Problem: Beer flow is slower with Smart Coupler
than with standard Perlick coupler.
Probable Cause: Beer Flow Control Handle is in CLEAN position.
Solution: Slowly turn Beer Flow Control Handle to ON position.
Problem: Beer does not flow after keg is tapped.
Probable Cause: Smart Coupler has locked up.
Solution: First, turn Beer Flow Control Handle to OFF position then
turn Beer Flow Control Handle to CLEAN position. Wait
five seconds then turn Beer Flow Control Handle to
ON position.
Probable Cause: Beer Flow Control Handle is OFF.
Solution: Turn Beer Flow Control Handle to CLEAN position.
Wait five seconds then turn Beer Flow Control Handle to
ON position.
Probable Cause: Probe or Smart Coupler is dirty.
Solution: Clean Smart Coupler.
Probable Cause: Out of gas.
Solution: Reestablish gas flow.
Problem: Excessive foam.
Probable Cause: Beer temperature too high. Excessive beer flow rate. Beer
is over-carbonated
Solution: These problems are not caused by the Smart Coupler.
Follow established procedures to correct the problem.
* U.S. Patent #5,630,411
Form Z2148
04.06.04
8300 West Good Hope Road • Milwaukee, WI 53223 • Phone 414-353-7060
Fax 414-353-7069Toll Free 800-558-5592 • E-Mail: [email protected] • www.Perlick.com
OPERATING INSTRUCTIONS
SMART COUPLER with Empty Keg Sensor
The Smart Coupler* combines a
standard Perlick single-valve keg
coupler with a specially-designed
keg sensor that eliminates the
line loss that normally follows
every empty keg. Fresh kegs can
be drawn off immediately. The
beer lines are always full of beer.
•
Saves time
•
Reduces beer waste
•
Increases beer profits
•
Reduces aggravation
Part No.
■■26000F
No. 26000F
Smart Coupler with Empty Keg Sensor
Perlick’s Empty Keg Sensor
No. 40125
(Probe Washer Not Included)
IMPORTANT!
To ensure your complete satisfaction,
please read these instructions before using Perlick’s Smart Coupler.
Troubleshooting
Retrofitting Single Valve Couplers
Perlick single valve keg couplers can be
retrofitted to function as Smart Couplers.
Simply replace the probe with Perlick’s
No. 40125 empty keg sensor.
1. Remove probe washer from
bottom of probe.
2. Remove retaining screw and
yoke assembly.
3. Lift probe out of body.
4. Install Perlick’s empty keg sensor.
When replacing probe washer
make sure the surface marked
“up” faces the probe washer.
TAPPING and CLEANING PROCEDURES REPLACEMENT PARTS
Fig. 2
ON
Fig. 3
CLEAN
Fig. 1
OFF
45°
Filling the Lines the First Time
1. Turn Beer Flow Control Handle OFF.
(See Fig. 1).
2. Tap fresh keg.
3. Turn Beer Flow Control Handle to CLEAN.
(See Fig. 3).
4. Open the beer faucet. When solid beer
appears, close the faucet. The line is full.
5. Turn Beer Flow Control Handle ON.
(See
Fig.2)
. The line is full and ready for service.
When Tapping Fresh Kegs
1. Remove coupler from empty keg.
2. Turn Beer Flow Control Handle OFF.
(See Fig. 1).
2. Tap fresh keg in normal manner.
3. Turn Beer Flow Control Handle to CLEAN.
position.
(See Fig. 3).
Wait for five seconds
then turn to ON position.
(See Fig. 2).
To Restart System
If beer does not flow, first turn the Flow Control
Handle to OFF.
(See Fig. 1).
Then turn Handle to
the CLEAN position.
(See Fig. 3).
Wait for five
seconds then turn the Handle to ON position.
(See Fig. 2).
To Clean
1. Untap Keg in usual manner.
2. Turn Beer Flow Control Handle OFF
(See Fig. 1).
3. Attach cleaning adapter. Use Perlick’s
single cleaning adapter, No. 43657, if
cleaning from faucet to keg. If two or
more lines are cleaned, use Perlick’s
dual cleaning adapter, No. 43681.
4. Turn Beer Flow Control Handle to
CLEAN and clean as usual.
(See Fig. 3).
5. After flushing, turn Beer Flow Control
Handle OFF and retap keg.
(See Fig. 1).
6. To restore service, see above instructions.
Warranty
Perlick products are fully guaranteed against defects in both material and
workmanship for a period of one year from date of sale. Defective parts will be
replaced on a no-charge basis, F.O.B. our factory, subject to our inspection. We
are not responsible for parts damaged by alteration, unauthorized service,
accident or abuse.All costs incident to replacement to include freight, labor and/or
loss of sales are incidental to this warranty and must be borne by the user.
No. 43657 No. 43681
Single Adapter Dual Adapter
6
7
5
34
10
9
2
1
11
8
Item ........Part No. ....................Description
1. .......40125.....................Empty keg Sensor
2. .......43001A ..................Std. Yoke Assy.
3. .......2026.......................Hex Nut
4. .......2068-1....................Tailpiece
5. .......157R2P..................Washer
6. .......23682-2P...............Check Valve
7. .......31084-1..................Retaining Screw
8. .......31089-2P...............“O”Ring (3 per assy.)
9. .......43061.....................Body w/relief valve
10. .......31088-2P...............Bottom Seal Washer
11. .......31087-2P...............Probe Washer
Cleaning Adapters
Beer Flow Control
Handle Operating
Positions

