Pixsys STR550 User manual

STR550
Indicator - Indicatore
User manual - Manuale installatore


Summary
1 Safety guide lines ...................................................................................................................6
2 Model identication..............................................................................................................6
3 Technical Data ........................................................................................................................7
3.1 General data ..............................................................................................................7
4 Hardware data........................................................................................................................7
4.1 Software data............................................................................................................8
5 Dimensions and Installation...............................................................................................9
6 Electrical wirings ................................................................................................................. 10
6.1 Wiring diagram...................................................................................................... 10
7 Display and Key Functions.................................................................................................14
7.1 Keys.............................................................................................................................14
7.2 Display.......................................................................................................................14
8 Controller Functions........................................................................................................... 16
8.1 Memory Card (optional) ...................................................................................... 16
8.2 Modifying alarm thresholds ................................................................................17
8.3 Latch on function....................................................................................................17
8.4 Digital input functions ..........................................................................................19
8.5 Peak values...............................................................................................................19
8.6 Totalizer function................................................................................................... 20
8.7 Sum function........................................................................................................... 20
8.8 Customizable linear input................................................................................... 21
8.9 Alarm Intervention Modes .................................................................................. 21
8.10 Data logger ............................................................................................................. 23
9 Serial communication ....................................................................................................... 24
10 Conguration....................................................................................................................... 28
10.1 Modifying conguration parameters .............................................................. 28
10.2 Loading default values......................................................................................... 28
11 Table of conguration parameters ................................................................................ 29
11.1 Analogue input ...................................................................................................... 29

11.2 V/I custom ................................................................................................................ 33
11.3 Alarm 1 ..................................................................................................................... 37
11.4 Alarm 2 ..................................................................................................................... 40
11.5 Display...................................................................................................................... 42
11.6 Digital input 1......................................................................................................... 43
11.7 Digital input 2......................................................................................................... 44
11.8 Graphic..................................................................................................................... 45
11.9 Analogue output in mA........................................................................................ 46
11.10 Analogue output in Volt....................................................................................... 47
11.11 Comunication port................................................................................................ 48
Sommario
1 Norme di sicurezza ............................................................................................................. 50
2 Identicazione del modello.............................................................................................. 50
3 Dati tecnici ............................................................................................................................ 51
3.1 Caratteristiche generali ....................................................................................... 51
4 Caratteristiche hardware.................................................................................................. 51
4.1 Caratteristiche software ...................................................................................... 52
5 Dimensione e installazione .............................................................................................. 53
6 Collegamenti elettrici......................................................................................................... 54
6.1 Schema di collegamento..................................................................................... 54
7 Funzione dei visualizzatori e tasti................................................................................... 58
7.1 Tasti ........................................................................................................................... 58
7.2 Display...................................................................................................................... 58
8 Funzioni del regolatore ..................................................................................................... 60
8.1 Memory Card (opzionale).................................................................................... 60
8.2 Modica soglie di allarme................................................................................... 61
8.3 Funzione Latch on ................................................................................................. 61
8.4 Funzioni da Ingresso digitale.............................................................................. 63
8.5 Valori di picco.......................................................................................................... 63

8.6 Funzione totalizzatore. ........................................................................................ 64
8.7 Funzione somma ................................................................................................... 64
8.8 Linearizzazione personalizzata......................................................................... 65
8.9 Modi d’intervento allarmi ................................................................................... 65
8.10 Data logger ............................................................................................................. 67
9 Comunicazione Seriale...................................................................................................... 68
10 Congurazione .................................................................................................................... 72
10.1 Modica parametro di congurazione ........................................................... 72
10.2 Caricamento valori di default ............................................................................ 72
11 Tabella parametri di congurazione ............................................................................. 73
11.1 Ingresso analogico................................................................................................ 73
11.2 V/I personalizzato.................................................................................................. 77
11.3 Allarme 1.................................................................................................................. 81
11.4 Allarme 2.................................................................................................................. 84
11.5 Display...................................................................................................................... 86
11.6 Ingresso digitale 1.................................................................................................. 87
11.7 Ingresso digitale 2.................................................................................................. 88
11.8 Graco ...................................................................................................................... 89
11.9 Uscita analogica in mA ........................................................................................ 90
11.10 Uscita analogica in Volt ....................................................................................... 91
11.11 Comunicazione seriale......................................................................................... 92

