  9. Pepperl+Fuchs KFD2-UFC-Ex1.D User manual

Pepperl+Fuchs KFD2-UFC-Ex1.D User manual

Instruction Manual
1. Marking
Frequency Converter with Trip Values
KFD2-UFC-Ex1.D
Frequency Converter with Direction and Synchronization Monitor
KFD2-UFT-Ex2.D
ATEX certificate: TÜV 99 ATEX 1471
ATEX marking:
1 II (1)G [Ex ia Ga] IIC
1 II (1)D [Ex ia Da] IIIC
1 I (M1) [Ex ia Ma] I
ATEX certificate: TÜV 02 ATEX 1885 X
ATEX marking: 1 II 3G Ex nA nC IIC T4 Gc
IECEx certificate:
IECEx TUN 04.0007
IECEx TSA 18.0007X
IECEx marking: [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I
Ex ec nC IIC T4 Gc
North America Certifcates: FM22CA0016X / Project ID: 3009603 (FM)
Class I, Division 2, Groups A-D, T4
Class I, Zone 2, AEx nC, Group IIC, T4
Class I, Zone 2, Ex nA nC, Group IIC, T4
Associated apparatus with intrinsically safe circuits for:
Class I, Division 1, Groups A-D; Class II, Division 1, Groups E-G;
Class III
Class I, Zone 0, [AEx ia] IIC, Class I, Zone 0, [Ex ia] IIC
North America Certifcates: E223772 (UL)
Pepperl+Fuchs Group
Lilienthalstraße 200, 68307 Mannheim, Germany
Internet: www.pepperl-fuchs.com
2. Target Group, Personnel
Responsibility for planning, assembly, commissioning, operation,
maintenance, and dismounting lies with the plant operator.
The personnel must be appropriately trained and qualified in order to carry
out mounting, installation, commissioning, operation, maintenance, and
dismounting of the device. The trained and qualified personnel must have
read and understood the instruction manual.
Prior to using the product make yourself familiar with it. Read the
instruction manual carefully.
3. Reference to Further Documentation
Observe laws, standards, and directives applicable to the intended use
and the operating location.
For mining applications, observe laws, standards, and directives
applicable to the operating location.
The corresponding datasheets, manuals, declarations of conformity, EU-
type examination certificates, certificates, and control drawings if
applicable supplement this document. You can find this information under
www.pepperl-fuchs.com.
For specific device information such as the year of construction,
scan the QR code on the device. As an alternative, enter the serial number
in the serial number search at www.pepperl-fuchs.com.
If you use the device in safety-related applications, observe the
requirements for functional safety. You can find these requirements in the
functional safety documentation under www.pepperl-fuchs.com.
4. Intended Use
The device is only approved for appropriate and intended use. Ignoring
these instructions will void any warranty and absolve the manufacturer
from any liability.
The device is used in control and instrumentation technology
(C&I technology) for the galvanic isolation of signals such as 20 mA and
10 V standard signals or alternatively for adapting or standardizing signals.
The device has intrinsically safe circuits that are used for operating
intrinsically safe field devices in hazardous areas.
Use the device only within the specified ambient and operating conditions.
Only use the device stationary.
The device is an associated apparatus according to IEC/EN 60079-11.
The device is an electrical apparatus for hazardous areas of Zone 2.
The device may be installed in the non-hazardous area.
If you use the device in safety-related applications, observe the
information for safety function and safe state.
Frequency Converter with Trip Values
The device changes a digital input signal into a proportional free
adjustable 0/4 mA to 20 mA analog output signal and functions as a switch
amplifier and a trip alarm.
Frequency Converter with Direction and Synchronization Monitor
The device analyzes 2 digital signals (NAMUR sensor/mechanical
contact) from a explosion-hazardous area and functions
as a rotation direction indicator, slip monitor, frequency monitor
or synchronization monitor.
5. Improper Use
Protection of the personnel and the plant is not ensured if the device is not
used according to its intended use.
If circuits with type of protection Ex i are operated with non-intrinsically
safe circuits, they must no longer be used as circuits with type of
protection Ex i.
6. Mounting and Installation
Do not mount a damaged or polluted device.
The device is designed for mounting on a 35 mm DIN mounting rail
according to EN 60715.
Mount the device in a way that the device is protected against mechanical
hazard. Mount the device in a surrounding enclosure for example.
