Philio PAN44 User manual

Smart Energy Plug PAN44
This plug-in ON/OFF switch PAN44 is a devices displaying the Z- ave PlusTM logo can
also be used security enabled wireless switch, based on Z- ave PlusTM technology. Z-
ave PlusTM enabled with it regardless of the manufacturer, and can also be used in
other manufacturer’s Z- aveTM enabled networks. Remote On/Off control of the con-
nected load is possible with another manufacturer’s wireless Controller. Each switch is
designed to act as a repeater. Repeaters will re-transmit the RF signal to ensure that the
signal is received by its intended destination by routing the signal around obstacles and
radio dead spots. Because PAN44 supports Security Command Class, it can learn with
Secured controller. Its functionality and supported command classes are identical when
included as a secure and non-secure device.
This plug-in ON/OFF switch is able to detect instance wattage (1560 /UL/T /JP) and
overload current (14.5A with resistive load) of connected lights or appliances. hen de-
tecting overload state, the Switch will be disabled and it’s On/Off button will be lockout
of which LED will flash quickly. However, unplug and reconnect the switch will reset its
overload condition to normal status.
Specification
Operating Voltage 100V-240V~ 50Hz~60Hz
Maximum Load (Ampere) 13A (Resistive load) PAN44-1; PAN44-2
Range Minimum 40 m in door 100m outdoor line of sight
Operating Temperature 0°C ~ 40°C
Frequency Range 908.4MHz & 916.0MHz/ USA (PAN44-1);
920~927MHz/ Taiwan/ Japan (PAN44-2)
RF Maximum Power +10dBm (Peak), -10dBm (Average)
** Specifications are subject to change and improvement without notice.
Troubleshooting
Symptom Cause of Failure Recommendation
The Switch not working
and LED off
1.The Switch is not plugged into
the electrical outlet properly
2.The Switch break down
1. Check power connections
2. Don’t open up the Switch
and send it for repair.
The Switch LED illumi-
nating, but cannot control
the Switch of the load at-
tached
1.Check if the load plugged into
the Switch has its own ON/OFF
switch
2. The switch is protected
1. Set the ON/OFF switch of
the load attached to ON
2. Unprotected the switch or
follow the instruction of pro-
tection.
The Switch LED illumi-
nating, but the Detector
cannot control the Switch
1. Not carry out association
2. Same frequency interference
1. Carry out association
2. ait for a while to retry
LED keep flashing, but
cannot control Overload occurs
Remove the load attached or
check max. load cannot ex-
ceed 13A (Resistive load)

For Instruction to http://www.philio-tech.com
ANGER
anger of electrocution!
All works on the device may be performed only by a qualified and licensed elec-
trician. Observe national regulations.
Any works introducing changes into the configuration must be always per-
formed with disconnected voltage.
Choosing a Suitable Location
1. Do not locate the Module facing direct sunlight, humid or dusty place.
2. The suitable ambient temperature for the Module is 0°C~40°C.
3. Do not locate the Module where exists combustible substances or any
source of heat, e.g. fires, radiators, boiler etc.
4. After putting it into use, the body of Module will become a little bit hot of
which phenomenon is normal.
Adding to Z-WaveTM Network
In the front casing, there is an on/off button with LED indicator below which is used to
toggle switch on and off or carries out inclusion, exclusion, reset or association. hen
first power is applied, its LED flashes on and off alternately and repeatedly at 2 second
intervals. It implies that it has not been assigned a node ID and start SmartStart.
The table below lists an operation summary of basic Z- aveTM functions. Please refer to
the instructions for your Z- aveTM Certificated Primary Controller to access the Setup
function, and to include/exclude/reset devices
Warning:
1.Plug out to disconnect from power supply; o not plug in line.
2. o not exceed the max rating.
Function escription Annotation
No node ID The Z- ave™ Controller does not
allocate a node ID to the Switch.
LED 2-second on, 2-second
off
Add 1.Put your Z- ave™ controller into
1. inclusion mode by following the in-
structions provided by the controller
manufacturer.
2.Pressing On/Off button three times
within 2 seconds will enter inclusion
mode.

