Pima P-10 User manual

PROTECTOR
Twin Photoelectric Beam Sensors
:Outdoor 33ft.(10m),Indoor 66ft.(20m) (No laser)
PROTECTOR 30:Outdoor 100ft.(30m),Indoor 200ft.(60m) (No laser)
2
3
4
5
6
7
2
3
4
6
6
5
5
INSTALLATION MANUAL
Features:
Range:
PROTECTOR 10
:Outdoor 133ft.(40m),Indoor 266ft.(80m) (With laser)PROTECTOR 40
PROTECTOR 60:Outdoor 200ft.(60m),Indoor 400ft.(120m) (With laser)
PROTECTOR 80:Outdoor 260ft.(80m),Indoor 520ft.(160m) (With laser)
PROTECTOR 120:Outdoor 400ft.(120m),Indoor 800ft.(240m) (With laser)
[COVER] [RECEIVER]
Terminals
Alarm LED
Voltge
Vertical
adjustment
screw
View finder
Mounting Laser
Signal LED
Dela time
adjustment
knob
Horizontal
adjustment
Laser ON/OFF
switch
Lens
Power LED
Tapping screw:4
Mounting Plate:2
2.CAUTIONS ON INSTALLATION
Do Not
Remove all abstructions
(trees,clothes,lines,etc.)
between Transmitter
and Receiver.
Avoid strong light from the sun,
automobile headlights etc.directl
shining on Transmitter/Receiver.
When strong light sta s in optical
axis for a long time,it does not
cause malfunction but will affect
the product life.
Do not install the unit on places
where it ma be splashed b dirt
water or direct sea spra .
Do not install the unit on
unsteady surfaces.
Expansion of beam
The protection distance(between Transmitter
/Receiver)should be placed in the rated range.
Model
PROTECTOR-10
PROTECTOR-30
PROTECTOR-40
PROTECTOR-60
PROTECTOR-80
PROTECTOR-120
10m(33 ft.)
m(100ft.)30
40m(133ft.)
60m(200 ft.)
80m(260 ft.)
120m(400 ft.)
0.6m(2.0 ft.)
0.9m(3.0 ft.)
0.9m(3.0 ft.)
1.8m(6.0 ft.)
2.4m(8.0 ft.)
3.6m(12.0 ft.)
Detection distance Spred of beam
Spred of beam
1.PARTS DESCRIPTION
Twin beam provide reliable perimter security minimizing false
alarms from falling leaves,birds,etc.
Lensed optics reinforce beam strength and provide excellent
immunity to false alarms due to rain,snow,mist,etc.
Weatherproof,sunlight filtering case for indoor and outdoor use.
Anti frost system so that beam functions even in extreme
conditions.
Automatic input power filtering with special noise rejection
circuity.
N.C/N.O. Alarm output.
N.C. Tamper circuit included.
Non polarized power inputs.
Quick,easy installation with built in laser beam alignment
system.
1
3
6.RESPONSE TIME
Adjust response time as follows.The unit does not detect the passing abject faster than the response time set. If the response
time is set longer,the unit does not detect human beings. Adjust to a little longer response time in a site where large passing
objects,newspaper or carton box ma move.
7.TROU LESHOOTING
Trouble
Transmitter LED does not light.
Receiver LED never lights up
when the beam is interupted.
Incorrectl wired and/or insufficient voltage
a.Insufficient voltage
b.Beam reflected awa from receiver
c.Beams not simultaneousl interupted.
Beams interrupted and LED
lights,but no alarm tigger. Alarm tigger cable ma be cut,or the rela
contact stuck due to overloading.
Alarm LED continuousl lit. a.Lenses out of alignment.
b.Beam are blocked.
C.Cover is fogg or dirt .
Alarm tigger becomes erratic
in bad weather. Lenses out of alignment.
Frequent false triggers from
leaves,bird.etc. a.Too sensitive.
b.Bad loccation. a.Reduce the response time.
b.Change the transmitter and/or location.
Ensure the power suppl to the transmitter is
10 to 30 VDC.
a.Double-check the voltage.
b.Clean the cover.
c.Check overall installation.
Check the continuit of the wiring between the
sensor and the alarm.
a.Realign the lenses.
b.Remove an obstacles.
c.Clean the cover.
Check overall s stem installation.If still erratic,
realign the lenses.
Possible Origin(s) Remedy(s)
Model
Max. ragne(outdoor)
P-10
33'(10m) 200'(60m)
Max. ragne(indoor) 66'(20m) 400'(120m)
Current 36mA 42mA 50mA 58mA
Power 10~30VDC(Non polarity)
Detection system 50~700msec(variable)
Alarm output Contact capacity:NC./NO. 1A/120VAC
Tamper output
(Tx & Rx)
NC switch, 1A@120VAC
Alarm LED
(Receiver)
Signal LED
(Receiver)
Power LED
(ReceiverandTransmitter)
Red LED ON:When transmitter and receiver
are not aligned or when beam is broken.
Yellow LED ON:When receiver's signal is
weak or when beam is broken.
Green LED ON:Indicates connected to power.
Laser wavelength 650nm
Laser output power 5mW
Alignment angle Horizontal: 90 , Vertical: 15
Operating temperature
Weight
Case
23 F( 25 C)to +131 F(+55 C)
2.5lbs.(1.1kg)
PC Resin
8.SPECIFICATIONS 9.EXTERNAL DIMENSIONS
4
P-30
260'(80m) 400'(120m)
520'(160m) 800'(240m)
30mA 36mA
133'(40m)
266'(80m)
100'(30m)
200'(60m)
No laser beam alignment :PROTE TOR-10/30
With laser beam alignment :PROTE TOR-40/60/80/120
**
**
Unit: mm
Detection distance
Humidity
<70%
P-40 P-60 P-80 P-120