Ensure that the surrounding enclosure can only be opened with a tool.
The device fulfills a degree of protection IP20 according to IEC/EN 60529.
The device must be installed and operated only in a controlled
environment that ensures a pollution degree 2 (or better) according to
IEC/EN 60664-1.
If used in areas with higher pollution degree, the device needs to be
protected accordingly.
Do not mount the device in the dust hazardous area.
The device must be installed and operated only in an environment of
overvoltage category II (or better) according to IEC/EN 60664-1.
Supply the device with a power supply that meets the requirements for
safety extra-low voltage (SELV) or protective extra-low voltage (PELV).
If you are using the Power Rail, supply the Power Rail only via the
corresponding power feed modules or power supplies. Do not supply the
Power Rail via isolators.
Observe the installation instructions according to IEC/EN 60079-14.
If you install the device in safety-related applications, observe the
requirements for functional safety.
Requirements for Cables and Connection Lines
Observe the permissible core cross section of the conductor.
When using stranded conductors, crimp wire end ferrules on the
conductor ends.
Use only copper conductors.
Use only one conductor per terminal.
When installing the conductors the insulation must reach up to the
terminal.
Observe the tightening torque of the terminal screws.
If the voltage is greater than 50 V AC or 120 V DC, switch off the voltage
before connecting or disconnecting the device.
Only use cables and connection lines with a temperature range
appropriate to the application.
Requirements for Usage as Associated Apparatus
If circuits with type of protection Ex i are operated with non-intrinsically
safe circuits, they must no longer be used as circuits with type of
protection Ex i.
Observe the respective peak values of the field device and the associated
apparatus with regard to explosion protection when connecting intrinsically
safe field devices with intrinsically safe circuits of associated apparatus
(verification of intrinsic safety). Also observe IEC/EN 60079-14 and
IEC/EN 60079-25.
Intrinsically safe circuits of associated apparatus can be led into
hazardous areas. Observe the compliance of the separation distances to
all non-intrinsically safe circuits according to IEC/EN 60079-14.
Observe the compliance of the separation distances between two
adjacent intrinsically safe circuits according to IEC/EN 60079-14.
Requirements for Equipment Protection Level Gc
The device must be installed and operated only in surrounding enclosures
that
lcomply with the requirements for surrounding enclosures according to
IEC/EN 60079-0,
lare rated with the degree of protection IP54 according to
IEC/EN 60529.
Connection or disconnection of energized non-intrinsically safe circuits is
only permitted in the absence of a potentially explosive atmosphere.
Provide a transient protection. Ensure that the peak value of the transient
protection does not exceed 140 % of the rated voltage.
DOCT-8421 / 2022-09 1 / 2
7. Operation, Maintenance, Repair
If you operate the device in safety-related applications, observe the
requirements for functional safety. In case of operating in low demand
mode, plan appropriate intervals for the proof test.
If the voltage is greater than 50 V AC or 120 V DC, switch off the voltage
before connecting or disconnecting the device.
Do not use a damaged or polluted device.
Do not repair, modify, or manipulate the device.
If there is a defect, always replace the device with an original device.
Requirements for Equipment Protection Level Gc
Connection or disconnection of energized non-intrinsically safe circuits is
only permitted in the absence of a potentially explosive atmosphere.
Only use operating elements in the absence of a potentially explosive
atmosphere.
Only use the programming socket in the absence of a potentially explosive
atmosphere.
8. Delivery, Transport, Disposal
Check the packaging and contents for damage.
Check if you have received every item and if the items received are the
ones you ordered.
Always store and transport the device in the original packaging.
Store the device in a clean and dry environment. The permitted ambient
conditions must be considered, see datasheet.
The device, built-in components, packaging, and any batteries contained
within must be disposed in compliance with the applicable laws and
guidelines of the respective country.
DOCT-8421 / 2022-09 2 / 2