SmartStart 1.To initiate the SmartStart process,
please type in the first five digits of
DSK string or scan the QR code.
The QR Code can be found on
PAN44 or in the box. Ex:
DSK:18112-24021-58001-62259-
57092- 27453-08187-47408
2. PAN44 is supported with
SmartStart, it can be added to Z-
ave™ network by scanning the Z-
ave™ QR code on the product.
3. ithout further actions, PAN44
will be automatically included in a
certified Z- ave™ Controller with
SmartStart inclusion ability in 10
minutes after it turned on.
Remove 1.Put your Z- ave™ controller into
exclusion mode by following the in-
structions provided by the controller
manufacturer.
2.Pressing On/Off button three times
within 2 seconds will enter exclu-
sion mode.
3.Node ID has been excluded. LED 2s On, 2s Off (Enter
auto inclusion)
Reset 1.Pressing On/Off button
three times within 2 seconds
will enter inclusion mode.
Use this procedure only in
the event that the primary
controller is lost or other-
wise inoperable.
2. ithin 1 second, press On/Off but-
ton again for 5 seconds.
3.IDs are excluded. LED 2s On, 2s Off (Enter
auto inclusion)
Association 1.The PAN44 is an always listening
Z- ave™ device, so associations
may be added or removed by a con-
troller at any time. Or If your con-
troller requires to have the PAN44
send a 'node information frame or
NIF for associations, then pressing
the On/Off button three times within
2 seconds will cause the PAN44 to
send its NIF.
2.There is only one group for the
switch
Including a node ID allocated by Z- ave™ Controller means inclusion. Exclud-
ing a node
ID allocated by Z- ave™ Controller means exclusion.
Failed or success in including/excluding the node ID can be viewed from the Z-
ave™ Controller.
LE Indication
To distinguish what mode the switch is in, view from the LED for identification.
State Type LE Indication
Normal Under normal operation, toggle On/Off button between On and Off.
hen pressing On, LED lights up, whereas Off, LED is off.
No node ID Under normal operation, when the Switch has not been allocated a
node ID, the LED flashes on and off alternately at 2-second intervals.
By pressing On/Off button, it will stop flashing temporarily.

Learning hen PAN44 is in learning mode, LED flashes on and off alternately
and repeatedly at 0.5 second intervals.
Overload hen overload state occurs, the Switch is disabled of which LED
flashes on and off alternately at 0.2 second intervals. Overload state
can be cleared by unplugging and reconnecting the Switch to the wall
outlet.
Choosing a Suitable Location
1. Do not locate the Switch facing direct sunlight, humid or dusty place.
2. The suitable ambient temperature for the Switch is 0°C~40°C.
3. Do not locate the Switch where exists combustible substances or any source
of heat, e.g. fires, radiators, boiler etc.
4. After putting it into use, the body of Switch will become a little bit hot of
which phenomenon is normal.
Installation
1. Plug this On/Off Switch into a wall outlet near the load to be controlled.
2. Plug the load into the Switch. Make sure the load to be controlled cannot
exceed 13A.
3. Press the button or switch on the load to the ON position.
4. To manually turn ON the Switch, press and release the On/Off button. The
LED will turn ON, and the load plugged into the Switch will also turn ON.
5. To manually turn OFF the Switch, simply press and release the On/Off but-
ton. The LED will turn OFF and the load plugged into the Switch will also
turn OFF.
Programming
1. Basic Command Class / Binary Switch Command Class
The Switch will respond to BASIC and BINARY commands that are part of
the Z- ave™ system.
1-1 BASIC_GET / BINARY_S ITCH_GET
Upon receipt of the following commands from a Z- ave™ Controller, the
Switch will report its On/Off state to the node asked.
Basic Get Command: [Command Class Basic, Basic Get]
Basic Report Command:
Report OFF: [Command Class Basic, Basic Report, Value = 0(0x00)]
Report ON:[Command Class Basic, Basic Report, Value = 255(0xFF)]
Binary Switch Get Command:[Command Class Switch Binary, Switch
Binary Get]
Binary Switch Report Command:
Report OFF:[Command Class Switch Binary, Switch Binary Report,
Value =0(0x00)]
Report ON:[Command Class Switch Binary, Switch Binary Report,
Value = 255(0xFF)]
1-2 BASIC_SET / S ITCH_BINARY_SET
Upon receipt of the following commands from a Z- ave™ Controller, the
load attached to the Switch will turn on or off.
[Command Class Basic, Basic Set, Value = 1~99,255(0xFF)]: the load
attached to the Switch turns on.
[Command Class Basic, Basic Set, Value = 0(0x00)]: the load attached
to the Switch turns off.
[Command Class Switch Binary, Switch Binary Set, Value = 1~99,
(255)0xFF]: the load attached to the Switch turns on.
[Command Class Switch Binary, Switch Binary Set, Value = 0(0x00)]:
the load attached to the Switch turns off.