6 STR550 - User manual
Introduction
Thanks for choosing a Pixsys device.
STR550 is an indicator/panel meter for acquisition and retransmission of processes,
also with fast transient. It is provided with relay outputs for alarm purpose,
analogue outputs for retransmission of process/setpoints and programmable
digital inputs.
Available in standard format 96x48mm, the device can be congured both for
horizontal and vertical mounting.
Distinctive feature is the intuitive multilingual interface, supported by a graphic
LCD display 128x64pixel with backlighting programmable for 7 colors.
Visualization options include bargraph and process trend with programmable
sampling time.
Software features include mathematical functions related to process value like
Totalizer and Sum.
Serial connectivity relies on RS485 and Modbus-RTU protocol.
1 Safety guide lines
Read carefully the safety guidelines and programming instructions contained in
this manual before using/connecting the device. Disconnect power supply before
proceeding to hardware settings or electrical wirings.
Only qualied personnel should be allowed to use the device and/or service it
and in accordance to technical data and environmental conditions listed in this
manual. Do not dispose electric tools together with household waste material.
In observance European Directive 2002/96/EC on waste electrical and electronic
equipment and its implementation in accordance with national law, electric tools
that have reached the end of their life must be collected separately and returned
to an environmentally compatible recycling facility.
2 Model identication
Model .. Vac/Vdc +/-% / Hz – VA
STR-ABC-T
Relays A + out V + out mA + D.I. + RS

User manual - STR550 7
3 Technical Data
3.1 General data
Display Backlighting graphic LCD .”
Operating
temperature
Temperature - °C
Humidity .. uR%
Sealing IP front panel (with gasket)
IP box and terminals
Material Box: Polycarbonate V
Weight Approx. g
4 Hardware data
Power supply
Extended power supply
.. Vac/Vdc ±% /
Hz
Consumption: VA.
Analogue input
AN Congurable via
software.
Thermocouple type K, S,
R, J, T, E, N, B. Automatic
compensation of cold
junction from .. °C.
Thermoresistance: PT,
PT, PT, Ni, PTCK,
NTCK (β K).
Input V/I (linear): - V, -,
- mA, - mV.
Potentiometer input: K,
K.
Tolerance ( °C)
+/-.% ± digit (F.s.) for
thermocouple, thermoresi-
stance and V / mA.
Cold junction accuracy .
°C/°C.
Impedance:
- V: Ri> K
- mA: Ri<
- mA: Ri<
- mV: Ri> M
Relay outputs Relays Contacts A - V~.
Resistive charge.

8 STR550 - User manual
Analogue output
tension
Linear .. Volt.
current
Congurable as output
..mA or ..mA.
All bit +/-.% (F.s.)
4.1 Software data
Regulation
algorithms ON/OFF with hysteresis
Alarm mode
Absolute / Threshold, Band with instantaneous/delayed/
retentive action/by digital input activation, Sensor failure /
Activation by serial line
Sum Function By digital input or by keyboard it is possible to sum dierent
process measurements over time
Totalizer Function Visualisation of instant process value and total value since
last reset
Trend
visualization
Trend visualisation up to samples, with selectable time
basis to s
Analogue
retransmission Process values / Setpoints
Digital
transmission
Process values / Setpoint / Parameters via RS
Latch-on function Semi-automatic setting of limits/ calibration values for
analogue input
Data logging
function
Selectable time basis s to s, tot. memory .k words
Text menus English/Italian/Deutsch/French/Spanish