4
2
3
4
5
6
7
2
3
4
6
6
5
5
2
3
4
5
6
7
2
3
4
6
6
5
5
Wall Mount
(1)Loosen the cover locking screw and remove
the cover.Loosen the unit seting screw at
lower part of unit base. Side the mouning
plate downwards and remove it.
(2)Pull wire through on the installation site.
(3)Break grommet on mounting plate and
pull wire through it.Secure the plate with
mm screws.
Note:Plug opening between grommet
and wire with sealing meterials.
Pull wire through sensor body(back to front)
and attach it to the mounting plate.
( )When exposed wired break knockouts
(2 positions)on the rear of unit,pull
wire through as the figure and attach
it to the mounting plate.
(5)After wiring is completed,adjust
alignment ,cheak operation and
attach cover.
Pole Mount
(6)Do the same procedure as (3)-(5)of wall mount.
(2)Insert 2 pcs.of oval countersunk head screws(M x20)in a pole bracket
with a few rotation.
(3)Fix pole mounting plate to pole with pole bracket.
(1)Use dia 38mm to 5mm pole.
( )Detach cover,and remove mounting plate from sensor body.
(5)Temporily insert 2 pcs of M x10 screws in pole mounting plate and fix
sensor,mounting plate on them.
Pole mounting
plate
Pole breaket
Eyeball adjustment
(1)Remove the transmitter cover, and look into one of the alignment viewfinders
(one of the four holes located between to two lenses)at a 5 angle.
(2)Adjust the horizontal angle of the lens vertically and horizontally unitl the
receiver is clearly seen in the viewfinder.
(3)Repeat steps 1 and 2 for the receiver.
( )Replace the transmitter and receiver covers.
NOTE:If you annot see the opposite unit in the viewfinder,put a sheet of white
paper near the unit to be seen,
Horizontal
adjustment
View
finder
Vertical adjustment
View finder
Laser adjustment Alarm and signal LEDS
Two LEDs OFF
One LED ON
Two LEDs ON
Best
Re-adjust
Good
Signal strength
(1)Remove the transmitter cover, then turn the laser on with
the ON/OFF switch.
(2)Adjust the transmitter's sensor unit verically and horizontally
unti the red dot is centered on the receiver and both the
receiver's LEDs turn off.
(3)Repeat steps 1 and 2 for the receiver.
( )Turn the lasers off,and then replace the covers.
WARNING:Do not look dire tly at the lasers.
Voltage output
5~8V
2.5~5V
1.5~2.5V
Best
Re-adjust
Good
Alignment quality
Fine Tuning the Re eiver
(1)Once the sensor is mounted and aligned,the sensor can
be fine tuned using the voltage output jack.
<1.5V
Fair
(2)Set the range of a volt-ohm meter(VOM)to 0~10VDC.
(3)Mesure the voltge.
( )Adjust the horizontal angle by hand unitl the VOM
iindicates the highest voltage.
(5)Adjust the vertical angle by turning the vertical
adjustment srew until the VOM indicates the highest
voltage.