2. Z-Wave™’s Groups (Association Command Class Version 2)
The Switch can be set to send reports to associated Z- ave™ devices. It sup-
ports one association group with one node support for Lifeline Group.
For Lifeline Group, the Switch will report its latest status to Z- ave™ Con-
troller. Lifeline Group includes, S ITCH_BINARY_REPORT, METER_RE-
PORT, ALARM_REPORT.
2-1 Auto report to Lifeline Group (Maximum Node 5)
2-1-1 On/Off Event Report
hen “on” or “off” state has been changed, it will send Binary Switch Report
to the node of Lifeline Group.
Binary Switch Report
ON: [Command Class Switch Binary, Switch Binary Report, Value
=255(0xFF)]
OFF: [Command Class Switch Binary, Switch Binary Report, Value
=0(0x00)]
2-1-2 Instant Power Consumption vary over 5% report
hen the power consumption of load varies over 5%, it will send Meter report
to the nodes of Lifeline Group.
Meter Report Command:
[Command Class Meter ,Meter Report ,Rate Type = 0x01 ,Meter
Type = 0x01,Precision = 1,Scale = 0x02,Size = 4,Meter Value(W) ]
2-1-3 Overload alarm report
hen PAN44 detects the current is more than 14.5A, it will send Alarm Report
to Lifeline Group node.
The content of Alarm Report
Alarm report command:
[Command_Class_Alarm, Alarm_Report, Alarm Type = 0x08, Alarm
Level = 0xFF]
2-2 Response to Meter Get Command
The Switch will report its (1) instant Power Consumption ( att) or (2) accumu-
lated power consumption (K H) or (3) AC load Voltage (V) or (4) AC load
current (I) (5) load power factor (PF) to Z- ave™ Controller after receive the
Meter Get Command from Z- ave™ Controller.
2-2-1 Instant Power Consumption ( att) of Switch
hen receiving Meter Get Command, it will report Meter Report Command to
the node.
Meter Get Command: [Command Class Meter, Meter Get, Scale
=0x02(W)]
Meter Report Command:
[Command Class Meter,Meter Report,Rate Type = 0x01,Meter
Type =
0x01,Precision = 1,Scale = 0x02,Size = 4,Meter Value(W) ]
Example:
Meter Value 1 = 0x00 ( )
Meter Value 2 = 0x00 ( )
Meter Value 3 = 0x03 ( )
Meter Value 4 = 0xEA ( )
Meter( ) = Meter Value 3 *256 + Meter Value 4 = 100.2
2-2-2 Accumulated Power Consumption (K h)
hen receiving Meter Get Command, it will report Meter Report Command to
the node.
Meter Get Command:
[Command Class Meter, Meter Get, Scale = 0x00 KWh)]
Meter Report Command:
[Command Class Meter,Meter Report,Rate Type = 0x01 ,Meter
Type = 0x01,