User manual - STR550 9
5 Dimensions and Installation
Cod. 2100.30.007
Cod. 2100.30.006

10 STR550 - User manual
6 Electrical wirings
Although this controller has been designed to resist noises in an
industrial environment, please notice the following safety guidelines:
t4FQBSBUFDPOUSPMMJOFTGSPNUIFQPXFSXJSFTt"WPJEUIFQSPYJNJUZPGSFNPUFDPOUSPMTXJUDIFTFMFDUSPNBHOFUJDNFUFSTpowerful engines.
t"WPJEUIFQSPYJNJUZPGQPXFSHSPVQTFTQFDJBMMZUIPTFXJUIQIBTFDPOUSPM
6.1 Wiring diagram
+
-
T C
18
12
1711
1610
159
14
8
13
7
R S 4 8 5
P T C
N T C
P T 10 0- N I1 0 0
V /I
+
-
+
-
0V
A O 1
0 /4 . . . 20 m A
+
-
+
-
A O 2
0 . . . 10 V
S U P P L Y
24 . . . 23 0V
A C /D C
6
5
4
3
2
1
Q 1
2A 2 3 0V
R e s is ti v e
1/8 H P
Q 2
2A 2 3 0V
R e s is ti v e
1/8 H P
+2 4 V d c
D I . 1
D I . 2
Power supply
5
SUPPLY
24..230V
AC/DC
6
Switching supply with extended range … Vac/dc ±%
/Hz – VA (galvanic isolated)

User manual - STR550 11
AN analogue imput
13
AI1 TC
14
For thermocouples K, S, R, J, T, E, N, B.
t$PNQMZXJUIQPMBSJUZt'PSQPTTJCMFFYUFOTJPOTVTFBDPNQFOTBUFEXJSFand terminals suitable for the thermocouples used
(compensated).
t8IFOTIJFMEFEDBCMFJTVTFEJUTIPVMECFHSPVOEFEBUPOFside only.
13
AI1
14
PT/Ni100
Shield/Schermo
White/Bianco
Red/Rosso
Red/Rosso
15
For thermoresistances PT, NI.
t'PSUIFUISFFXJSFDPOOFDUJPOVTFXJSFTXJUIUIFTBNFsection.
t'PSUIFUXPXJSFDPOOFDUJPOTIPSUDJSDVJUUFSNJOBMTĊčBOE.
t8IFOTIJFMEFEDBCMFJTVTFEJUTIPVMECFHSPVOEFEBUPOFside only.
13
14
Red/Rosso
White/Bianco
Red/Rosso
15
13
AI1
15
PTC/NTC
Shield/Schermo
For thermoresistances NTC, PTC, PT, PT and
linear potentiometers.
When shielded cable is used, it should be grounded at
one side only to avoid ground loop currents.
13
V/I
+24Vdc
14
10
Shield/Schermo
For linear signals V / mA.
t$PNQMZXJUIQPMBSJUZt8IFOTIJFMEFEDBCMFJTVTFEJUTIPVMECFHSPVOEFEBUPOFside only.