4.INSTALLATION METHOD
5.ALIGNMENT AND OPERATION
3
Position of installation
The photoelectric beam lens can be adjusted horizontally
, and vertically . This allows much flexibility in
terms of how the transmitterand receiver can be mounted.
Install at a distance of 32" to 39" 80 to 100cm)above the
ground for most situations.
Vertical
adjustment
screw
Horizontal
adjustment
3.WIRING
Wiring
Power
10-30VDC
(non-polarity)
Power
10-30VDC
(non-polarity)
Tamper output N.C.
switch 120V(AC/DC)1A
(When cover detached)
Tamper output N.C.
switch 120V(AC/DC)1A
(When cover detached)
Alarm output
120V(AC/DC)1A
Run a cable from the alarm control panel to the photobeam
sensor.If burying the cable is required,make sure to use
electrical conduit. Shielded cable s strongly suggested.See
table 1 for maximum cable length.
Running the Cable
Note(1):Max.cable length when two or more sets are connected is the
value show in Table 1 divided by the number of sets.
Note(2):The power line be wired to a distnce of up to 3,300 ft.(1,000m)
with AWG22(0.33mm)telephone wire.
Table1:Cable Length
2
Conne tion
Example onne tion 1 - Standard
Power
Alarm signal
Power
Alarm signal
Example onne tion 2 - In-line Single Channel
Example onne tion 2 - Dual Sensors,Separate Channels
Power
Alarm(1ch)
Alarm(2ch)
Transmitter Receiver
Transmitter Receiver Transmitter Receiver
2
2
12V 2 V 12V 2 V 12V 2 V
PROTECTOR-10 PROTECTOR-30 PROTECTOR- 0
12V 2 V 12V 2 V 12V 2 V
PROTECTOR-60 PROTECTOR-80 PROTECTOR-120
Wire/Volt.
360m
600m
1,000m
1,200m
3,200m
5, 00m
8,6 0m
12,000m
320m
550m
800m
980m
2,800m
,800m
7,200m
8,800m
320m
550m
800m
980m
2,800m
,800m
7,200m
8,800m
AWG22
AWG20
AWG18
AWG17
Model No.
Wire/Volt.
AWG22
AWG20
AWG18
AWG17
Model No.
280m
50m
700m
850m
2, 00m
,200m
6,200m
7,600m
110m
170m
250m
310m
900m
1, 00m
2,200m
2,600m
200m
350m
500m
590m
1,600m
3,000m
,200m
5,200m
Transmitter Receiver Transmitter Receiver
This manual suits for next models
5
Other Pima Security Sensor manuals
Popular Security Sensor manuals by other brands

SECOLink
SECOLink BP2 installation manual

Alarmtech
Alarmtech MC 740-E-M14 instruction manual

Summit Treestands
Summit Treestands FBFAHS SU18195-B manual

Pittway
Pittway ECO1005 Installation and maintenance instructions

Honeywell
Honeywell MaxLED Centralized Series quick start guide

Satel
Satel COBALT Pro user manual

SUREN
SUREN M-TEC CDP-808 Installation, operation and specification manual

P3 International
P3 International P7030 user guide

Waygate Technologies
Waygate Technologies Krautkramer USM 10 operating manual

Grasslin
Grasslin talis PF 360-8-2 Operating manual set

B.E.G.
B.E.G. Luxomat PD2-S Operating instruction

Optex
Optex Boundary Gard BX-80NR installation instructions