1 - INTRODUCTION
PREFACE
All rights reserved. No part of this publication may be reproduced, distributed, translated into other languages, or transmitted
by any electronic or mechanical media, including photocopying, recording, or any other storage and retrieval system, for any
purpose other than the purchaser's exclusively personal use, without the express written consent of the Manufacturer.
The Manufacturer is in no way responsible for the consequences of any operations performed in a manner different from what
is stated in the manual.
GENERAL CONSIDERATIONS
All operating instructions and recommendations described in this manual must be followed to:
• get the best possible performance from the equipment;
• keep the equipment in efcient condition.
Of particular importance is the training of personnel responsible for:
• the use and maintenance of the equipment in the correct way;
• the application of the indicated safety directions and procedures.
The images in this document are indicative of the product type and may differ in the details.
Revision: A
COPYRIGHT 2023
© PIETRO FIORENTINI S.P.A.
Operation, maintenance and warning manual

4
SSM-ICON 250
EN Operation, maintenance and warning manual
STATIC SMART METER |INTRODUCTION | REV . A

5
SSM-ICON 250
Operation, maintenance and warning manual
STATIC SMART METER |INTRODUCTION | REV . AEN
1.1 - REVISION HISTORY
Revision
index Date Review Contents
A05/2023 First issue
Tab. 1.1.

6
SSM-ICON 250
EN Operation, maintenance and warning manual
STATIC SMART METER |INTRODUCTION | REV . A
INDICE
1 - INTRODUCTION .................................................................................................................. 3
1.1 - REVISION HISTORY.................................................................................................................................. 5
2 - GENERAL INFORMATION ................................................................................................ 11
2.1 - MANUFACTURER IDENTIFICATION........................................................................................................ 11
2.2 - PRODUCT IDENTIFICATION ................................................................................................................... 11
2.3 - REGULATORY FRAMEWORK................................................................................................................. 12
2.4 - WARRANTY............................................................................................................................................ 12
2.4.1 - REFERENCE OPERATING CONDITIONS ..............................................................................................13
2.5 - RECIPIENTS, SUPPLY AND CONSERVATION OF THE MANUAL............................................................ 14
2.6 - LANGUAGE ............................................................................................................................................ 14
2.7 - SYMBOLS USED IN THE MANUAL......................................................................................................... 15
2.8 - IDENTIFICATION PLATES APPLIED ........................................................................................................ 16
2.8.1 - DEVICE IDENTIFIER ..............................................................................................................................17
2.8.2 - DESCRIPTION OF IDENTIFICATION PLATES ........................................................................................18
2.9 - MEASUREMENT UNIT GLOSSARY ........................................................................................................ 19
2.10 -QUALIFIED PROFESSIONALS ................................................................................................................ 19
3 - SAFETY .............................................................................................................................. 21
3.1 - GENERAL SAFETY WARNINGS.............................................................................................................. 21
3.2 - SAFETY INSTRUCTIONS ........................................................................................................................ 22
3.2.1 - ELECTROSTATIC DISCHARGES...........................................................................................................22
3.2.2 - CONNECTING TO OTHER DEVICES.....................................................................................................22
3.2.3 - POWER DEVICES .................................................................................................................................22
3.2.4 - SAFETY INSTRUCTIONS FOR INSTALLATION IN HAZARDOUS AREAS...............................................23
3.3 - COMPLIANCE FOR UNITED STATES OF AMERICA................................................................................ 25
3.4 - COMPLIANCE FOR CANADA ................................................................................................................. 25
3.5 - RADIO FREQUENCY EXPOSURE (ACCORDING TO FCC AND ISED) ..................................................... 25
3.6 - PERSONAL PROTECTIVE EQUIPMENT.................................................................................................. 26
3.7 - OBLIGATIONS AND PROHIBITIONS ....................................................................................................... 27
3.8 - RESIDUAL RISKS ................................................................................................................................... 27
3.8.1 - ELECTROSTATIC DISCHARGE RISK ....................................................................................................28
3.9 - SECURITY AND ANTI-FRAUD................................................................................................................. 29
3.10 -SAFETY PICTOGRAMS .......................................................................................................................... 30
3.11 -NOISE LEVEL ......................................................................................................................................... 30

