Nceiling plate end cap 2 2PT-22CA01D
OM5 x .8 x 10 penta-pin screw 3 505-9010
Ppenta-pin tool™(large, not shown) 1 520-9260
Qpenta-pin tool (small, not shown) 1 520-9249
C
B
E
J
F
A
MD
N
1
O
threaded
fitting
penta-pintool
J
O
Before you start check the parts list below to make sure all of the parts listed are included.
Installation and Assembly - Secure Ceiling Mount Model: PLC
IMPORIMPOR
IMPORIMPOR
IMPORTT
TT
TANT!ANT!
ANT!ANT!
ANT! Read entire instruction sheet
before you start installation and assembly. IMPORIMPOR
IMPORIMPOR
IMPORTT
TT
TANT!ANT!
ANT!ANT!
ANT! Installer must verify that the
ceiling will safely support the combined weight
of the screen and mounting hardware.
This product must be
installed by a qualified,
professional installer.
R
M
ISSUED:10-19-01 SHEET #: 200-9264-3 07-26-04
2 of 4
Visit the Peerless Web Site at www.peerlessindustries.com For customer service call 1-800-729-0307 or 708-865-8870.
For Wood Joist Finished Ceiling, Exposed Wood
Joists, or Wood Beam Ceiling. (See step 3for
concrete ceilings). Drill four 5/32" (4 mm) dia. holes to a
minimum depth of 2.5" (64 mm) INTO JOIST CENTERS.
Attach ceiling plate (M) with four #14 x 2.5" wood
screws (L) using a 3/8"(10 mm) socket wrench.
Snap end caps (N) into place.
2
For Concrete Ceilings drill four 5/16" (8 mm) dia.
holes to a minimum depth of 1 3/4" (45 mm). Attach
ceiling plate (M) using concrete expansion anchors as
shown in 3-1 thru 3-4. Then snap end caps (N) into
place.
Align hole in ceiling plate with hole in ceiling.
Gently hammer in concrete anchor.
Use a 10 mm wrench to tighten concrete anchors
to 80 in. lb (9 N.M.) maximum torque to expand anchors.
3-1
3-2
3-3
3-4
• It is the responsibility of the installer to verify that the
ceiling will safely support the combined load of all
attachedhardwareandcomponents.
WARNING
N
M
N
M
3
• Always attach concrete expansion anchors directly to
load-bearingconcrete.
• Neverattachconcrete expansion anchors toconcrete
coveredwithplaster, drywall, or otherfinishingmaterial.
WARNING
• Tighten wood screws (L) so that ceiling plate (M) is
firmlyattached,butdonotovertighten. Overtightening
candamagescrews, greatly reducing theirholding
power.
• Never tighten in excess of 80 in. lb. (9 N.M.).
• Makresure that mounting screws are anchored into
the center of the joist. The use of an "edge to edge"
studfinderis highly recommended.
WARNING
L
3-1 3-2
FOR PRODUCT SAFETY USE ONLY RAWLTM #5005 OR
HILTITM HL814 CONCRETE ANCHORS. Order accessory
kit #ACC210 which contains four .312 x 1.625 (8 mm x
41 mm) concrete expansion anchors.
ISSUED:10-19-01 SHEET #: 200-9264-3 07-26-04
3 of 4
Visit the Peerless Web Site at www.peerlessindustries.com For customer service call 1-800-729-0307 or 708-865-8870.
Thread adapter (B) onto end of threaded, notched
pipe (J) (or, for extension column applications, onto
end of extension column). Tighten securely, four or
five complete turns, making sure that one of the slots
in the end of pipe (J) aligns with small threaded hole
in the side of adapter (B). Insert and tighten one M5 x
BY HAND, insert four M10 x 1.5 x 15 mm penta-pin screws (G) into
threaded holes in the sides of ceiling arm box (E). Leave approxi-
mately 1/4" of exposed thread. Slide ceiling arm box (E) onto end of
ceiling support arm (C). Insert LONG retainer pin (H) into end of ceiling
support arm (C). Retainer pin (H) must engage slot on bottom of
ceiling arm box (E) as pictured. Attach cover plate (D) using one M5 x
.8 x 1 penta-pin screw (O). Attach using small penta-pin tool (Q) and
a 1/4" driver.
Slide adapter (B) onto end of ceiling support arm (C).
Insert support arm retainer (A) into end of ceiling
support arm (C). Insert SHORT retainer pin (I). Note: A
gentle tap with a hammer may be necessary to drive
retainer pin (I) into support arm retainer (A).
4
B
C
K
1/4”
G
O
I
J
B
C
E
H
A
G
H
E
C
O
D
MM
.8 x 1 penta-pin screw (O) using small penta pin tool (Q) and a 1/4"
driver. OPTIONAL: Wrap adhesive vinyl (K) around exposed threads
of pipe (J) for a cleaner finished assembly.
E
ISSUED:10-19-01 SHEET #: 200-9264-3 07-26-04
4 of 4
Visit the Peerless Web Site at www.peerlessindustries.com For customer service call 1-800-729-0307 or 708-865-8870.
Hang tilt hook box (F) onto ceiling arm box (E). Adjust
tilt as desired and tighten four M10-1.5 x 15 mm penta-
pin screws (G) securely using large penta-pin tool (P)
and a 1/4” driver.
F
E
G
Attach tilt hook box (F) to adapter plate (AA) using four screws (G). Tighten
using large penta-pin tool (P) and a 1/4" driver.
G
AA
F
Note: Refer to accompanying instruction sheet for attachment of adapter plate to screen before proceeding with step 5.
5
6
©2004PeerlessIndustries,Inc. Allrightsreserved.
PeerlessisaregisteredtrademarkandPenta-pinisatrademarkofPeerlessIndustries,Inc.
Allotherbrandandproductnamesaretrademarksorregisteredtrademarksoftheirrespectiveowners.
• For a safe assembly be sure to fully tighten four
screws(G).
WARNING