manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Perfect Prime
  6. •
  7. Thermal Camera
  8. •
  9. Perfect Prime IR0002 User manual

Perfect Prime IR0002 User manual

Thermal Imaging Camera Manual
°C
°C °C
±2% or ±2°C(±2% or ±4)
±40°C°C
°C ±50°C
1. Slide the battery cover open for inserting new
batteries into IR0002
2.Ensure polarity of batteries inserted are correct
3.Cloce the battery cover.
3-Menu’s
°C
°C
IR0002
1. Introduction
IR0002 is a thermal Imaging Camera combining
functions of surface temperature measurement
and real-time thermal imaging.
Normal Infrared thermometer measures each
temperature points one by one, this instrument
help reduce measurement time by identifying
potential problems through thermal image on
the color screen, users can quickly locate the
c e n t r a l p o i n t t o m e a s u r e c u r s o r a n d
temperature. This product is equipped with a
vision camera to improve recognition, it can turn
thermal i m a g e into visible ima g e base on
practical requirements.
Thermal image and visible image can be stored
in the memory card, captured images can be
stored in PC for report or for printing.
This product is most suitable for electrician;
maintenance personnel and house owners for
identifying potential problem areas.
T he f o l l o w i ng f u n c t i o n s h e l p t o i m pr o ve
accuracy and usability of this product:
● Adjustable radiation coefficient and reflection
background compensation, it helps to improve
accuracy of measuring semi-reflective surfaces.
● The marking of hot spot and cold spot can help
user to locate the hottest and coldest area of
thermal imaging temperature.
● Choice of different color palettes.
2. Safety Precautions
Pl e as e c are ful ly re a d thi s m an u al be for e
operation to ensure accurate measurements.
Please strictly follow this manual to operate this
product, in case of any problems due to
operational errors, maintenance charge may be
incurred.
Do not use this product under explosive; damp
or corrosive environment.
If the product is damaged, broken or has just
been repaired, the measurement results might
be inaccurate.
Please refer to radiation coefficient to get the
a c c u r a t e t e m p e r a t u r e m e a s u r e m e n t s .
Measured temperature might be lower than
a c t u a l te mp e r a tu re b e c a u s e of re fle c t i v e
s u r f a c e a nd th es e s u r fa ce s m i g h t c au se
potential burning hazard to users.
4.Structure
6.Menu Description
5. Battery Installation
Figure 2 Structure of Product
Start up the instrument and then put the head of
sensor close to the worktop. Press “up” key for 5
seconds to eliminate the noise.
Press “image capturing” key for 5 seconds to
turn on LED light to assist working of visible
camera if needed.
7. Focal distance
8. Elimination of noise
9. LED light
Press “Start-up” key for 5 seconds to power up
the instrument.
Press “menu” key for 1 second to enter mode
setting of basic functions.
The LCD shows 5 function setting options in 1
screen, press “up” or “down” key to scroll
through the menus and select the function for
adjustment by the yellow option box.
Press “select” key and select “menu” option and
edit the value. Press “up” or “down” key to edit
the value, . After adjustment, confirm the new
value and press “menu” key to exit the edit
mode.
10. Product Operation
0002 is of fixed-focal thermal Imaging Camera
design and applicable distance is 50cm (20min).
IR
3.Product Specifications
If “NO SD” displayed at the lower left corner of
screen, it indicates SD card is not installed.
If “FULL” is displayed at the lower left corner of
screen, it indicates that SD card is full.
1. Press “menu” key to enter into the mode of “menu”.
2. Select the image storage module using the arrow
keys.
3. Press the “SELECT“ button to select the picture you
want to view.
4. Press the arrow keys to view other pictures.
5. Press the SELECT button to view pictures.
6. Press the above key on the screen will display
"Delete photo yes no", then press the MENU key to
delete the picture, Press "SELECT" to cancel.
7.Press the MENU button to exit Review.
Every object have radiated infrared energy
and the amount of infrared energy depends on
t h e o b j e c t t e m p e r a t u r e a n d r a d i a t i o n
coefficient of their surface. IR0002 can sense
the infrared energy on the surface of object
and estimate the temperature based on the
sensed value of infrared energy. Many objects
(e.g. coated metal, wood, water, skin and
texture) can radiate energy, so it is easy to get
the acc urat e me a sure d va l ue. As t o th e
surface which is easy to radiate energy (high
radiation coefficient), the radiation coefficient
is greater than 90% (0.90).
This simple rule is not applicable to glossy
su rf a ce s o r co at e d me ta l b ec au s e th ei r
radiation coefficient is less than 60% (0.60).
These materials are not easy to radiate energy
s o t he y a r e c la s s i fie d a s l o w r ad i at i o n
coefficient materials.
To accurately measure the temperature of low
radiation coefficient materials, the radiation
coefficient can be adjusted for more accurate
estimation of actual temperature.
Emissivity can be adjusted from 0.10 to 1.00
with step size of 0.01, with default value at
0.95. Correct setting of emissivity is important
to the accurate measurement of temperature.
The surface emissivity has great impact on the
measured temperature of our product.
21. Emissivity of normal materials
Knowing the emissivity of measured surface
h e l p s t o g e t m o r e a c c u r a t e r e s u l t o f
temperature, the following table can be used as
a reference (This is for reference only and may
not apply in all cases)
22.Maintenance
Use wet cloth or liquid soap to clean the shell.
Do not use abrasive compound or isopropyl
alcohol or solvent to clean the shell or lens or
window.
“ C o l o r p a l e t t e ” m e n u c a n c h a n g e t h e
repres e n tation color of the infrared image
displayed on the screen or captured. A number
of color palettes are available with some color
palettes more applicable to some special areas.
Gray-scale color palette provides balanced
linear color, so it can help to fully reveal details.
High-contrast color palette can emphasize the
displayed color and is applicable to hot-cold
contrast situation. It is used to improve the color
c o n t r a s t o f h i g h - t e m p e r a t u r e a n d l o w -
temperature.
Iron red and rainbow color palettes provide a
mixed high-contrast gray-scale color palette.
The background temperature can be set between 0°C
and +36°C. Set the temperature compensation for
reflective background in the option of background.
Over-hot or over-cold object may influence the object
or th e s u r f a ce t em pe ra t u r e an d m ea su re me nt
accuracy of measured object. When the radiation
coefficient of the surface of the measured object is
low, th i s p h enom e non is obv i ous. Un d er many
sit uati o ns, ad j ust th e t empe r atu r e o f r eflec t ive
background to get the optimum measured result.
Turn on or off the marking of spot temperature. If
turning on, the marking of spot temperature indicates
that the hot spot or cold spot in the screen needs
additional appraisal. If turning off, it indicates that
user can focus on the measured pixel per time.
The product displays the temperature in unit of °C or
°F.
Under Time Setting menu, press “left” or “right”
key to select digit for adjust, press “up” or
“down” key to increase or decrease the time
value. After setting, press “menu” key to exit.
The measured temperature at the pixel center
is displaye d at the upper left corn e r an d
radiation coefficient is displayed at the upper
right corner respectively.
Move the product until hot spot or cold spot
coincides with the center of pixel. Direct the
product to the object whose temperature is
h i g h e r o r l o w e r t h a n t h e s u r r o u n d i n g
temperature to get the optimum measured
results.
11. Time setting
12. Measurement
13. Color palette
19. Check internal storage
18. Image Capture and Storage
17. Image mixing
16. Unit of temperature
15. Marking of spot temperature
14. Temperature of reflective background 20. Notes on Emissivity
0002 can store up to 25,000 images on the micro SD
card. Press image capturing button and the symbol of
“store photos yes no” will display on the screen. Press
“MENU” key to store image. Press “SELECT” key to
delete the captured image.
IR
0002 can capture visible image of infrared image to
accurately display the temperature distribution of
target area, and allow their mixing to make the
understanding of infrared image become easier.
To use this mixing function, press “left” or “right” key to
adjust the mixed image from 0% to 100%.
IR