7
SSM-ICON 250
Operation, maintenance and warning manual
STATIC SMART METER |INTRODUCTION | REV . AEN
4 - DESCRIPTION AND OPERATION .................................................................................... 31
4.1 - GENERAL DESCRIPTION ....................................................................................................................... 31
4.1.1 - POWER DEVICES .................................................................................................................................32
4.1.1.1 - CONNECTION OF POWER DEVICES ...........................................................................................32
4.1.1.2 - POWER STATUS ..........................................................................................................................32
4.1.2 - SHUT-OFF VALVE..................................................................................................................................33
4.1.3 - MEASUREMENT ACQUISITION ............................................................................................................34
4.1.4 - DIFFERENTIAL PRESSURE ACQUISITION............................................................................................34
4.1.5 - ACQUISITION OF AMBIENT TEMPERATURE........................................................................................34
4.1.6 - ACQUISITION OF SEISMIC EVENTS.....................................................................................................34
4.1.7 - EVENTS AND DIAGNOSTICS................................................................................................................35
4.1.7.1 - DEVICE DIAGNOSTICS ................................................................................................................35
4.1.8 - ACTIVATION AND CONFIGURATION.....................................................................................................36
4.1.9 - COMMUNICATION INTERFACE ............................................................................................................36
4.1.10 - USER INTERFACE.................................................................................................................................36
4.2 - INTENDED USE ...................................................................................................................................... 37
4.2.1 - INTENDED USE ....................................................................................................................................37
4.2.2 - REASONABLY FORESEEABLE MISUSE ...............................................................................................37
4.3 - TECHNICAL DATA .................................................................................................................................. 38
5 - USER INTERFACE............................................................................................................. 39
5.1 - GENERAL DESCRIPTION ....................................................................................................................... 39
5.2 - DESCRIPTION OF LCD DISPLAY............................................................................................................ 40
5.3 - BROWSING PROCEDURE...................................................................................................................... 42
5.3.1 - MAIN MENU..........................................................................................................................................43
5.3.2 - SECONDARY MENU SELECTION.........................................................................................................44
5.4 - ALARMS ................................................................................................................................................. 45
5.5 - OPENING OF THE SHUT-OFF VALVE...................................................................................................... 45

8
SSM-ICON 250
EN Operation, maintenance and warning manual
STATIC SMART METER |INTRODUCTION | REV . A
6 - TRANSPORT AND HANDLING......................................................................................... 47
6.1 - SPECIFIC WARNINGS FOR TRANSPORT AND HANDLING ................................................................... 47
6.1.1 - PACKAGING AND FASTENING SYSTEMS USED FOR TRANSPORT....................................................47
6.2 - PACKAGE CONTENTS ........................................................................................................................... 48
6.3 - PHYSICAL CHARACTERISTICS OF THE EQUIPMENT ........................................................................... 49
6.4 - METHOD FOR ANCHORING AND LIFTING THE EQUIPMENT................................................................ 50
6.4.1 - FORKLIFT HANDLING METHOD...........................................................................................................51
6.5 - UNPACKING ........................................................................................................................................... 53
6.5.1 - PACKAGING DISPOSAL .......................................................................................................................53
6.6 - STORAGE AND ENVIRONMENTAL CONDITIONS .................................................................................. 54
7 - INSTALLATION .................................................................................................................. 55
7.1 - GENERAL WARNINGS ........................................................................................................................... 55
7.2 - INSTALLATION PRE-REQUISITES........................................................................................................... 55
7.2.1 - ENVIRONMENTAL CONDITIONS ..........................................................................................................55
7.3 - CHECKS BEFORE INSTALLATION.......................................................................................................... 56
7.4 - INSTALLATION-SPECIFIC SAFETY WARNINGS...................................................................................... 57
7.5 - METER INSTALLATION PROCEDURE..................................................................................................... 58
7.6 - ACTIVATION PROCEDURE FOR THE ACQUISITION OF SEISMIC EVENTS ............................................ 59
7.7 - EQUIPMENT ADJUSTMENTS................................................................................................................. 60
8 - CONFIGURATION.............................................................................................................. 61
8.1 - SECURITY REQUIREMENTS FOR CONFIGURATION ............................................................................. 61
8.2 - EQUIPMENT CONFIGURATION .............................................................................................................. 61
8.2.1 - USING THE WIRELESS LOCAL PORT ..................................................................................................61
8.3 - VERIFICATION OF CORRECT CONFIGURATION .................................................................................... 61
8.4 - CONNECTING WITH OTHER DEVICES .................................................................................................. 61
9 - MAINTENANCE AND FUNCTIONAL TESTING ............................................................... 63
9.1 - GENERAL WARNINGS ........................................................................................................................... 63
9.2 - EXTRAORDINARY MAINTENANCE......................................................................................................... 64
9.2.1 - REPLACING THE COMMUNICATION MODULE ....................................................................................64

