
5
DO NOT operate the stove if the flame becomes dark and sooty or if the firepot overfills with pellets. Push
the OFF Touch Pad and inspect the heater. (See Operating Your Stove). Soot or creosote may accumu-
late in the exhaust vent system when the stove is operated under incorrect conditions such as an ex-
tremely rich burn. The flame will have a lazy orange color with black tips. This indicates poor pellet fuel
combustion.
NEVER block free airflow through the open vents of the unit. The viewing door and ash pan must be
closed and latched during operation.
The pellet appliance exhaust system works with negative combustion chamber pressure and a positive
chimney pressure, therefore the exhaust system must be completely airtight and properly installed. All
exhaust system vent joints must be sealed, gas tight, with HI-TEMP RTV silicone sealant, and/or at least
3 sheet metal screws per joint and to the heater also.
Your heater requires periodic maintenance and cleaning (Refer to ”Routine Cleaning” section of the
manual). Failure to maintain your heater may lead to smoke spillage in your home.
Disconnect the power cord from the electrical outlet before performing any maintenance. Pushing ”OFF”
Touch Pad does not disconnect all power to the heater.
BEFORE carrying out any maintenance or cleaning, allow the heater to cool. Ashes must be disposed in a
metal container with a tight lid and placed on a non-combustible surface or on the ground, well away from
all combustible materials, pending final disposal.
The exhaust system should be checked twice a year minimum for any build-up of soot or
creosote. Do not touch the hot surfaces of the heater.
S
SAFETY
AFETY
T
TESTING
ESTING
NOTE: Canadian Comfort Industries grants no warranty, implied or stated, for the installation or
maintenance of your appliance, and assumes no responsibility of any consequential damage(s).
In accordance with the procedures and specifications listed in UL1482–00 & ASTM E 1509-04, and
ULC-S627-00 and ULC-S628-M93 for solid fuel room heater. Tested and listed for use in Manufactured
Homes in accordance with Oregon Administrative Rules 814-23-900 through 814-23-909. The Canadian
Comfort Industries pellet stove has been independently tested and listed by INTERTEK (an accredited testing
laboratory) to UL, ULC and CSA standards. It is tested and listed for residential installation according to current
national and local building codes as:
A Freestanding Room Heater
A Mobile Home Heater.
Fireplace Insert
Built-in Insert
A Hearth Stove
The Safety Listing Label is located on the rear
inspection panel for model FPP, and on the
hopper panel for model IPP. Please read the
label carefully. It contains important information
about installation and operation of your
pellet appliance.
Note: Your STOVE’S serial number is located
on the safety label. Your appliance serial number
is preceded by a “WH-“ (example WH-00000).
(see diagram)
PelPro Appliances www.pelprostoves.com 5
DONOTREMOVE ORCOVERTHISLABEL
LISTED PELLET BUR NING ROOM HEATER/FIREPLACE INSERT POÊLE HOMOLOGUÉ AUTONOM E/ E NCAS TRAB LE À COMBUSTIBLES SOLI DES CONV ENA N T
ALSO FOR USE I N MOB I LE HOMES ÉGALEM ENT POUR INSTALLATION DANS LES MAISONS MOBILES.
CCI MODELS:/MODÈLES: [ ] FGB [ ] IGB [ ] FPP [ ] IPP
OP TIO NS: CCI-I-3HZ & CCI 1-3VL BUILT IN FIR EPLACE KIT S / CON STRUIT DANS DE S KITS DE CHEMINEE
OPTIONS: CCI-MFBG MULTI-FUEL BURN GR ATE / CCI-MFBG
TESTED PER UL 1482-00, ASTM E 1509-04, ULC S627-00, ULC S628-M93,
THIS PELLET BURNING APPLIANCE HAS BEEN TESTED AND LISTED FOR USE IN MANUFACTURED HOMES IN
ACCORDANCE WITH OREGON ADMINISTRATIVE R ULES 814-23-900 THROUGH 814-23-909.
A
B
UNIT
UNIT
CUNIT
FLOOR
PROTECTOR
E
B
B
AD
F
BBA
B
UNIT
ALCOVE
B
B
INSTALL AND USE ONLY IN AC CO R DANCE WIT H MANUFACT URER’S INSTALLATIO N AN D OP ERATING INSTR UCTI ONS.
