Description
Hyprocentrifugalpumpsaredesignedforcreatingandboostingpressureinuidcircuits.Thepumpoperatesbytaking
inuidfromtheinletportafterwhichitisslungbytheimpellerandexpelledthroughtheoutletport.Constructionfeatures
include housings, impellers and seals which come in a variety of materials in order to be resistant to a range of chemicals.
Standardmodelsofcentrifugalpumpsrotateclockwise,whenlookingatthefront(Voluteend)ofthepump.
Intended Uses
Hyprocentrifugalpumpsareintendedforcreatingorboostingdynamicpressureinapproveduids.Hyprocentrifugal
pumps should never be used to pump liquids above 140°F (60°C), or below 34°F (1°C). For pumps equipped with
hydraulic motors, the pump should not be run if the hydraulic oil temperature exceeds 160°F (71°C). Any uses outside
ofthosespeciedinthismanualareconsideredmisusesandareprohibited.ContactHyprotechnicalservicewithany
questionsregardingspecicacceptableuses.
Purpose of Manual
This manual provides instructions and requirements that must be met when installing, using and maintaining the
product(s)identiedonthecover.
If the product is sold, the seller must pass this manual onto the new owner.
The following special attention notices are used to notify and advise the user of this product of procedures that may be
dangerous to the user or result in damage to the product.
ATTENTION
Attention is used to notify of installation, operation, or maintenance information that is important but not safety related.
Thissymbolisusedtodenotethepresenceofanelectricalhazardthatwillresultinpersonalinjury,deathorproperty
damage.
Thissymbolisusedtodenotethepresenceofahazardthatwillresultinpersonalinjury,deathorpropertydamage.
California Proposition 65 Warning --Thisproductandrelatedaccessoriescontainchemicalsknowntothe
State of California to cause cancer, birth defects or other reproductive harm.
Misuses
Pentair’s line of Hypro centrifugal pumps are designed to operate effectively within the speed, pressure, and
environmentalrangesspeciedinthismanual.Operatingapumpoutsideoftheserangeswillvoidthewarrantyandcould
causedamagetoproperty,seriouspersonalinjury,ordeath.Youmustobservethefollowingsafetyguidelines:
• DO NOT run the pump faster than the maximum recommended speed
• DO NOTrunthepumphigherthanthemaximumspeciedpressure.
• DO NOT run pumps when the liquid has exceeded the maximum or minimum temperature limit (See Intended Uses).
• DO NOT pump non-approved liquids (See Fluid pumping Applications).
• DO NOT use pumps in explosive environments.
• DO NOT pump water or other liquids intended for human consumption.
• DO NOT run the pump dry.
• DO NOTrunthepumphydraulicmotorhigherthanthespeciedRPM,pressureorow.
• DO NOT run the pump with a higher than recommended voltage.
• DO NOT use pumps in an explosive environment.
• DO NOTattachapipe,hoseorttingtothepumpthatisnotratedforthemaximumpressureofthepump(outlet)or
vacuum of the pump (inlet).
• DO NOT run the pump in reverse of its intended rotation.
• DO NOT operate a pump with a gasoline engine in an enclosed area.