9
SSM-ICON 250
Operation, maintenance and warning manual
STATIC SMART METER |INTRODUCTION | REV . AEN
10 - UNINSTALLATION AND DISPOSAL ................................................................................. 69
10.1 -GENERAL SAFETY WARNINGS.............................................................................................................. 69
10.2 -QUALIFICATION OF THE OPERATORS IN CHARGE............................................................................... 69
10.3 -UNINSTALLING....................................................................................................................................... 69
10.4 -INFORMATION NEEDED IN CASE OF NEW INSTALLATION ................................................................... 70
10.5 -INFORMATION NEEDED IN CASE OF RE-INSTALLATION ...................................................................... 70
10.6 -DISPOSAL INFORMATION...................................................................................................................... 71
10.6.1 - BATTERY DISPOSAL ............................................................................................................................72
11 - RECOMMENDED SPARE PARTS..................................................................................... 73
11.1 -GENERAL WARNINGS ........................................................................................................................... 73
11.2 -HOW TO REQUEST SPARE PARTS ........................................................................................................ 73
11.3 -SPARE PARTS LIST ................................................................................................................................ 74

10
SSM-ICON 250
EN Operation, maintenance and warning manual
STATIC SMART METER |INTRODUCTION | REV . A

11
SSM-ICON 250
Operation, maintenance and warning manual
STATIC SMART METER |GENERAL INFORMATION |REV. A EN
2 - GENERAL INFORMATION
2.1 - MANUFACTURER IDENTIFICATION
Manufacturer PIETRO FIORENTINI S.P.A.
Address
Via Enrico Fermi, 8/10
36057 Arcugnano (VI) - ITALY
Tel. +39 0444 968511 Fax +39 0444 960468
www.orentini.com sales@orentini.com
Tab. 2.2.
For any problems found on the equipment, contact your gas network distributor.
2.2 - PRODUCT IDENTIFICATION
Equipment STATIC SMART METER
Series SSM-ICON 250
Available models SSM-ICON-250-U7
Tab. 2.3.

12
SSM-ICON 250
EN Operation, maintenance and warning manual
STATIC SMART METER |GENERAL INFORMATION |REV. A
2.3 - REGULATORY FRAMEWORK
PIETRO FIORENTINI S.P.A. with registered ofce in Arcugnano (Italy) - Via E. Fermi, 8/10, declares that the equipment in the
series SSM-ICON 250 that this manual refers to is designed, manufactured, tested and controlled in accordance with the
requirements of the following standards:
• ANSI B109.1
• PS-G-06
• S-G-03 part 1 and part 7
• UL 60079-0, Edition 7, Revision Date 04/15/2020
• CSA C22.2 No. 60079-0, Edition 4, Issue Date 02/2019
• UL 913, Edition 8, Revision Date 05/10/2022
• UL 60079-11, Edition 6, Revision Date 09/14/2018
• CSA C22.2 No. 60079-11, Edition 2, Issue Date 02/2014
• IEC 60079-0, 7th Edition (2017-12) + Corr. 1 (2020-01) + I-SH 01 (2019-04) + I-SH 02 (2019-06),
• IEC 60079-11, 6th Edition (2011-06) + Corr. 1 (2012-01) + I-SH 01 (2014-10) + I-SH 02 (2016-07) + I-SH 03 (2016-07) +
I-SH 04 (2019-04) + I-SH 05 (2019-08) + I-SH 06 (2019-12)
• EN IEC 60079-0:2018
• EN 60079-11:2012.
• UL 50 - Enclosures for Electrical Equipment, Non-Environmental Considerations
• UL 61010-1:2010 - Safety Requirements for Electrical Equipment for Measurement, Control, and
• Laboratory Use - Part 1: General Requirements
• UL 50E - Enclosures for Electrical Equipment, Environmental Considerations
• CSA C22.2 No. 61010-1-12 - Safety Requirements for Electrical Equipment for Measurement,
• Control, and Laboratory Use - Part 1: General Requirements
• CSA C22.2 No. 94.1 - Enclosures for Electrical Equipment, Non-Environmental Considerations
• CSA C22.2 No. 94.2 - Enclosures for Electrical Equipment, Environmental Considerations
For specic approvals see appropriate section on the Manufacturer's website: https://www.orentini.com
2.4 - WARRANTY
PIETRO FIORENTINI S.P.A. guarantees that the equipment has been made with the best materials, with ne workmanship
and complies with the quality requirements, specications and performance envisaged in the order.
The warranty will be considered null and void and PIETRO FIORENTINI S.P.A. will not be responsible for any damage and/or
malfunctions:
• for any acts or omissions of the purchaser or end user, or any of their carriers, employees, agents or any third party or
entity;
• in the event that the purchaser, or a third party, makes changes to the equipment supplied by PIETRO FIORENTINI S.P.A.
without the prior written authorization of the latter;
• in case of non-compliance by the purchaser with the instructions contained in this manual, as supplied by
PIETRO FIORENTINI S.P.A.
The warranty conditions are specied in the commercial contract.

