Philio PSC05 User manual

PSC05 Z-Wave Gateway
5Vdc power
Micro SD card slot
microSD
Add device Remove device
Reset
add remove
Assoc.

Getting Started
Power up the gateway
Power up the gateway to any 5V DC USB port and wait until red LED on.
And connect by using SSID in Wi-Fi connection of your mobile phone.
Default SSID : PSC05 : XX:XX:XX:XX:XX:XX
Default Password : 12345678
Install APP “Home Mate2”
Please download “ Home Mate 2 “ App from Google/App stores
Home Mate2
1.
2.
iOS Android

Find Gateway
Launch the " Home Mate 2” App, press the “ Local search “ button connecting to the
PSC05 WiFi gateway and retrieve the gateway’s UID. Or you can scan the QR code
directly to retrieve the gateway UID and then key in the default password “ 888888”.
3.
UID
Name
ID
Password
Login
Scan QR code from
Gateway rear side.
Local search
888888
Getting Started

Remark:
If the WiFi gateway couldn’t be found in your smartphone WiFi list, please use paper clip to press the “ reset” and hold the button until
red LED off (around 20 seconds). The gateway will reboot around 20 sec. later and red LED light keep steady on.
4. Gateway Connect To Internet
To connect the PSC05 gateway to your local WiFi router, please go to setting page
Setting page→Gateway Informaion→Wi-Fi network→STA mode→seclect the SSID of
the preferred router
Settings
Gateway Information
》
Gateway
Ver.
Gateway
Time
WiFi
network
Location
2.0
(GMT+08:00)Taipei
2.50314, 212.5842
Wi-Fi Mode
AP Mode
STA Mode
OFF
Choose SSID
iTaiwan01
iTaiwan02
iTaiwan03
Gateway Information→WiFi network2 STA mode3 select the SSID4
1 Setting page
Getting Started

AIEV8XLFH193IKLAOCUH PSC05
5. APP Connect to Gateway
Let your mobile phone connect to inernet and the select gateway that you wnat to
connect by long press icon of home mate2 as below.
Getting Started
UID
Name
Press Here connect to Gateway

Reset function
a. If you forget password or want to change to default status, you need process Reset.
b. If Gateway setting done and you would like carry Gateway to new place, press reset
button as below, Press 10s then release, Gateway will reset. Follow Getting Started step 1
again you will setting done in new place.
6.
Getting Started
reset
add remove

Setup Devices
1.
2.
3.
To add sensor devices or WiFi IP camera by pressing the “ + “ in “Devices” page
Select “ Include Device” → press “ ” ( the gateway LED will be flashing_START INCLUSION
as confirmation to proceed in inclusion mode)
To pull out the black Insulation Mylar from battery cover, the sensor will send signal to
gateway automatically and complete the inclusion.
Information
Include Device
Add Camera
CANCEL
Include
START INCLUSION
If you are not sure the device is in factory default, just run Exclusion.
If the device is door lock series, you must click security check box
below.
Devices
1 Devices page 2 Add devices
1 Select “Include Device” 2 Press ” ”START INCLUSION

If the sensor being included in other gateway before, please be sure to “ Exclusion”
the sensor firstly before you “ INCLUSION” it to the new gateway.
Here is the example to add 4 in 1 sensor to another gateway for reference.
For other sensors, please refer to below “Remark”.
4.
Method A:
In App Device page → Press “+” → Include Device → Press “Exclusion”1
Information
Include Device
Add Camera
CANCEL
Include
START INCLUSION
If you are not sure the device is in factory default, just run Exclusion.
If the device is door lock series, you must click security check box
below.
3 Select “Include Device” 4 Press ” ”Exclusion
Devices
1 Devices page 2 Add devices
Setup Devices

2 Once the gateway red LED blinking → Press tamper key three times within 1.5 seconds
→ App will show “ Device excluded” on App once completed exclusion →
And then press “ START INCLUSION” within 20 seconds
1 tamper key
Include
START INCLUSION
If you are not sure the device is in factory default, just run Exclusion.
If the device is door lock series, you must click security check box
below.
3 Press ” ”START INCLUSION
2 Device exclude
Setup Devices
Device exclude

Method B:
Press the “ remove “ button on the gateway1
Once the gateway red LED blinking → Press tamper key three times within 1.5 seconds
→ App will show “ device excluded” → Then press the “ add” button on the gateway
within 20 seconds, the gateway red LED will be blinking as confirmation to start
Exclusion process. (Once the sensor be added, the gateway red LED will be on.)
2 tamper key
3 Device exclude
4 add device
1 remove device
add remove
Setup Devices
Device exclude

Once completed inclusion:
You could appoint sensors in different rooms
by adding “+” new rooms.
This block right side as name and status, click right side to control device, click left side
to setup advance setting.
5.
add new rooms
Rooms
PIR
Triggered
sensor icon control decives
pir
Triggered
room
Room
Associate 》
Config 》
Event 》
device name
information 》
Setup Devices
device status
advance setting

Scenes
Press the “ + “ button to add the new Scenes, you may change the scenes icon/name
as you wish and select devices you would like to add.
Name change name
Change name
CANCEL OK
Name
Previous page Delete
change icon
add devices
curtain02 curtain03
curtain01light03
light01 light02

Macros
Press the “ + “ button to add the new Macros group, you may change the macros
icon/name as you wish and set up the scenario with If and Then or Option criteria.
Name
If Then option
change icon change name
Change name
CANCEL OK
Name
Previous page Delete
curtain02 curtain03
curtain01light03
light01 light02
add devices

In setting page you could retrieve App and the gateway detailed information by
clicking into each option.
Settings
User Information 》
App Information 》
Gateway Information 》
Other Settings 》
Background Settings 》
Option 》
If you would like to receive
the E-mail notification,
please fill in your E-mail
address/password in
columns shown below.
You may select different background from default or take new
photo as background by ourselves.
User Information
》
User
Email
Password
Commit

Advanced Function/Setting
Associate function:
The gateway is as console to communication/control sensor devices included.
However, the individual sensors could be associated to each other and communicate
directly without waiting further commands from Gateway to speed up the response
time. For example, you may the dimmer switch could be controlled by gateway side
and also smart button.
1.
Associate 》
+Device

Advanced Function/Setting
Re-configuration Function:
You can change the default setting according to your demand. For example, the sensitivity
default setting is 80. You may lower the sensitivity to 50 by key in below new figures.
2.
Notice:
All of the configuration, the data size is 1.
The configuration mark with star(*), means after the remove the setting still keep,
don't reset to factory default.Unless the user execute the “RESET” procedure.
The reserve bit or not supported bit is allowed any value, but no effect.
Config
》
Param
Value
Size
3
50
1
Read Write
PIR
Sensitivity
Default
80
Parameter
3
Value
0~99
PIR sensitivity settings.
0 means disable the PIR motion.
1 means the lowest sensitivity.
99 means the highest sensitivity
High sensitivity means can detected long
distance but if there is more noise signal
in the environment, it will re-trigger too
frequency.
Other manuals for PSC05
2
Table of contents
Other Philio Gateway manuals
Popular Gateway manuals by other brands

Comtrol
Comtrol DeviceMaster PNIO 2000 Series user guide

Duemmegi
Duemmegi Domino DFDALI manual

ZyXEL Communications
ZyXEL Communications ZyXEL ZyWALL USG-1000 quick start guide

Spectrum Controls
Spectrum Controls WebPort WP-R-3G-SW-0 quick start

LEAB
LEAB 1051009023 quick start guide

AAMP of America