EnglishDeutsch
 logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Perlick
  6. •
  7. Accessories
  8. •
  9. Perlick Z2148 User manual

Perlick Z2148 User manual

This manual suits for next models

1

Other Perlick Accessories manuals

Perlick BBRN Series User manual

Perlick

Perlick BBRN Series User manual

Perlick Z2148EMU User manual

Perlick

Perlick Z2148EMU User manual

Perlick BC24 Series User manual

Perlick

Perlick BC24 Series User manual

Perlick Z2151 User manual

Perlick

Perlick Z2151 User manual

Perlick CS1DPSP User manual

Perlick

Perlick CS1DPSP User manual

Perlick BC Series User manual

Perlick

Perlick BC Series User manual

Popular Accessories manuals by other brands

Hillco 2810 Operator's manual

Hillco

Hillco 2810 Operator's manual

Siemens QSA2700D Basic documentation

Siemens

Siemens QSA2700D Basic documentation

Contours ZY024 manual

Contours

Contours ZY024 manual

Saivod VS621 manual

Saivod

Saivod VS621 manual

SCE ENVIRO-THERM SCE-TE170B24VSS user manual

SCE

SCE ENVIRO-THERM SCE-TE170B24VSS user manual

Z-Wave HSD-200Z user manual

Z-Wave

Z-Wave HSD-200Z user manual

turck FMX-IM-2UPLI63FX quick start guide

turck

turck FMX-IM-2UPLI63FX quick start guide

Decagon Devices 10HS manual

Decagon Devices

Decagon Devices 10HS manual

UPPAbaby Cup Holder user manual

UPPAbaby

UPPAbaby Cup Holder user manual

Elko SmartSensor Leakage Wireless manual

Elko

Elko SmartSensor Leakage Wireless manual

Grizzly H8371 instructions

Grizzly

Grizzly H8371 instructions

Panasonic HG-T Series user manual

Panasonic

Panasonic HG-T Series user manual

IFM Electronic Efector 250 Series Brief instructions

IFM Electronic

IFM Electronic Efector 250 Series Brief instructions

Virtuox VirtuCLEAN 2.0 user manual

Virtuox

Virtuox VirtuCLEAN 2.0 user manual

DigiDesign 888/24 I/O installation guide

DigiDesign

DigiDesign 888/24 I/O installation guide

PROZIS QUAY user manual

PROZIS

PROZIS QUAY user manual

patagonia PSI Vest user manual

patagonia

patagonia PSI Vest user manual

SFC Energy EFOY GO! manual

SFC Energy

SFC Energy EFOY GO! manual

https://manuals.online logo
https://manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2026 Manuals.Online. All Rights Reserved.