13
SSM-ICON 250
Operation, maintenance and warning manual
STATIC SMART METER |GENERAL INFORMATION |REV. A EN
2.4.1 - REFERENCE OPERATING CONDITIONS
The reference operating conditions for battery life calculation are described in Tab. 2.4:
Operating
condition Reference indications
User interface 15 minutes per month (local interface)
15 minutes per month (Display)
Shut-off
valve 1 handling cycle (opening/closing) each week
Firmware code
update 3 times in 20 years
Communication Version LTE Cat. M1 - Cat. NB2:
• 4 communications per day
Tab. 2.4.
In addition to what is dened in Tab. 2.4, the ambient temperature has an effect on battery life. The operating prole used to
calculate the expected battery life is provided in Tab. 2.5:
Reference indications
Ambient
temperature
1% of the time at -31 °F
2% of the time at -13 °F
3% of the time at -5 °F
5% of the time at +23 °F
15% of the time at +41 °F
50% of the time at +59 °F
15% of the time at +77 °F
5% of the time at +95 °F
3% of the time at +113 °F
1% of the time at +131 °F
Tab. 2.5.

14
SSM-ICON 250
EN Operation, maintenance and warning manual
STATIC SMART METER |GENERAL INFORMATION |REV. A
2.5 - RECIPIENTS, SUPPLY AND CONSERVATION OF THE MANUAL
The manual is intended for the qualied operator responsible and enabled to use and manage the equipment in all its phases
of technical life.
It contains the information necessary for correct use of the equipment, in order to keep its functional and qualitative charac-
teristics unchanged over time. All the information and warnings for correct use in complete safety are also provided.
The manual, like the declaration of conformity and/or test certication, is an integral part of the equipment and must always
accompany it in every transfer or change of ownership. It is the responsibility of licensed professionals (reference paragraph
2.10) to use and operate the equipment.
It is forbidden to remove, rewrite or modify the pages of the manual and their contents.
PIETRO FIORENTINI S.p.A. declines all responsibility for any damage to people, animals and things caused by
failure to observe the warnings and operating methods described in this manual.
2.6 - LANGUAGE
The original manual was written in Italian.
Any translations must be made starting from the original manual.
Language translations cannot be fully veried. If an inconsistency is found, the text of the original manual
must be followed.
If inconsistencies are found or the text is not understandable:
• suspend all action;
• immediately contact PIETRO FIORENTINI S.p.A. at the addresses given in paragraph 2.1 ("Manufacturer's
Identication").
PIETRO FIORENTINI S.p.A. is only responsible for the information contained in the original manual.

15
SSM-ICON 250
Operation, maintenance and warning manual
STATIC SMART METER |GENERAL INFORMATION |REV. A EN
2.7 - SYMBOLS USED IN THE MANUAL
Symbol Denition
Symbol used to identify important warnings for operator and/or equipment safety.
Symbol used to identify particularly important information in the manual.
The information may also concern the safety of personnel involved in using the equipment.
Obligation to consult the instruction manual/booklet.
Indicates a requirement for personnel to consult (and understand) the operating and warning in-
structions of the equipment before working with or on it.
Tab. 2.6.
It signals a hazard with a high level of risk, an imminent hazardous situation that, if not avoided, will cause
death or serious harm.
It signals a hazard with a medium level of risk, a potentially hazardous situation that, if not avoided, could
result in death or serious harm.
It signals a hazard with a low level of risk, a potential hazard situation that, if not avoided, could cause minor
or moderate harm.
It signals specic warnings, directions, or notes of special interest unrelated to physical injury and practices
for which physical injury is not a credible possibility.