12 STR550 - User manual
Example of connection for linear input Volt and mA
P R E S S U R E T R A N S M I T T E R /
S E N S O R E D I P R E S S I O N E
P :0...100mbar
Pmax :3bar
T :0..70°C
OUT : 4...20mA
IN :9...33V DC
14
13
10
B
C
A
4. .2 0 mA
For linear signals 0/4..20 mA
with three-wire sensor
.
Comply with polarity:
A= Sensor output (+)
B= Sensor ground (-)
C= Sensor power supply (+24Vdc / 35mA)
Ex te rna l su ppl y /
Al im ent az ion e est e rna
P :0...100mbar
Pmax :3bar
T :0..70°C
OUT : 4...20mA
IN :9...33V DC
P R E S S U R E T R A N S M I T T E R /
S E N S O R E D I P R E S S I O N E
14
13
A
B
4. . .2 0 mA
For linear signals 0/4..20 mA
with external power of sensor
.
Comply with polarity:
A= Sensor output (+)
B= Sensor ground (-)
P :0...100mbar
Pmax :3bar
T :0..70°C
OUT : 4...20mA
IN :9...33V DC
10
14
C
A
P R E S S U R E T R A N S M I T T E R /
S E N S O R E D I P R E S S I O N E
4. . 20 m A
For linear signals 0/4..20 mA
with two-wire sensor
.
Comply with polarity:
A= Sensor output
C= Sensor power supply (+24Vdc / 35mA)
Serial input
16
RS485
17
18
Shield/Schermo
RS485 Modbus RTU communication
Relay Q output
3
Q1
2A
230V
1/8Hp
4
Capacity:
2 A / 250 V~ for resistive loads.
NB
: see picture below

User manual - STR550 13
Relay Q output
1
Q2
2A
230V
1/8Hp
2
Capacity:
2A/250 V~ for resistive loads.
NB
: see picture below
Electrical endurance Q1 / Q2.
2 A, 250 Vac, resistive load, 10
5
operations.
20/2 A, 250 Vac, cosφ = 0.3, 10
5
operations.
mA / Volt output
7
AO1
0/4..20mA
8
Pins 7-8
: linear output in
mA
congurable using parameters
as retransmission of process or alarm setpoints (see par.
112-116).
8
AO2
0..10V
9
Pins 8-9
: linear output in
Volt
congurable using parameters
as retransmission of process or alarm setpoints (vedi par.
119-123).
Digital Input
10
11
+24Vdc
DI1
(PnP)
PNP digital input
Digital input according to parameter 95
Short-circuit pins 10 and 11 to activate the digital
input 1

14 STR550 - User manual
Digital input
10
12
+24Vdc
DI2
(PnP)
PNP digital input
Digital input according to parameter 100
Short-circuit pins 10 and 12 to activate the digital
input 2
7 Display and Key Functions
7.1 Keys
Keys are multifunction: in correspondence
of each key its meaning is displayed.
If no description is showed, press a key
to visualize it. Some menus will be only
displayed, when activated.
7.2 Display
It visualizes the process, the setpoints and all conguration parameters. The
programming/ operation interface with text menus in 5 languages makes the
navigation intuitive.
At rst starting, display shows the language
selection.

User manual - STR550 15
This page displays the process, the relays
status and the serial communication (if
available).
This page displays the process, the relays
status and a graph representing the process
trend.
This page displays the process and its
graphic representation as bargraph.

16 STR550 - User manual
8 Controller Functions
8.1 Memory Card (optional)
Parameters and setpoint values can be duplicated from one controller to another
using the Memory card.
2 modes are available:
t
With the controller connected to the power supply:
:
Insert memory card when the controller is o. On activation the LCD visualizes
Load data
and
Esc
in correspondence of the relative keys (only if the correct
values are saved in the memory card). Pressing
Load data
the controller loads the
new values. Pressing
Esc
the device keeps the old values.
t
With the controller not connected to the power supply:
The memory card is equipped with an internal battery with an autonomy of about
1000 uses (2032 button battery, replaceable).
Insert the memory card and press the programming button. When writing the
parameters, led turns red and on completing the procedure it changes to green. It
is possible to repeat the procedure without any particular attention.
NB
: it is not possible to transfer the parameters of a device to one with dierent
code: the LED lights red.
Updating Memory Card
.
To update the memory card values, follow the procedure described on
rst mode, pressing
Esc
so as not to load the parameters on controller.
Enter conguration and change at least one parameter. Exit conguration.
Changes are stored automatically.

