manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Perrin & Rowe
  6. •
  7. Dispenser
  8. •
  9. Perrin & Rowe Country 6695 Operation manual

Perrin & Rowe Country 6695 Operation manual

This manual suits for next models

11

Popular Dispenser manuals by other brands

BOWMAN CL003-0111 manual

BOWMAN

BOWMAN CL003-0111 manual

SIKA Power Cure operating instructions

SIKA

SIKA Power Cure operating instructions

Silver King Majestic SK12MAJ Technical manual and replacement parts list

Silver King

Silver King Majestic SK12MAJ Technical manual and replacement parts list

Franke F3Dn Twin Service manual

Franke

Franke F3Dn Twin Service manual

HURAKAN HKN-MT1 manual

HURAKAN

HURAKAN HKN-MT1 manual

STIEBEL ELTRON UltraHot Plus Operation and installation instructions

STIEBEL ELTRON

STIEBEL ELTRON UltraHot Plus Operation and installation instructions

Bobrick B-828 troubleshooting guide

Bobrick

Bobrick B-828 troubleshooting guide

DAN DRYER 282 installation guide

DAN DRYER

DAN DRYER 282 installation guide

Essity Tork 473208 manual

Essity

Essity Tork 473208 manual

CBS SD300BU-88 COMPONENT MAINTENANCE MANUAL WITH ILLUSTRATED PARTS LIST

CBS

CBS SD300BU-88 COMPONENT MAINTENANCE MANUAL WITH ILLUSTRATED PARTS LIST

Sealey MK77 manual

Sealey

Sealey MK77 manual

Fluid Management Accutinter 1600 End user guide

Fluid Management

Fluid Management Accutinter 1600 End user guide

Franke DVS SD99-010 Installation and operating instructions

Franke

Franke DVS SD99-010 Installation and operating instructions

Graco Dispensit 1053-10C operation & maintenance

Graco

Graco Dispensit 1053-10C operation & maintenance

DPR SED02 user manual

DPR

DPR SED02 user manual

ITALTINTO i50 user manual

ITALTINTO

ITALTINTO i50 user manual

Coca-Cola FREESTYLE 9000 user guide

Coca-Cola

Coca-Cola FREESTYLE 9000 user guide

Hewi 805.06.150 Mounting instructions

Hewi

Hewi 805.06.150 Mounting instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

