Specplus SPS2GFSVA332
Page 2 of 2 2' x 4' Recessed Fluorescent, Lens Frame Troffer
Static, 3 Lamp T8 or T5
Ordering Information
Explanation of Catalog Number. Example: SPS2GFSVA332UNVH3
Options/Accessories
Special Lenses: Substitute VY for VA (standard) = .125" nominal pattern 12 with 7.8 oz. average weight
per square foot. Substitute VI for VA (standard) = .125" nominal pattern 12 with 6.8 oz. average weight per
square foot. Substitute S1 or S2 for VA (standard) =
Sky Acrylic Lens (see Sky Lens sell sheet for
further details).
Plaster Frame: Catalog Number: PF24.
Continuous Row Installation: For F type fixtures, half width flanges are required between
fixtures. Order Catalog Number: 2FC TRIM CSP (each joint).
Radio Interference Filter:
To order one RIF per fixture; SUFFIX: R.
To order one RIF per ballast; SUFFIX: B.
Fusing: Internal fast-blow fusing. SUFFIX A.
Internal slow-blow fusing. SUFFIX C.
Electrical Wiring Options: Consult factory.
Drywall Kit: Order Catalog Number: FK92X4. (Request Folio OA30-10 Rev. A).
Chicago Plenum: SUFFIX: C.
Specifications
Performance: In an installation of 3 lamp 32W luminaires in a room cavity ratio of 1, reflectance
80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .84. To prevent glare the VCP shall
be not less than 50 either lengthwise or crosswise (at 100fc level) and the average brightness at 65°
shall not exceed 2299 candelas per square meter. To control veiling reflections, luminaire output in
the 30°-90° zone shall not be less than 68.8%.
Specifications (continued)
Materials:Chassis parts are die-formed code gauge cold rolled steel. Housing
with side rails hemmed
over and housing ends turned-in for safe handling.
Finish:Chassis exterior–black baked polyester enamel. Cavity–white baked polyester enamel
minimum 86% reflectance. Phosphate undercoating.
Lenses:VA (standard) extruded virgin acrylic, 3/16" square based female cones, running 45° to the
panel edge, .095" nominal thickness (similar to pattern 12). VY (optional) .125" nominal pattern 12
with 7.8 oz. average weight per square foot. VI (optional) .125" nominal pattern 12 with 6.8 oz. aver-
age weight per square foot.
Electrical: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of
ballast, use wire suitable for at least 90°.
Labels: I.B.E.W. UL and ULc Listed.
This product may have a mercury containing lamp.
Manage in accord with Disposal Laws. See: www.lamprecycle.org
Specplus:
Recessed
fluorescent
troffer
S
Static
2
Fixture
Width
Lens Frame:
FS = Flat steel
frame.
RA= Regressed
aluminum
frame.
FA = Flat aluminum
frame.
Lens Shielding
Type:
VA=Virgin acrylic
(standard)
S1=Sky lens 1
S2=Sky lens 2
See options and
consult factory
3
Lamp
Quantity
Options:
Add appropriate suffix
to catalog no., ie: (A)
Ballast Type:
<20THD <10THD
1 & 2 Lamp Elec. T8 SO * HI*
1-3 Lamp Elec. T8 O3 * H3 *
1 & 2 Lamp 28W Elec. T5 –PI
1 & 2 Lamp 28W/54W Elec. T5 –PG
1-3 Lamp 54W Elec. T5 –P5
LOL T8 Dimming PS –
Other dimming options. Consult factory.
*Instant Start Standard
Instant Start (120, 277 or UNV)
Program Rapid Start (UNV only)
NOTE:
For T8 UNV, you must use H
I
,H3 Ballast Code.
Voltage:
120, 277 or
UNV=120-277
Lamp Type/
Fixture Length:
32=32W T8
28=28W T5
54=54W T5
(Nominal 48")
SP Standard Specplus Plus
SX For NYC Code – Local 3 Manufactured
0.0 45.0 90.0 FLUX
0 2694 2694 2694
5 2683 2687 2692 256
15 2592 2627 2658 742
25 2391 2479 2549 1141
35 2059 2194 2292 1365
45 1609 1733 1814 1323
55 1034 1120 1217 1004
65 571 570 631 587
75 317 260 294 309
85 126 108 98 121
90 000
Model No. SPS2GFSVA33212003
LER = FP - 70.6 IW - 84.4 BF - 0.87
Comparative yearly lighting energy cost per
1000 lumens = 3.40
Report Number: ITL49785
Catalog Number: SPS2GFSVA33212003
Lamps: (3) F32T8
Luminaire: 2' x 4' SpecPlus with regressed
aluminum door frame and extruded
virgin acrylic shielding .095" nominal
thickness (similar to pattern 12).
Ballast: M3-RN-T8-1LL-120
Report is based on 2850 Lumens per lamp.
Efficiency: 80.1%
CIE Type-Direct-Indirect
Plane: 0-Deg 90-Deg
Spacing Criteria: 1.2 1.3
Shielding Angles: 90 90
Plane: 0-Deg 90-Deg
Luminous Length: 46.000 21.875
CANDELA DISTRIBUTION
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. 0-DEG. 45-DEG. 90-DEG.
45 3504. 3774. 3950.
55 2776. 3007. 3267.
65 2080. 2077. 2299.
75 1886. 1547. 1749.
85 2226. 1908. 1731.
LUMINANCE DATA IN CANDELA/SQ. METER
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE
FLOOR CAVITY REFLECTANCE 0.20
RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
01 88 84 81 79 77 75 76 74 72
02 81 74 69 70 66 63 67 64 61
03 74 66 60 62 58 54 60 56 53
04 68 59 52 56 50 46 54 49 46
05 63 53 46 50 45 40 49 44 40
06 58 48 41 46 40 36 44 39 35
07 54 44 37 42 36 32 41 35 31
08 50 40 33 38 33 28 37 32 28
09 47 37 30 35 30 26 34 29 26
10 44 34 28 33 27 23 32 27 23
ZONE LUMENS % LAMP % FIXT
00-030 2139 25.0 31.2
00-040 3504 41.0 51.2
00-060 5832 68.2 85.2
00-090 6848 80.1 100.0
90-180 0000 0.0 000.0
00-180 6848 80.1 100.0
ZONAL LUMEN SUMMARY
Job Information Type:
For Factory Technical Information: (978) 657-7600 • Fax (978) 658-0595 02/10
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © Philips Group Section 1A/Folio E60-32 Rev. B
Ceiling Type:
G= Grid
(lay-in T bar)
F= Flanged (over
lap) Z spline and
plaster frame
Photometry Sky Lens Options
S1
S2