User manual - STR550 17
8.2 Modifying alarm thresholds
Selecting one or more absolute/ band alarms, it is possible to modify the
intervention thresholds directly by the user menu, without entering conguration.
Press
Setpoint
to enter the thresholds
modication.
For the modication procedure refer to the following table:
Press Display Do
Sel
Selects the setpoint to be
modied.
Press and to modify
the value. Pressing it is
possible to modify digit per
digit.
Sel
Selects the next setpoint
(if active), otherwise go to
point .
See point .
Sel
and disappear Press
Esc
to exit procedure.
8.3 Latch on function
For the use with input Potentiometers max.6 kohm and Pot.max.150 kohm and
with linear input (0..10 V, 0..60 mV, 0/4..20 mA), it is possible to associate the start
value of the scale (par. 4
Lower limit V/I
) to the minimum position of the sensor
and the value of end scale (par. 5
Upper limit V/I
) to the maximum position of the
sensor.

18 STR550 - User manual
To use the LATCH ON function: enter
conguration, select
Setting
on par. 8
Latch on
and press
Sel
(STR550 shows
the page in the picture).
For the calibration procedure refer to the following table:
Press Display Do
Place the sensor on minimum
operating value (associated
with
Lower limit V/I
).
Set the value on minimum.
Place the sensor on maximum
operating value (associated
with
Upper limit V/I
).
Set the value to maximum.
To exit standard procedure
press
Esc
.
For zero settings place the
sensor on the zero point
0
Set the virtual zero value. Press
Esc
to exit procedure.
Max
Min Zero

User manual - STR550 19
8.4 Digital input functions
On the STR550 model, digital inputs can be enabled by conguring the par. 95
Digital input 1
and the par. 100
Digital Input 2.
t
Run
: allows the action of relays and linear output.
t
Hold
: locks the conversion.
t
Tare zero (AI)
: selects to zero the process value (tare function).
t
Alarm reset:
if one or more alarms are selected with manual reset and alarm
conditions are no longer present, closing the digital input it is possible to
restore the alarm output.
t
Totalizer reset
: if the totalizer function is active, using the digital input it is
possible to reset the counter.
t
Peaks reset
: min. peak/max. peak/peak-to-peak values are reset.
t
Sum total
: if the sum function is active, using the digital input it is possible to
increase the “sum” counter as indicated by the process value.
t
Sum reset
: if the sum function is active, using the digital input it is possible to
reset the “sum” counter.
t
Cong. lock
: if the digital input is active it is not possible to enter conguration
or to modify the setpoints.
Selecting
Digital input 1
or
Digital input 2
on the alarm parameters, the related
relays will activate togheter with the digital input; functions selected on
parameters 95 and 100 will continue to work.
8.5 Peak values
The STR550 is provided with a page for
the visualization of peak values: max.
peak, min. peak and peak-to-peak of
analogue input. Keeping pressed
Rst
it
is possible to reset the visualized values.

20 STR550 - User manual
8.6 Totalizer function
The totalizer function, which can be enable by par. 9
Totalizer,
performs an instant
measurement of the process and sums it on a time basis to the previously totalized
value.
On the dedicated page it is possible to
see the instant process value and the
totalized value: keeping pressed
Rst
it is
possible to reset this value.
Ex.: if a sensor 4..20mA with F.s. 9000m
3
/hour is connected, it is necessary to select
Hour
on par. 9
Totalizer.
The device will increase the totalized value considering
the m
3
owing each second (2.5m
3
).
8.7 Sum function
The sum function, which can be enabled by par. 10
Sum function,
allows to increase
a counter adding the process value on command. It is an application typical for
weighing systems and allows to know the total weighed value.
Press
Sum Function
to enter the
function page. Pressing
+
the
Process
value is added to the counter. It is
possible to reset the total value keeping
pressed
Rst
and to x “tare zero” of the
process pressing
Tar
.
Functions tare, sum and reset can be managed also by digital input if enabled on
par. 95
Digital Input 1
and par. 100
Digital Input 2
.
This manual suits for next models