This manual suits for next models

1

Other Perlick Accessories manuals

Perlick BBRN Series User manual

Perlick

Perlick BBRN Series User manual

Perlick BC Series User manual

Perlick

Perlick BC Series User manual

Perlick Z2148EMU User manual

Perlick

Perlick Z2148EMU User manual

Perlick BC24 Series User manual

Perlick

Perlick BC24 Series User manual

Perlick CS1DPSP User manual

Perlick

Perlick CS1DPSP User manual

Perlick Z2151 User manual

Perlick

Perlick Z2151 User manual

Popular Accessories manuals by other brands

iNels RFTI-10B quick start guide

iNels

iNels RFTI-10B quick start guide

Reer MJBOX MJB1 quick start guide

Reer

Reer MJBOX MJB1 quick start guide

Midea COMPACT Series Service manual

Midea

Midea COMPACT Series Service manual

Pyronix CHIME Getting started

Pyronix

Pyronix CHIME Getting started

Gold Note B-7 Ceramic owner's manual

Gold Note

Gold Note B-7 Ceramic owner's manual

Lippert Components Solera user manual

Lippert Components

Lippert Components Solera user manual

Dometic CFX40 operating manual

Dometic

Dometic CFX40 operating manual

Sanitas SHD 80 Instructions for use

Sanitas

Sanitas SHD 80 Instructions for use

Stack TPMS Lite installation guide

Stack

Stack TPMS Lite installation guide

Tork Winch TW 2000 installation instructions

Tork Winch

Tork Winch TW 2000 installation instructions

OtterBox OBFTC-0038-A Safety instructions

OtterBox

OtterBox OBFTC-0038-A Safety instructions

Gram K3-F quick start guide

Gram

Gram K3-F quick start guide

Hydronix Hydro-Mix HT installation guide

Hydronix

Hydronix Hydro-Mix HT installation guide

Hally-Gally Piccolo 20.02.118 Assembly instructions

Hally-Gally

Hally-Gally Piccolo 20.02.118 Assembly instructions

AMX PCS2 datasheet

AMX

AMX PCS2 datasheet

Dorner 2100 Series Setup, operation & maintenance manual

Dorner

Dorner 2100 Series Setup, operation & maintenance manual

Basalte Sentido KNX Series installation manual

Basalte

Basalte Sentido KNX Series installation manual

DITEC PASM24W1 user guide

DITEC

DITEC PASM24W1 user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.