Precision = 2,Scale = 0x00,Size = 4,Meter Value (KWh)]
Example:
Scale = 0x00 (K h)
Precision = 2
Size = 4 Bytes (K h)
Meter Value 1 = 0x00(K h)
Meter Value 2 = 0x01(K h)
Meter Value 3 = 0x38(K h)
Meter Value 4 = 0xA3(K h)
Accumulated power consumption (K h) = (Meter Value 2*65536) + (Meter
Value 3*256) + (Meter Value 4) = 800.35 (Kwh)
2-2-3 Clearing accumulated power consumption
henever re-start counting the accumulated power consumption is needed, you
can use Meter Reset Command to clear it.
Meter Reset Command: [Command Class Meter, Meter Reset]
2-2-4 AC load Voltage (V)
hen receiving Meter Get Command, it will report Meter Report Command to
the node.
Meter Get Command: [Command Class Meter, Meter Get, Scale
=0x04(V)]
Meter Report Command:
[Command Class Meter,Meter Report,Rate Type = 0x01,Meter
Type = 0x01 ,Precision = 1 ,Scale = 0x04 ,Size = 2 ,Meter
Value(V)]
Example:
Scale = 0x04 (V)
Precision = 1
Size = 2 (2 Bytes of V)
Meter Value 1 = 0x09(V)
Meter Value 2 = 0x01(V)
AC load Voltage = (Meter Value 1*256) +(Meter Value 2)= 230.5 (V)
2-2-5 AC load current ( I )
hen receiving Meter Get Command, it will report Meter Report Command to
the node.
Meter Get Command:
[Command Class Meter, Meter Get, Scale =0x05(I)]
Meter Report Command:
[Command Class Meter,Meter Report,Rate Type = 0x01,Meter Type
= 0x01,Precision = 2,Scale = 0x05,Size = 2,Meter Value(I)]
Example:
Scale = 0x05 (I)
Precision = 2
Size = 2 (2 Bytes of I)
Meter Value 1 = 0x01(I)
Meter Value 2 = 0x21(I)
AC load current = (Meter Value 1*256) +(Meter Value 2)= 2.89 (A)
2-2-6 load power factor (PF)
hen receiving Meter Get Command, it will report Meter Report Command to
the node.
Meter Get Command: [Command Class Meter, Meter Get, Scale
=0x06(PF)]
Meter Report Command:
[Command Class Meter ,Meter Report ,Rate Type = 0x01 ,Meter
Type = 0x01 ,Precision = 2 ,Scale = 0x06,Size = 1 Bytes ,Meter
Value(PF)]
Example:

Scale = 0x06 (PF)
Precision = 2
Size = 1 (1 Byte of PF)
Meter Value 1 = 0x63(PF) (It means that the load power factor is 0.99)
3. Z-Wave™’s Configuration
Configuration
Parameter Function Size
(Byte) Value Unit efault escription
1att Meter
Report Period 2
0x0000
-
0x7FFF
5s 720
0: Disable att
Report
1~32767: 5s~ 45h
2K H Meter
Report Period 2
0x0000
-
0x7FFF
10min 6
0: Disable K h
Report
1~32767:
10min~ 227days
3
Threshold of
current for Load
caution
2 10-1300 0.01A 1300 1300*0.01A
= 13A
4
Threshold of
K h for Load
caution
2 1-10000 1K h 10000 10000*1K h
= 10000 K h
5Restore switch
state mode 1 0-2 1
0: Switch off
1: Last switch state
2: Switch on
6Mode of Switch
Off function 1 0-1 1 0: Disable
1: Enable
7LED indication
mode 1 1-3 1
1: Show switch state
2: Show night mode
3: One flash mode
8 att differential 1 0-4 1 0 : Disable
mode
1 : 5%
2: 10%
3: 15%
4: 20%
9Switch status
report mode 1 0-1 1 0: Disable
1:Enable
3-1 att Meter Report Period:
If the setting is configured for 1hour (set value =720), PAN44 will report its
instant power consumption to Lifeline Group node every 1 hour. The maxi-
mum interval to report its instant power consumption is 45 hours
(5s*32767/3600=45hr). hen the setting is 0, PAN44 will disable att auto
report function. The default value is 720.
3-2 K H Meter Report Period:
If the setting is configured for 1 hour (set value =6), PAN44 will report its Ac-
cumulated Power Consumption (K h) to Lifeline Group node every 1 hour.
The maximum interval to report its Accumulated Power Consumption (K h)
is 227.55 days (10min*32767/1440=227.55 days). hen the setting is 0,
PAN44 will disable K H auto report function. The default value is 6.
3-3 Threshold of current for Load Caution
This is a warning when the current of load over the preset threshold value, if
the setting value is 1300, when the load current of Relay1 over this value,
PAN44 will send current meter report to warn the Lifeline Group node, the
range of the setting value is from 10 to 1300, and the default value is 1300.
3-4 Threshold of K h for Load Caution
This is a warning when the K h of load over the preset threshold value, If the
setting value is 10000, when the Accumulated Power Consumption of Relay1
over this value, PAN44 will send K H meter report to warn the Lifeline
Group node, minimum value is 1K h and default value is 10000 k h.
3-5 Restore switch state mode:

henever the AC power return from lost, PAN44 will restore the switch state
which could be S ITCH OFF、LAST S ITCH STATE、S ITCH ON. The
default setting is LAST S ITCH STATE.
3-6 Mode of switch off function:
The default setting is enable mode. hen manual On/Off function is disabled,
the RF command and include button can only switch On but not Off. This is
useful function for keeping the device in switch on state.
3-7 LED indication mode: The default setting is Show Switch State.
3-7-1 Show Switch State:hen switch is on, LED is on. hen switch is off,
LED is off.
3-7-2 Show Night mode:hen switch is on, LED is off. hen switch is off,
LED is on.
3-7-3 One Flash mode :hen the state of switch changes, LED will be on
only one second, then LED keeps off.
3-8 att differential mode:The default setting is 1 (= 5%).
henever att value of PAN44 changes over 5% of last reading value, it will
send Meter report to the Lifeline Group nodes. However, if att differential
mode as 0, the unsolicited report will be disabled.
3-9 Switch status report mode: The default setting is 1(Enable)
henever PAN44 manually switch on or off, it will send BINARY_S ITCH_
REPORT to the node of Lifeline Group.
Firmware update over the air (OTA)
PAN44 is based on 700 series SoC and supports Firmware Update Command
Class, it can receive the updated firmware image sent by controller via the Z-
ave™ RF media. It is a helpful and convenient way to improve some function
if needed.
The Switch supports Command Classes including
Command Class Version Required Security Class
Z- ave Plus Info 2 None
Security 0 1 None
Security 2 1 None
Supervision 1 None
Transport Service 2 None
Association 2 Highest granted Security Class
Association Group
Information 3Highest granted Security Class
Basic 2 Highest granted Security Class
Binary Switch 2 Highest granted Security Class
Configuration 4 Highest granted Security Class
Device Reset Locally 1 Highest granted Security Class
Firmware Update Meta Data 5 Highest granted Security Class
Indicator 3 Highest granted Security Class
Manufacturer Specific 2 Highest granted Security Class
Meter 5 Highest granted Security Class
Multi Channel Association 3 Highest granted Security Class
Notification 8 Highest granted Security Class
Powerlevel 1 Highest granted Security Class
Version 3 Highest granted Security Class

Note: Please make sure that the intensity of the plug of the electrical device must
be 16A and have same head as the enclosed plug before inserting to the socket.
isposal
This marking indicates that this product should not be disposed
with other household wastes throughout the EU. To prevent possi-
ble harm to the environment or human health from uncontrolled
waste disposal, recycle it responsibly to promote the sustainable
reuse of material resources. To return your used device, please use
the return and collection systems or contact the retailer where the
product was purchased. They can take this product for environ-
mental safe recycling.
Company of License Holder:Philio Technology Corporation
Address of License Holder:8F., No.653-2, Zhongzheng Rd., Xinzhuang Dist.,
New Taipei City 24257, Taiwan(R.O.C)
www.philio-tech.com
FCC Interference Statement
This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful inter-
ference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause harmful inter-
ference to radio communications.
However, there is no guarantee that interference will not occur in a particular in-
stallation.
If this equipment does cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and on, the user is encour-
aged to try to correct the interference by one of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which
the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
This device complies with Part 15 of the FCC Rules. Operation is subject to the follow-
ing two conditions:
(1)This device may not cause harmful interference.
(2)This device must accept any interference received, including interference that may
cause undesired operation.