This manual suits for next models

1

Other Pepperl+Fuchs Media Converter manuals

Pepperl+Fuchs AVS78E User manual

Pepperl+Fuchs

Pepperl+Fuchs AVS78E User manual

Pepperl+Fuchs ENA42HD-S J1939 Series Use and care manual

Pepperl+Fuchs

Pepperl+Fuchs ENA42HD-S J1939 Series Use and care manual

Pepperl+Fuchs KCD2-UT2-1 User manual

Pepperl+Fuchs

Pepperl+Fuchs KCD2-UT2-1 User manual

Pepperl+Fuchs PCV-USB-RS485 User manual

Pepperl+Fuchs

Pepperl+Fuchs PCV-USB-RS485 User manual

Pepperl+Fuchs ENI11HD User manual

Pepperl+Fuchs

Pepperl+Fuchs ENI11HD User manual

Pepperl+Fuchs KFU8-FSSP-1.D-Y User manual

Pepperl+Fuchs

Pepperl+Fuchs KFU8-FSSP-1.D-Y User manual

Pepperl+Fuchs KFD2-HLC-Ex1.D Series User manual

Pepperl+Fuchs

Pepperl+Fuchs KFD2-HLC-Ex1.D Series User manual

Pepperl+Fuchs HiC2081 User manual

Pepperl+Fuchs

Pepperl+Fuchs HiC2081 User manual

Pepperl+Fuchs ICA-AI-I/U-IO-V1 User manual

Pepperl+Fuchs

Pepperl+Fuchs ICA-AI-I/U-IO-V1 User manual

Pepperl+Fuchs PS1000-D2-24.10 Manual

Pepperl+Fuchs

Pepperl+Fuchs PS1000-D2-24.10 Manual

Pepperl+Fuchs ENI11HD User manual

Pepperl+Fuchs

Pepperl+Fuchs ENI11HD User manual

Pepperl+Fuchs KFD2-PT2-Ex1 User manual

Pepperl+Fuchs

Pepperl+Fuchs KFD2-PT2-Ex1 User manual

Pepperl+Fuchs CVS36M Series User manual

Pepperl+Fuchs

Pepperl+Fuchs CVS36M Series User manual

Pepperl+Fuchs WCS Series User manual

Pepperl+Fuchs

Pepperl+Fuchs WCS Series User manual

Pepperl+Fuchs ENI58PL-S Series User manual

Pepperl+Fuchs

Pepperl+Fuchs ENI58PL-S Series User manual

Pepperl+Fuchs KF GUT-(EX)1.D Series User manual

Pepperl+Fuchs

Pepperl+Fuchs KF GUT-(EX)1.D Series User manual

Pepperl+Fuchs KFD2-GUT-Ex1.D User manual

Pepperl+Fuchs

Pepperl+Fuchs KFD2-GUT-Ex1.D User manual

Pepperl+Fuchs ENA TL IO Series User manual

Pepperl+Fuchs

Pepperl+Fuchs ENA TL IO Series User manual

Pepperl+Fuchs WCS Series User manual

Pepperl+Fuchs

Pepperl+Fuchs WCS Series User manual

Pepperl+Fuchs HID2891 User manual

Pepperl+Fuchs

Pepperl+Fuchs HID2891 User manual

Pepperl+Fuchs KFD2-HLC-Ex1.D Series User manual

Pepperl+Fuchs

Pepperl+Fuchs KFD2-HLC-Ex1.D Series User manual

Pepperl+Fuchs KFD2-HLC-Ex1.D Series User manual

Pepperl+Fuchs

Pepperl+Fuchs KFD2-HLC-Ex1.D Series User manual

Pepperl+Fuchs KCD2-UT2-1 User manual

Pepperl+Fuchs

Pepperl+Fuchs KCD2-UT2-1 User manual

Pepperl+Fuchs KFD2-UT2 Series User manual

Pepperl+Fuchs

Pepperl+Fuchs KFD2-UT2 Series User manual

Popular Media Converter manuals by other brands

Westermo RS-232 installation manual

Westermo

Westermo RS-232 installation manual

LA Audio Digibox AES D2 user guide

LA Audio

LA Audio Digibox AES D2 user guide

DigitaLinx IPEX5001-D install guide

DigitaLinx

DigitaLinx IPEX5001-D install guide

Renishaw VIONiC REXM20 installation guide

Renishaw

Renishaw VIONiC REXM20 installation guide

Raisecom RC902-FE4E1-BL user manual

Raisecom

Raisecom RC902-FE4E1-BL user manual

Humandata LNX-203 user manual

Humandata

Humandata LNX-203 user manual

Atoll Electronique DAC200 owner's manual

Atoll Electronique

Atoll Electronique DAC200 owner's manual

April Music Stello DA220 MK2 owner's manual

April Music

April Music Stello DA220 MK2 owner's manual

Cosel RMC15A instruction manual

Cosel

Cosel RMC15A instruction manual

Omnitron Systems Technology FlexPoint 10FL/2 User instructions

Omnitron Systems Technology

Omnitron Systems Technology FlexPoint 10FL/2 User instructions

Transition Networks J/E-PSW-FX-02(SC) user guide

Transition Networks

Transition Networks J/E-PSW-FX-02(SC) user guide

Shinybow USA SB-6358 instruction manual

Shinybow USA

Shinybow USA SB-6358 instruction manual

Moxa Technologies IMC-21A IMC-21A Quick installation guide

Moxa Technologies

Moxa Technologies IMC-21A IMC-21A Quick installation guide

Global Cache GC-CXG quick start guide

Global Cache

Global Cache GC-CXG quick start guide

artisan VMIVME-3136A product manual

artisan

artisan VMIVME-3136A product manual

Texas Instruments THS1031 manual

Texas Instruments

Texas Instruments THS1031 manual

Lika Posicontrol IF55 LIN CB Series Mounting instructions

Lika

Lika Posicontrol IF55 LIN CB Series Mounting instructions

HQ Power HQM119C user manual

HQ Power

HQ Power HQM119C user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.