------- ----- ----- ----- ----- ----- ----- ----- ---- ------- ----- ----- ----- ----- ----- ----- ----- ---- ------- ----- ----- ----- ----- ----- -----
CONTACT LOCAL BUILDING OR FIR E OFF ICI ALS T O OBTAIN A PERMIT AND INFORMATIO N ON ANY INSTALLATI ON
REQUIREMENT S A ND INSTALLATI ON INSPECTIO N IN YOUR AR EA.
------- ----- ----- ----- ----- ----- ----- ----- ---- ------- ----- ----- ----- ----- ----- ----- ----- ---- ------- ----- ----- ----- ----- ----- --- ---
WARNING: DO NOT INSTALL APPLIANCE IN A SLEEPING ROOM.
------- ----- ----- ----- ----- ----- ----- ----- ---- ------- ----- ----- ----- ----- ----- ----- ----- ---- ------- ----- ----- ----- ----- ----- -----
FOR USE WITH 1/4. (6 MM) – 3/8’ (10MM) PELLETIZED WOOD FUEL.
MAX. INPUT RATING APPROXIMATELY 4.5 – 5 LB.’S PER HOUR USING 8,500 - 8,770 BTU/LB OF PELLET FUEL
ALSO FOR USE WITH SHELLED CORN AND WHEAT, UNDER 14% MOISTURE, USING MULTI-FUEL GRATE SYSTEM
MAX. INPUT RATING APPROXIMATELY 6.5 – 7 LB.’S PER HOUR
USE OF OTHE R F UEL MAY DAMAGE UNIT AND C AUSE A HAZAR DO US C ONDITION.
------- ----- ----- ----- ----- ----- ----- ----- ---- ------- ----- ----- ----- ----- ----- ----- ----- ---- ------- ----- ----- ----- ----- ----- -- --
INSTALL ON A NON-COMSUSTIBLE FLOOR PROTECTOR EXTENDING UNDER THE APPLIANCE AND 6 IN (152.4 MM)
BEYOND THE FRONT AND 6 IN (152 MM) TO EACH S I DE. DO NOT OBSTRUC T SPACE UNDER UNIT.
------- ----- ----- ----- ----- ----- ----- ----- ---- ------- ----- ----- ----- ----- ----- ----- ----- ---- ------- ----- ----- ----- ----- ----- --- ---
INSTALL AND USE ONLY IN A CODE COMPLY IN G MASONRY OR LI S TED FACTORY- BUILT FIR E PLAC E. DO NOT
REMOVE BRICKS OR MORTAR FROM MASONRY FIREPLACE, USE A NON-COMBUSTIBLE FLOOR PROTECTOR
EXTENDING BENEATH AND 6 INCHES TO THE FRONT OF THE UNIT. MUST ALSO INCLUDE A CHIMNEY LINER MEETING
TYPE HT REQUIREMENTS (2100 F) PER UL1777(US) OR ULC 8635 (CND).
------- ----- ----- ----- ----- ----- ----- ----- ---- ------- ----- ----- ----- ----- ----- ----- ----- ---- ------- ----- ----- ----- ----- ----- ----- --
DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE
------- ----- ----- ----- ----- ----- ----- ----- ---- ------- ----- ----- ----- ----- ----- ----- ----- ---- ------- ----- ----- ----- ----- ----- ----- --
VENTING SYSTEM: TYPE PL. VENTING SYSTEM MUST BE USED. CLEARANCES FROM THE P L VENT ARE AS PER THE
VENT SYS TEM MA NUFACTURER’S I NST R UCTIONS. SEE LOCAL BUILD ING CODE AND APPLIA N CE AND VEN T
MANUFACTURER’S INS TRUCTIONS FO R P RECAUTIONS REQUIRED FOR PA SS IN G VENT ING SYSTEM THR OUGH A
COMBUSTIBLE WALL OR CEILING.
------- ----- ----- ----- ----- ----- ----- ----- ---- ------- ----- ----- ----- ----- ----- ----- ----- ---- ------- ----- ----- ----- ----- ----- -----
UNDER CERTA IN CONDITIONS OF USE, CREOSOTE BUILDUP MAY OCC UR RAP IDLY. INS PE CT AND CLEAN VENTI NG
SYSTEM FREQUENTLY.