The Soap Dispenser Collection
The Soap Dispenser Collection
Installation & User Guide
Perrin and Rowe is a registered trademark. 9006495 Issue 3
Replacement Pump Heads - Please specify colour
Perrin and Rowe products are manufactured in the UK, using the latest
technology and built to the highest quality standards.
We would like to thank you for purchasing a Perrin and Rowe product and
take this opportunity to invite you to look at other luxury products by us.
Please contact us to recieve our latest catalogue.
GUARANTEE & LIABILITY
Your Perrin & Rowe product has been manufactured to exacting standards. However, in the unlikely event that
you should experience any defect, the following guarantees will apply:
Your Perrin & Rowe product is guaranteed against any mechanical defect within five years of the date of
purchase. Should a fault occur; a free replacement part will be issued.
The surface finish of Perrin & Rowe products are guaranteed for one year from the date of purchase. This is
provided our care and maintenance instructions have been followed and that no scouring or aggressive cleaning
agents have been used.
This does not affect your statutory rights.
For full terms and conditions please contact your local distributor.
Should you require any advice, or
a quick solution to a problem with
this product please contact in the
first instance the
supplier/showroom from which it
was purchased.
Deck Mounted Wall Mounted
Free Standing
• Rubiq
6295 - Deck Mounted
• Orbiq
6395 - Deck Mounted • Deco
6195 - Deck Mounted
• Contemporary
6495 - Deck Mounted
6433 - Free Standing
6473 - Wall Mounted
• Traditional
6995 - Deck Mounted
6933 - Free Standing
6973 - Wall Mounted
• Country
6695 - Deck Mounted
6633 - Free Standing
6673 - Wall Mounted
2359.1/4" / mm
2359.1/4" / mm
70/mmmax.
2.3/4"
9.121040* 9.121036* 9.121041* 9.121039*
9.121037* 9.121038*
9.260649
Line up location holes & place 1.5mm
Key (supplied) inside to stop pump
rotating.
Hold pump head
& unscrew pump.
Reverse step to
install new pump.
500ML
250ML 250ML
29011.1/2" / mm
923.5/8" / mm
92
3.5/8"/mm
92
3.5/8"/mm
923.5/8" / mm
88
3.1/2"/mm
702.3/4" / mm
642.1/2" / mm
70
2.3/4"/mm
642.1/2" / mm
70
2.3/4"/mm
Replacement
Pump Assembly Pump Replacement
Method
Cut supplied tube to match current length•
70
2.3/4"/m
m
773" / mm
Congratulations on the purchase of your Perrin & Rowe Product. Correctly installed and with sensible care, this
product will give you many years of trouble free service.
The Soap Dispenser Collection
Installation & User Guide
IMPORTANT INFORMATION
If drilling into tiled walls, be careful to avoid the drill slipping and damaging the glazed surface.
Before you proceed... We recommend you engage the services of a registered plumber to install
this product.
In addition to the guide below it is essential that the written information overleaf is carefully read
and understood.
For ease of possible future servicing, we also recommend the soap pump assembly be flushed
clean every 6 to 7 months pumping warm water through it, preventing any future blockage.
CARE & MAINTENANCE
Wipe down after use to avoid water spotting and mineral build up. Due to metals in this product, if left for long
periods some soaps may discolour.
Occasional cleaning with warm soapy water, followed by a polish with a soft cloth is all that is required to keep
the plated finish in good condition.
Do not use proprietary abrasive liquids, powders, or pads to clean the dispenser. Do not use any
products with ammonia bleach or limescale remover. You will damage the plated finish and void your
guarantee.
BEFORE USE
• If further building work is to be carried out in the vicinity, cover the accessory to avoid damaging the finish.
2. Wall Mounted
1. Deck Mounted The diameter of the hole should be Ø30mm/1.1/8". The maximum
thickness of the surface must not exceed 70mm/2.3/4"
Before inserting the Dispenser Top & Shank ensure the Base part
is screwed onto the Shank section and surface area is clean and
dry.
Please note: The Base 'O' Ring Seal is an essential item and must
be fitted as indicated in diagram.
Once the Shank has been placed through the hole ensure the base
seal is immediately above the mounting surface.
Screw the Retaining Nut onto the Shank beneath the mounting
surface - hand tight is sufficient.
BASE
BASE 'O'
RING SEAL
MOUNTING
SURFACE
RETAINING
NUT
702.3/4"/ MM MAX
30O
1.1/8"
Remove security screw if fitted.
Pull dispenser pump head upwards and refill the container.
Push pump head back into position when filled.
Re-fit security screw if required.
•
•
•
•
500ml - Deck mounted
250ml - Wall and Free Standing
DO NOT OVER FILL
The same refill technique can be
used on the free standing and wall
mounted soap dispenser versions.
When positioning the soap
dispenser, note that the
clamping screw is
positioned at the base of
the rosette. Release
wallplate by unscrewing
clamping screw from the
base of the rosette. (See
hole template for correct
screw hole positions) CLAMPING
SCREW
DRIVE
SCREW
CENTRES
WALL
PLATE
ROSETTE
CENTRE
WALL
PLATE
CENTRE
2mm
Note that the centre line of the wallplate for these fittings is 2mm above the centre line of the accessory
rosette.
Before drilling holes, check centre positions using the accessory as a guide, clamping screw holes should
line up with marked positions.
Use No. 6 masonary drill for the supplied wall plugs. Only use supplied wall plugs where suitable.
When used for the first time it may be
necessary for you to prime the pump
with several downward movements.
The soap is dispensed by a single full
movement downwards.
SHANK
4. Service/Refill
5. OPERATION
Use 1.5mm Key supplied
(Retain key to remove pump)
Grub screw is
supplied but is
optional for
security/anti theft.