16
SSM-ICON 250
EN Operation, maintenance and warning manual
STATIC SMART METER |GENERAL INFORMATION |REV. A
2.8 - IDENTIFICATION PLATES APPLIED
The equipment and its accessories are equipped with identication plates (Id.1 to Id.3).
The plates bear the identication details of the equipment and its accessories to be quoted if necessary to
PIETRO FIORENTINI S.p.A.
List of applied identication plates:
Id. Plate type Image
1Mod. SSM-ICON-250-U7
2Mod. SSM-ICON-250-U7-NTC
Tab. 2.7.
It is absolutely forbidden to remove the identication plates and/or replace them with others.
If, for accidental reasons, the plates are damaged or removed, the customer must inform PIETRO FIORENTINI S.p.A.

17
SSM-ICON 250
Operation, maintenance and warning manual
STATIC SMART METER |GENERAL INFORMATION |REV. A EN
2.8.1 - DEVICE IDENTIFIER
Type Description
METER SERIAL NUMBER Sequential number indicating the identication code of a meter assigned by
the manufacturer.
PURCHASER'S BADGE Sequential number indicating the identication code of a meter assigned by
the customer.
Tab. 2.8.

18
SSM-ICON 250
EN Operation, maintenance and warning manual
STATIC SMART METER |GENERAL INFORMATION |REV. A
2.8.2 - DESCRIPTION OF IDENTIFICATION PLATES
The identication plate bears the information described in Tab. 2.9:
Pos. Description
1Manufacturer's Logo
2Identication of the gas inlet connection
3Static smart meter series.
4Meter class as dened by ANSI B109.1
5Class, Division, and Group as dened by NEC500
6Operating ambient temperature range
7Year of manufacture of the meter
8Reference temperature for volume conversion
9Device serial number (barcode 39)
10 UL le number
11 Maximum operating pressure
12 Device serial number
13 Flow rate of the meter at reference conditions as dened by standard ANSI B109.1
14 Meter model:
• NTC: without temperature compensation (optional)
Tab. 2.9.
Fig. 2.1. Description of identication plates

19
SSM-ICON 250
Operation, maintenance and warning manual
STATIC SMART METER |GENERAL INFORMATION |REV. A EN
2.9 - MEASUREMENT UNIT GLOSSARY
Measurement type Unit of measurement Description
Consumption and
Volumetric ow
Scfh Standard cubic feet per hour
Scf Standard cubic feet
Cfh/h Cubic meters per hour
Cf Cubic feet
Pressure
bar Bar
˝wc Inch of water column
Pa Pascal
Temperature
°C Celsius degree
°F Degree Fahrenheit
K Kelvin
Tightening torque Nm Newton meter
ft-lb Foot pound
Other measurements
V Volt
W Watt
ΩOhm
Tab. 2.10.
2.10 - QUALIFIED PROFESSIONALS
Qualied operators in charge of operating and managing the equipment in all its technical life stages for the use for which it
was supplied:
Professional Denition
Installer
Qualied operator able to:
• handle materials and equipment.
• carry out all the operations necessary for a correct and safe installation of the equipment;
• carry out all the operations necessary for the correct functioning of the equipment and the
system in safety;
• be able to perform all necessary operations for the de-installation and subsequent disposal
of the equipment in accordance with the regulations in the country of installation.

20
SSM-ICON 250
EN Operation, maintenance and warning manual
STATIC SMART METER |GENERAL INFORMATION |REV. A
Professional Denition
Specialized
technician/Maintenance
technician
Trained and licensed technician to operate and manage the equipment who must:
• be able to carry out all the operations necessary for the proper functioning of the equip-
ment and system, guaranteeing their own safety and that of any third parties present;
• perform maintenance activities on all parts of the equipment subject to maintenance (board
and batteries);
• have access to all parts of the device for visual analysis, equipment status checking, ad-
justments and calibrations;
• have proven experience in the correct use of equipment such as those described in this
manual and be trained, informed and instructed accordingly.
Tab. 2.11.
This manual suits for next models
1
Table of contents
Other PIETRO FIORENTINI Measuring Instrument manuals

PIETRO FIORENTINI
PIETRO FIORENTINI SSM-AQUO User manual

PIETRO FIORENTINI
PIETRO FIORENTINI RSE 1,2 LA N1 User manual

PIETRO FIORENTINI
PIETRO FIORENTINI MODUS Series User manual

PIETRO FIORENTINI
PIETRO FIORENTINI SSM-ICON User manual

PIETRO FIORENTINI
PIETRO FIORENTINI IM-RM G10 User manual

PIETRO FIORENTINI
PIETRO FIORENTINI M-LOG Plus User manual

PIETRO FIORENTINI
PIETRO FIORENTINI RSE/2,4 User manual

PIETRO FIORENTINI
PIETRO FIORENTINI SSM-ICON User manual