------- ----- ----- ----- ----- ----- ----- ----- ---- ------- ----- ----- ----- ----- ----- ----- ----- ---- ------- ----- ----- ----- ----- ----- --- ---
KEEP VIEWING, AS H REMOVAL AND HOPPER DOORS TIGHTLY CLOSED DUR I NG O PER ATION.
REPLACE GLASS WITH CERAMIC GLASS ONLY.
------- ----- ----- ----- ----- ----- ----- ----- ---- ------- ----- ----- ----- ----- ----- ----- ----- ---- ------- ----- ----- ----- ----- ----- -----
RATING: 120 VOLTS 2.0 AMPS 475 WATTS 60 HZ. ROUTE POWER SUPP LY CORD AWAY FROM UNIT.
------- ----- ----- ----- ----- ----- ----- ----- ---- ------- ----- ----- ----- ----- ----- ----- ----- ---- ------- ----- ----- ----- ----- ----- -----
LIGHTING/SHU TDOWN INSTRUCTIONS : PLACE SMALL AMOUNT OF PELLETS IN GRATE-PLACE PROPRIETORY FIRE
STAR TER ON P E LLET S - P RES S ON T OUCH PAD - LI GHT - CLOS E DO OR . SELECT FEED RATE AND FAN SPEED.
TO SHUT DOWN; PRESS OFF TOUCH PAD. REFER TO OPERATORS MANUAL, FOR ADDITIO NAL DE TAILS.
------- ----- ----- ----- ----- ----- ----- ----- ---- ------- ----- ----- ----- ----- ----- ----- ----- ---- ------- ----- ----- ----- ----- ----- ------
CAUTION: MOVING PARTS MAY CAUSE INJURY. DO NOT OPERATE WITH PANEL OPEN.
DANGER: RISK OF ELECTRIC SHOCK. DISCONNECT POWER BEFORE SERVICING UNIT.
WARNING: HOT PARTS DO NOT OPERATE WITH SIDE PANELS OPEN.
MANUFACTURED BY: DATE OF MFG. / DATE OF FABRICATION
DANSONS INC. EDMONTON, AB, CANADA
1-877-303-3134
TESTÉ PAR UL 1482-00, ASTM E 1509-04, ULC- 627-00, ULC-S628-M93,
POUR L' CU TILIS ATI ON DANS LES MAISONS MANUF ACTURÉ ES SELON DES RÈG LES ADMINISTRATIV E S DE L'C
ORÉGON 814-23-900 À 814-23-909
MINIMUM CLEARANCES TO COMBUSTIBLES / MINIMUM DE DÉGAGEMENTS JUSQU’A L A COMBUSTIBLE
A. 2 IN/PO, (50 MM) D. 16 IN/PO, (406.4 MM)
B. 6 IN/PO, (152.5 MM) E. 2 IN/PO, (50 MM )
C. 2 IN/PO, (50 MM) F. 48.5 IN/PO, (1250 MM )
BUILT IN INSTALLATION : (REQUIRES ACI-3H2 OR ACI-3VL BUILT IN KITS) SEE INSTALLATION MANUAL FOR DETAIL.
FR AMING OP ENIN G: CLEAR ANCES :
HEIGHT = 26 ” SIDE & R E AR S TAND-O FF S TO FR AMING = 0”
WIDT H = 38” HOP P E R TOP TO FRAMI NG = 1”
DEP TH = 24”
INSTALLEZ SELON ET UTILISEZ SEULEMENT L'CINSTALLATION DE MANUFACTURER.S ET LES C ONSIGNES
D'UT ILI S ATION. LES FONCTI ON NAI R ES LOCAUX ENTREZ EN CONTACT AVE C BÂ TIMENT O U FEU AU SUJ ET
DES R ESTR I CTIONS ET INS P E CTION D'CIN S TALLATION DANS VOTR E Z ONE.
________________________________________________________________________________________
AVERTIR N'INSTALLENT PAS L'CAPPAR EIL DANS UNE SALLE DE SOMMEIL. POUR L'CUSAGE ONLV AVEC 1/4.
(6 MM). 3/8. (10MM) CAR BUR ANT E N B OIS PE LLETISÉ. L' UTILISATI ON De L' AUTRE CARBURANT P E UT END
OMMAGER L'UNITÉ ET CAUSER UN ÉTAT DANGER E UX.
ENTRÉE ÉVALUANT 8,500 – 8,770 BTU/LB DE CARBURANT DE GRANULE.