Problem: Beer flow is slower with Smart Coupler
than with standard Perlick coupler.
Probable Cause: Beer Flow Control Handle is in CLEAN position.
Solution: Slowly turn Beer Flow Control Handle to ON position.
Problem: Beer does not flow after keg is tapped.
Probable Cause: Smart Coupler has locked up.
Solution: First, turn Beer Flow Control Handle to OFF position then
turn Beer Flow Control Handle to CLEAN position. Wait
five seconds then turn Beer Flow Control Handle to
ON position.
Probable Cause: Beer Flow Control Handle is OFF.
Solution: Turn Beer Flow Control Handle to CLEAN position.
Wait five seconds then turn Beer Flow Control Handle to
ON position.
Probable Cause: Probe or Smart Coupler is dirty.
Solution: Clean Smart Coupler.
Probable Cause: Out of gas.
Solution: Reestablish gas flow.
Problem: Excessive foam.
Probable Cause: Beer temperature too high. Excessive beer flow rate. Beer
is over-carbonated
Solution: These problems are not caused by the Smart Coupler.
Follow established procedures to correct the problem.
* U.S. Patent #5,630,411
Form Z2148
04.06.04
8300 West Good Hope Road • Milwaukee, WI 53223 • Phone 414-353-7060
Fax 414-353-7069Toll Free 800-558-5592 • E-Mail: [email protected] • www.Perlick.com
OPERATING INSTRUCTIONS
SMART COUPLER with Empty Keg Sensor
The Smart Coupler* combines a
standard Perlick single-valve keg
coupler with a specially-designed
keg sensor that eliminates the
line loss that normally follows
every empty keg. Fresh kegs can
be drawn off immediately. The
beer lines are always full of beer.
•
Saves time
•
Reduces beer waste
•
Increases beer profits
•
Reduces aggravation
Part No.
■■26000F
No. 26000F
Smart Coupler with Empty Keg Sensor
Perlick’s Empty Keg Sensor
No. 40125
(Probe Washer Not Included)
IMPORTANT!
To ensure your complete satisfaction,
please read these instructions before using Perlick’s Smart Coupler.
Troubleshooting
Retrofitting Single Valve Couplers
Perlick single valve keg couplers can be
retrofitted to function as Smart Couplers.
Simply replace the probe with Perlick’s
No. 40125 empty keg sensor.
1. Remove probe washer from
bottom of probe.
2. Remove retaining screw and
yoke assembly.
3. Lift probe out of body.
4. Install Perlick’s empty keg sensor.
When replacing probe washer
make sure the surface marked
“up” faces the probe washer.
TAPPING and CLEANING PROCEDURES REPLACEMENT PARTS
Fig. 2
ON
Fig. 3
CLEAN
Fig. 1
OFF
45°
Filling the Lines the First Time
1. Turn Beer Flow Control Handle OFF.
(See Fig. 1).
2. Tap fresh keg.
3. Turn Beer Flow Control Handle to CLEAN.
(See Fig. 3).
4. Open the beer faucet. When solid beer
appears, close the faucet. The line is full.
5. Turn Beer Flow Control Handle ON.
(See
Fig.2)
. The line is full and ready for service.
When Tapping Fresh Kegs
1. Remove coupler from empty keg.
2. Turn Beer Flow Control Handle OFF.
(See Fig. 1).
2. Tap fresh keg in normal manner.
3. Turn Beer Flow Control Handle to CLEAN.
position.
(See Fig. 3).
Wait for five seconds
then turn to ON position.
(See Fig. 2).
To Restart System
If beer does not flow, first turn the Flow Control
Handle to OFF.
(See Fig. 1).
Then turn Handle to
the CLEAN position.
(See Fig. 3).
Wait for five
seconds then turn the Handle to ON position.
(See Fig. 2).
To Clean
1. Untap Keg in usual manner.
2. Turn Beer Flow Control Handle OFF
(See Fig. 1).
3. Attach cleaning adapter. Use Perlick’s
single cleaning adapter, No. 43657, if
cleaning from faucet to keg. If two or
more lines are cleaned, use Perlick’s
dual cleaning adapter, No. 43681.
4. Turn Beer Flow Control Handle to
CLEAN and clean as usual.
(See Fig. 3).
5. After flushing, turn Beer Flow Control
Handle OFF and retap keg.
(See Fig. 1).
6. To restore service, see above instructions.
Warranty
Perlick products are fully guaranteed against defects in both material and
workmanship for a period of one year from date of sale. Defective parts will be
replaced on a no-charge basis, F.O.B. our factory, subject to our inspection. We
are not responsible for parts damaged by alteration, unauthorized service,
accident or abuse.All costs incident to replacement to include freight, labor and/or
loss of sales are incidental to this warranty and must be borne by the user.
No. 43657 No. 43681
Single Adapter Dual Adapter
6
7
5
34
10
9
2
1
11
8
Item ........Part No. ....................Description
1. .......40125.....................Empty keg Sensor
2. .......43001A ..................Std. Yoke Assy.
3. .......2026.......................Hex Nut
4. .......2068-1....................Tailpiece
5. .......157R2P..................Washer
6. .......23682-2P...............Check Valve
7. .......31084-1..................Retaining Screw
8. .......31089-2P...............“O”Ring (3 per assy.)
9. .......43061.....................Body w/relief valve
10. .......31088-2P...............Bottom Seal Washer
11. .......31087-2P...............Probe Washer
Cleaning Adapters
Beer Flow Control
Handle Operating
Positions