Other manuals for IR0002

2

Other Perfect Prime Thermal Camera manuals

Perfect Prime IR0018 User manual

Perfect Prime

Perfect Prime IR0018 User manual

Perfect Prime IR203 User manual

Perfect Prime

Perfect Prime IR203 User manual

Perfect Prime IR0280 User manual

Perfect Prime

Perfect Prime IR0280 User manual

Perfect Prime IR0005 User manual

Perfect Prime

Perfect Prime IR0005 User manual

Perfect Prime IR0280H User manual

Perfect Prime

Perfect Prime IR0280H User manual

Perfect Prime IR202 User manual

Perfect Prime

Perfect Prime IR202 User manual

Perfect Prime IR0019 User manual

Perfect Prime

Perfect Prime IR0019 User manual

Perfect Prime IR0018 User manual

Perfect Prime

Perfect Prime IR0018 User manual

Perfect Prime IR0002 User manual

Perfect Prime

Perfect Prime IR0002 User manual

Perfect Prime IR281 User manual

Perfect Prime

Perfect Prime IR281 User manual

Perfect Prime IR0005 User manual

Perfect Prime

Perfect Prime IR0005 User manual

Popular Thermal Camera manuals by other brands

SEEK Reveal user manual

SEEK

SEEK Reveal user manual

AEMC Model 1950 quick start guide

AEMC

AEMC Model 1950 quick start guide

FLIR FLIR H Series Operator's manual

FLIR

FLIR FLIR H Series Operator's manual

IDEAL HeatSeeker 61-844EU instruction manual

IDEAL

IDEAL HeatSeeker 61-844EU instruction manual

FLIR FC-Series installation manual

FLIR

FLIR FC-Series installation manual

Sierra Olympic Viento-G quick start guide

Sierra Olympic

Sierra Olympic Viento-G quick start guide

Pard NV007V quick start guide

Pard

Pard NV007V quick start guide

FLIR Titanium DC019U-F user manual

FLIR

FLIR Titanium DC019U-F user manual

Argus Mi-TICS user manual

Argus

Argus Mi-TICS user manual

FLIR Extech i5 Getting started guide

FLIR

FLIR Extech i5 Getting started guide

Zeiss DTI 3/25 user manual

Zeiss

Zeiss DTI 3/25 user manual

Dali LT3 user manual

Dali

Dali LT3 user manual

InfiRay AT31 user manual

InfiRay

InfiRay AT31 user manual

HAZET-WERK 1992-2 operating instructions

HAZET-WERK

HAZET-WERK 1992-2 operating instructions

Raytheon Thermal-Eye 225D Specifications

Raytheon

Raytheon Thermal-Eye 225D Specifications

Hikmicro Gryphon GQ50L user manual

Hikmicro

Hikmicro Gryphon GQ50L user manual

Novus NVIP-2DPT-8731/30/T quick start guide

Novus

Novus NVIP-2DPT-8731/30/T quick start guide

Planck VISION SYSTEMS ThermaCheck TC160 Networking guide

Planck VISION SYSTEMS

Planck VISION SYSTEMS ThermaCheck TC160 Networking guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.