_________________________________________________________________________________________
INSTALLEZ SUR UN PROTECTEUR DE PLANCHER DE NON-COMSUSTIBLE ÉTENDANT SOUS L'CAPPAREIL ET LES
6 DEDANS (152.4 MILLIMÈTRE) AU DELÀ DE L'CAVANT. N'O BS TRUEZ PAS L' CESPACE SOUS L'CUNITÉ. INSTALL EZ
ET U TILISEZ SEU LEME NT DANS UNE MAÇO NNERIE D'CACQU IESCEM EN T DE CODE OU UNE CHEMI NÉ E CONS TRUITE
PAR USINE ÉNUMÉR ÉE. NE RET IREZ PAS LES BRIQUES O U LE MOR TIER DE L'CUT ILIS ATION DE CHEMI NÉE DE
MAÇONNERIE UN PROTECTEUR NON-COMBUSTIBLE DE PLANCHER ÉTENDANT DESSOUS ET 6 POUCES À L 'CAVAN
T DE L'CUNITÉ.
NE RELIEZ PAS CETTE UNITÉ À UNE CONDUITE DE
CHEMINÉE DE CHEMINÉE SERVANT UN AUTRE APPAREIL
CIR CUIT DE MIS E À L'AIR LIBRE: UN CI R CUIT DE MISE À L'AIR LIB R E DE P L. DE TYPE DOIT ÊTR E UTI LISÉ. LES DÉGAGE-
MENTS AVEC L'CÉVENT DE PL SONT SELON LES I NST R UCTIONS DU CIRC UIT DE M ISE À L'AIR LIBR E MANUFAC TUR ER.S.
VOIR LE BÂTIMENT LOCAL CODER ET LES INSTR UCTIO NS D' CAP PAREIL ET D'CÉ V ENT MANUFACTUR ER. S POUR DE S
PRÉCAU T IONS REQUIS E S P OUR PASSER LE CIR CUIT DE MIS E À L'AIR LIB R E PAR UN MUR OU UN PLAFO ND
COMBUSTIBLE.
DANS CE RTAINES CONDI TIONS D'C UT IL ISATION, L' CH ABILLAGE DE CRÉOSOTE PEUT SE P RO DUIRE R API DEMENT.
EXAMINEZ ET NETTOYEZ LE CIRCUIT DE MISE À L'AIR LIBRE FRECUENTLY.
_________________________________________________________________________________________
ACTIONNEZ L'CUNITÉ SEULEMENT AVEC DES P ORTES ENTIÈREMENT FERMÉES REMPLACENT LE VERRE PAR LE
VERRE EN CÉRAMIQUE SEULEMENT. ESTIMATION: 120 VOLTS 2, 0 AMPÈRES 60 HERTZ . CORDE D'CALIMENATION
D'CÉ NE RGIE D' CILT INÉRAIRE LOIN À PARTIR D' CUNI TÉ. INSTRUCTIONS DE LI GHTING/SHUTD O WN: P LACEZ UN
PEU DE GRANULES S UR LA GR ILLE - P LAC EZ LE DÉMAR R EUR DU FEU DE PR OPRIETO RY SUR DES GRANULES –
METTENT LE COMMUTATEUR "CMARCHE/CARRÊT" EN MARCHE - LUMIÈRE - À LA PORTE ÉTROITE. TOURNEZ LE
COMMUTATEUR DE CARBUR ANT AU BAS. POUR S'ARRÊTER, COMMUTATEUR " CMARCHE/ CARRÊT " DE TOUR
POUR SE RAPPORTER HORS FONCTION AU MANUEL D'COPÉRATEURS, POUR LES DÉTAILS SUPPLÉMENTAIRES.
AVERTISSENT: LES PIÈCES MOBILES PEUVENT CAUSER DES DOMMAGES. NE
FONCTIONNEZ PAS AVEC LE PANNEAU OUVERT.
DANGER: RISQUE DE DÉCHARGE ÉLECTRIQUE. DÉBRANCHEZ LA PUISSANCE
AVANT UNITÉ D'CENTRETIEN.
AVERTISSEMENT: LES PIÈCES CHAUDES NE FONCTIONNENT PAS AVEC LE PANNEAU
OUVERT.
FABRIQUE PAR:
INDUSTRIES CANADIENNES DE CONFORT; EDMONTON, AB, CANADA
VAILLEZ À NE PAS ENLEVER NI À DISSIMULER CE COLLANT